Changes for page *ZUMNET-JBOX Load Controllers
Last modified by Alexander Mott on 2024/01/05 18:55
To version 38.1
edited by Alexander Mott
on 2022/06/22 18:31
on 2022/06/22 18:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,15 @@ 1 +{{box title="**Contents**"}} 2 +{{toc/}} 3 +{{/box}} 4 + 1 1 (% class="row" %) 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 - ZUMNET-JBOXdevices are distributed lighting controllers that comprise the networked portion of aZūmWired system.Typically, each room will have just one ZUMNET-JBOXdevicethat connectsto the [[Zūm Net>>SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome||anchor="HZ16BmNet"]] lighting network and may optionally host one or more [[Zūm Link>>SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome||anchor="HZ16BmLink"]] devices. All diagrams on this page are from Crestron's [[official quick start guide>>https://cf-store.widencdn.net/crestron/6/2/a/62a56919-3bf4-43d7-9a9d-0647f497846c.pdf?response-content-disposition=inline%3B%20filename%3D%22mg_qs_zumnet-jbox.pdf%22&Expires=1655926244&Signature=GmTN1TAWCWbuAVCqKKodfwZWuc1XYqZKTpLL~~ZStDYoF1xxK9KHfh6fzrF88A2ZhWy~~1QUplW3N7mfz4Vt3hseXwd3S7RPSFjNxfzOzNKIRM2noeWBDT5DQYhlZYwsD7IxusuwQrxjbkH-CwKt-OlgK~~SeSTJWTbQnCwYIdR-cOfbD2R3ST~~3sipKDnPNz5OKmMsfhnFlHamGk9yeyMOvpcjJYL0IB1p4saJrnkuIrgH1m29HyKOjlhpDE7JRyAx0LK0zy7ZrZoP7SkdGld5Yv1gO3zQZP5ZBiM8l5TEVbX11Gf0eKRqlRarfBq49dLaexVdfUAtrGsyrMOP0mhsJw__&Key-Pair-Id=APKAJD5XONOBVWWOA65A]] ([[mirror>>attach:mg_qs_zumnet-jbox.pdf]]).9 += Zūm Net JBOX Devices = 6 6 11 +ZUMNET-JBOX devices are distributed lighting controllers that comprise the networked portion of a Zūm Wired system. Typically, each room will have just one ZUMNET-JBOX device that connects to the [[Zūm Net>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmNet"]] lighting network and may optionally host one or more [[Zūm Link>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmLink"]] devices. All diagrams on this page are from Crestron's [[official quick start guide>>https://cf-store.widencdn.net/crestron/6/2/a/62a56919-3bf4-43d7-9a9d-0647f497846c.pdf?response-content-disposition=inline%3B%20filename%3D%22mg_qs_zumnet-jbox.pdf%22&Expires=1655926244&Signature=GmTN1TAWCWbuAVCqKKodfwZWuc1XYqZKTpLL~~ZStDYoF1xxK9KHfh6fzrF88A2ZhWy~~1QUplW3N7mfz4Vt3hseXwd3S7RPSFjNxfzOzNKIRM2noeWBDT5DQYhlZYwsD7IxusuwQrxjbkH-CwKt-OlgK~~SeSTJWTbQnCwYIdR-cOfbD2R3ST~~3sipKDnPNz5OKmMsfhnFlHamGk9yeyMOvpcjJYL0IB1p4saJrnkuIrgH1m29HyKOjlhpDE7JRyAx0LK0zy7ZrZoP7SkdGld5Yv1gO3zQZP5ZBiM8l5TEVbX11Gf0eKRqlRarfBq49dLaexVdfUAtrGsyrMOP0mhsJw__&Key-Pair-Id=APKAJD5XONOBVWWOA65A]] ([[mirror>>attach:mg_qs_zumnet-jbox.pdf]]). 12 + 7 7 All ZUMNET-JBOXs have two purple ZUMNET (LAN) ports and two orange ZUMLINK (ROOM) ports: 8 8 9 9 * One ZUMNET (LAN) port should come from the previous Zūm Net device or a Hub panel ... ... @@ -15,12 +15,12 @@ 15 15 16 16 In //[[Figure 1>>WebHome||anchor="HFigure1"]]//, ZUMLINK ports are shown in orange, ZUMNET ports are shown in purple, and the sensor input block is between them. 17 17 18 -= ZUMNET-JBOX-16A-LV Wiring = 24 +== ZUMNET-JBOX-16A-LV Wiring == 19 19 20 20 The ZUMNET-JBOX-16A-LV attaches to a standard 4" or 4-11/16" junction box through a 1/2" knockout. High voltage AC and 0-10V dimming splices are made inside of the junction box, while low-voltage Zūm Net, Zūm Link, and non-system sensor connections are made outside of the junction box. 21 21 //[[Figure 2>>WebHome||anchor="HFigure2"]]// 22 22 23 -= ZUMNET-JBOX-DALI Wiring = 29 +== ZUMNET-JBOX-DALI Wiring == 24 24 25 25 L 26 26 //[[Figure 3>>WebHome||anchor="HFigure3"]]// ... ... @@ -27,18 +27,14 @@ 27 27 28 28 The official quick start guide from Crestron is available [[here>>attach:mg_qs_zumnet-jbox.pdf]]. 29 29 30 -= Sensor Input Wiring Detail = 36 +== Sensor Input Wiring Detail == 31 31 32 - {{displayexcludeFirstHeading="true"reference="SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.LoadControllers(ZUMLINK-JBOX).WebHome" section="HSensorInputWiringDetail"/}}38 +Non-system sensors (including Crestron GLS-ODT-C-NS sensors, GLA-LDL photocells, and Steinel occupancy sensors) may be landed at the sensor input terminal block of ZUMNET-JBOX devices. Details on the sensor input wiring can be found [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Sensor Input Detail (ZUMNET- and ZUMLINK-JBOX).WebHome]]. 33 33 ))) 34 34 35 35 36 36 (% class="col-xs-12 col-sm-4" %) 37 37 ((( 38 -{{box title="**CONTENTS**"}} 39 -{{toc/}} 40 -{{/box}} 41 - 42 42 (% class="wikigeneratedid" id="HFigure1" %) 43 43 ((( 44 44 [[[[image:wiki_znet over trans.png]]>>attach:wiki_znet over trans.png]]