Wiki source code of AV Integration

Version 7.1 by Craig Lewis on 2020/08/18 17:44

Hide last authors
Craig Lewis 5.1 1 AV Integration - EISC (Remote Connections)
Craig Lewis 4.1 2
Craig Lewis 5.1 3 * Creating Remote Connections through the UI
4 ** Open the Setting (Gear icon in upper right corner) screen from the main page
5 ** Select Crestron Integration
6 ** To add and edit a new connection:
7 *** press the + Add at the bottom left corner of the page
8 *** In the left column select the connection you want to edit
Craig Lewis 6.1 9 *** In the middle column enter:
10 **** Connection label
11 **** IP Address of the AV Processor
12 **** IP ID
Craig Lewis 5.1 13 *** Additional features can be selected:
14 **** Ignore Fade Times
15 **** Extended Load Export
16 **** Extended Scene Export
17 *** EISC Type:
18 **** Classic (2-Series Compatible)
19 **** 3-series TCP EISC
20 *** In the right column select all areas needed
21 *** Save by clicking on the Check mark that appears to the right or "Settings:" in the middle column
22 *** Saving will generate an RSD File URL at the bottom of the middle column
Craig Lewis 6.1 23 **** http:~/~/10.0.0.10/ShowRunner/RSDs/IP-ID0xF1Lighting_Interface.rsd
24 **** 10.0.0.10 = Lighting system Processor IP Address
25 **** IP-ID0xF1 = Lighting system Processor IP Table entry for AV integration
Craig Lewis 5.1 26 *** RSD file can also be retrieved from the Toolbox File Manager app
27 **** Open File Manager
28 **** Select Internal Flash/HTML/ShowRunner/RSDs
29 **** all generated RSD files will be available in this folder
Craig Lewis 4.1 30
Craig Lewis 5.1 31 AV Integration - RS-232
Craig Lewis 4.1 32
Craig Lewis 3.1 33 * [[attach:CI ShowRunner RS-232 Spec.pdf||target="_blank"]]