Last modified by Alexander Mott on 2024/01/05 18:55

From version 28.1
edited by Alexander Mott
on 2021/12/29 23:35
Change comment: There is no comment for this version
To version 34.1
edited by Alexander Mott
on 2022/03/30 16:17
Change comment: Renamed back-links.

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Wiring Guide.Zūm Wired System Overview.WebHome
1 +SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.WebHome
Content
... ... @@ -8,7 +8,7 @@
8 8  (((
9 9  = Zūm Net JBOX Devices =
10 10  
11 -ZUMNET-JBOX devices are distributed lighting controllers that comprise the networked portion of a Zūm Wired system. Typically, each room will have just one ZUMNET-JBOX device that connects to the [[Zūm Net>>xwiki:Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmNet"]] lighting network and may optionally host one or more [[Zūm Link>>xwiki:Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmLink"]] devices.
11 +ZUMNET-JBOX devices are distributed lighting controllers that comprise the networked portion of a Zūm Wired system. Typically, each room will have just one ZUMNET-JBOX device that connects to the [[Zūm Net>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmNet"]] lighting network and may optionally host one or more [[Zūm Link>>SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmLink"]] devices.
12 12  
13 13  All ZUMNET-JBOXs have two purple ZUMNET (LAN) ports and two orange ZUMLINK (ROOM) ports:
14 14  
... ... @@ -19,17 +19,19 @@
19 19  
20 20  It is important to note that while there are two ZUMLINK ports, Zūm Link runs should never be looped back to a ZUMNET-JBOX. Zūm Link runs should originate at a ZUMNET-JBOX, connect to a number of Zūm Link devices, and then stop at the last Zūm Link device. The reason for having multiple ZUMLINK ports is ease of installation; for example, if there are two ZUMLINK-KP keypads in a room, it might be easier to put them at the end of two separate runs so that only one RJ-45 terminated Zūm Link cable needs to be pulled through conduit.
21 21  
22 -In //[[Figure 1>>xwiki:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome||anchor="HFigure1"]]//, ZUMLINK ports are shown in orange, ZUMNET ports are shown in purple, and the sensor input block is between them.
22 +In //[[Figure 1>>WebHome||anchor="HFigure1"]]//, ZUMLINK ports are shown in orange, ZUMNET ports are shown in purple, and the sensor input block is between them.
23 23  
24 24  == ZUMNET-JBOX-16A-LV Wiring ==
25 25  
26 -Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
26 +The ZUMNET-JBOX-16A-LV attaches to a standard 4" or 4-11/16" junction box through a 1/2" knockout. High voltage AC and 0-10V dimming splices are made inside of the junction box, while low-voltage Zūm Net, Zūm Link, and non-system sensor connections are made outside of the junction box.
27 +//[[Figure 2>>WebHome||anchor="HFigure2"]]//
27 27  
28 28  The official quick start guide from Crestron is available [[here>>attach:mg_qs_zumnet-jbox.pdf]].
29 29  
30 30  == ZUMNET-JBOX-DALI Wiring ==
31 31  
32 -Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
33 +L
34 +//[[Figure 3>>WebHome||anchor="HFigure3"]]//
33 33  
34 34  The official quick start guide from Crestron is available [[here>>attach:mg_qs_zumnet-jbox.pdf]].
35 35  
... ... @@ -45,12 +45,14 @@
45 45  (((
46 46  [[[[image:wiki_znet over trans.png]]>>attach:wiki_znet over trans.png]]
47 47  //Figure 1: ZUMNET-JBOX Overview [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Z%C5%ABm%20Wired%20System%20Overview/Load%20Controllers%20%28ZUMNET-JBOX%29/WebHome/wiki_znet%20over%20trans.png?rev=1.1]]//
48 -))))
50 +)))
51 +
49 49  (% class="wikigeneratedid" id="HFigure2" %)
50 50  (((
51 51  [[[[image:wiki_znetlv trans.png]]>>attach:wiki_znetlv trans.png]]
52 52  //Figure 2: ZUMNET-JBOX-16A-LV Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Z%C5%ABm%20Wired%20System%20Overview/Load%20Controllers%20%28ZUMNET-JBOX%29/WebHome/wiki_znetlv%20trans.png?rev=1.1]]//
53 53  )))
57 +
54 54  (% class="wikigeneratedid" id="HFigure3" %)
55 55  (((
56 56  [[[[image:wiki_znetdali trans.png]]>>attach:wiki_znetdali trans.png]]