Changes for page *ZUMNET-JBOX Load Controllers
Last modified by Alexander Mott on 2024/01/05 18:55
From version 33.2
edited by Alexander Mott
on 2022/03/30 16:17
on 2022/03/30 16:17
Change comment:
Update document after refactoring.
To version 38.1
edited by Alexander Mott
on 2022/06/22 18:31
on 2022/06/22 18:31
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -ZUMNET-JBOX Load Controllers 1 +*ZUMNET-JBOX Load Controllers - Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - false1 +true - Content
-
... ... @@ -8,7 +8,7 @@ 8 8 ((( 9 9 = Zūm Net JBOX Devices = 10 10 11 -ZUMNET-JBOX devices are distributed lighting controllers that comprise the networked portion of a Zūm Wired system. Typically, each room will have just one ZUMNET-JBOX device that connects to the [[Zūm Net>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmNet"]] lighting network and may optionally host one or more [[Zūm Link>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmLink"]] devices. 11 +ZUMNET-JBOX devices are distributed lighting controllers that comprise the networked portion of a Zūm Wired system. Typically, each room will have just one ZUMNET-JBOX device that connects to the [[Zūm Net>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmNet"]] lighting network and may optionally host one or more [[Zūm Link>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmLink"]] devices. All diagrams on this page are from Crestron's [[official quick start guide>>https://cf-store.widencdn.net/crestron/6/2/a/62a56919-3bf4-43d7-9a9d-0647f497846c.pdf?response-content-disposition=inline%3B%20filename%3D%22mg_qs_zumnet-jbox.pdf%22&Expires=1655926244&Signature=GmTN1TAWCWbuAVCqKKodfwZWuc1XYqZKTpLL~~ZStDYoF1xxK9KHfh6fzrF88A2ZhWy~~1QUplW3N7mfz4Vt3hseXwd3S7RPSFjNxfzOzNKIRM2noeWBDT5DQYhlZYwsD7IxusuwQrxjbkH-CwKt-OlgK~~SeSTJWTbQnCwYIdR-cOfbD2R3ST~~3sipKDnPNz5OKmMsfhnFlHamGk9yeyMOvpcjJYL0IB1p4saJrnkuIrgH1m29HyKOjlhpDE7JRyAx0LK0zy7ZrZoP7SkdGld5Yv1gO3zQZP5ZBiM8l5TEVbX11Gf0eKRqlRarfBq49dLaexVdfUAtrGsyrMOP0mhsJw__&Key-Pair-Id=APKAJD5XONOBVWWOA65A]] ([[mirror>>attach:mg_qs_zumnet-jbox.pdf]]). 12 12 13 13 All ZUMNET-JBOXs have two purple ZUMNET (LAN) ports and two orange ZUMLINK (ROOM) ports: 14 14 ... ... @@ -19,25 +19,23 @@ 19 19 20 20 It is important to note that while there are two ZUMLINK ports, Zūm Link runs should never be looped back to a ZUMNET-JBOX. Zūm Link runs should originate at a ZUMNET-JBOX, connect to a number of Zūm Link devices, and then stop at the last Zūm Link device. The reason for having multiple ZUMLINK ports is ease of installation; for example, if there are two ZUMLINK-KP keypads in a room, it might be easier to put them at the end of two separate runs so that only one RJ-45 terminated Zūm Link cable needs to be pulled through conduit. 21 21 22 -In //[[Figure 1>> xwiki:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome||anchor="HFigure1"]]//, ZUMLINK ports are shown in orange, ZUMNET ports are shown in purple, and the sensor input block is between them.22 +In //[[Figure 1>>WebHome||anchor="HFigure1"]]//, ZUMLINK ports are shown in orange, ZUMNET ports are shown in purple, and the sensor input block is between them. 23 23 24 24 == ZUMNET-JBOX-16A-LV Wiring == 25 25 26 26 The ZUMNET-JBOX-16A-LV attaches to a standard 4" or 4-11/16" junction box through a 1/2" knockout. High voltage AC and 0-10V dimming splices are made inside of the junction box, while low-voltage Zūm Net, Zūm Link, and non-system sensor connections are made outside of the junction box. 27 -//[[Figure 2>> xwiki:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome||anchor="HFigure2"]]//27 +//[[Figure 2>>WebHome||anchor="HFigure2"]]// 28 28 29 -The official quick start guide from Crestron is available [[here>>attach:mg_qs_zumnet-jbox.pdf]]. 30 - 31 31 == ZUMNET-JBOX-DALI Wiring == 32 32 33 33 L 34 -//[[Figure 3>> xwiki:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome||anchor="HFigure3"]]//32 +//[[Figure 3>>WebHome||anchor="HFigure3"]]// 35 35 36 36 The official quick start guide from Crestron is available [[here>>attach:mg_qs_zumnet-jbox.pdf]]. 37 37 38 38 == Sensor Input Wiring Detail == 39 39 40 -Non-system sensors (including Crestron GLS-ODT-C-NS sensors, GLA-LDL photocells, and Steinel occupancy sensors) may be landed at the sensor input terminal block of ZUMNET-JBOX devices. Details on the sensor input wiring can be found [[here>>doc:Wiring Guide.Zūm Wired System Overview.Sensor Input Detail (ZUMNET- and ZUMLINK-JBOX).WebHome]]. 38 +Non-system sensors (including Crestron GLS-ODT-C-NS sensors, GLA-LDL photocells, and Steinel occupancy sensors) may be landed at the sensor input terminal block of ZUMNET-JBOX devices. Details on the sensor input wiring can be found [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Sensor Input Detail (ZUMNET- and ZUMLINK-JBOX).WebHome]]. 41 41 ))) 42 42 43 43