... ... @@ -4,16 +4,20 @@
4 4  
5 5  |(% style="width:350px" %)**Command**|(% style="width:1139px" %)**Description**
6 6  |(% style="width:350px" %)##autodiscovery query##|(% style="width:1139px" %)Will generate a list of all network devices (Must be connected to one of your processors)
7 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##detlev## [0-15]|(% style="width:1139px" %)Will set Detection Level 0-15 (Sensitivity in the App)
8 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##detrang## [0-255]|(% style="width:1139px" %)Will set Detection Range 0-255
9 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##setir off## (or on)|(% style="width:1139px" %)Will disable/enable IR on ZUMLINK-Occupancy Sensor with IR technology
10 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##setus off## (or on)|(% style="width:1139px" %)Will disable/enable US on ZUMLINK-Occupancy Sensor with US technology
11 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##setto ##[5-1800]|(% style="width:1139px" %)Will set timeout in seconds for the ZUMLINK-Occupancy Sensor
12 12  |(% style="width:350px" %)##who##|(% style="width:1139px" %)Will generate a list of all online network devices (Must be connected to one of your processors)
8 +|(% style="width:350px" %)**ZUMNET-JBOX**|(% style="width:1139px" %)
13 13  |(% style="width:350px" %)##zwms##|(% style="width:1139px" %)Tell which mode the ZUMNET-JBOX is in
14 14  |(% style="width:350px" %)##zwms master## (or ##slave##)|(% style="width:1139px" %)Will set mode for ZUMNET-JBOX (old firmware)
15 15  |(% style="width:350px" %)##zwps primary## (or ##secondary##)|(% style="width:1139px" %)Will set mode for ZUMNET-JBOX (newer firmware)
16 16  |(% style="width:350px" %)##zwmode##|(% style="width:1139px" %)Will tell if your ZUMNET-JBOX is setup for Zum or Cresnet
17 -|(% style="width:350px" %)##zwmode zum## (or ##cnet##)|(% style="width:1139px" %)Will set your Zum Op mode for your ZUMNET-JBOX
13 +|(% style="width:350px" %)##zwmode zum## (or ##cnet##)|(% style="width:1139px" %)(((
14 +Will set your Zum Op mode for your ZUMNET-JBOX
15 +)))
16 +|(% style="width:350px" %)**ZUMLINK-OCC-VAC-SENSORS**|(% style="width:1139px" %)
17 +|(% style="width:350px" %)##rcon 1.##[//CID//] ##detlev## [0-15]|(% style="width:1139px" %)Will set Detection Level 0-15 (Sensitivity in the App)
18 +|(% style="width:350px" %)##rcon 1.##[//CID//] ##detrang## [0-255]|(% style="width:1139px" %)Will set Detection Range 0-255
19 +|(% style="width:350px" %)##rcon 1.##[//CID//] ##setir off## (or on)|(% style="width:1139px" %)Will disable/enable IR on ZUMLINK-Occupancy Sensor with IR technology
20 +|(% style="width:350px" %)##rcon 1.##[//CID//] ##setus off## (or on)|(% style="width:1139px" %)Will disable/enable US on ZUMLINK-Occupancy Sensor with US technology
21 +|(% style="width:350px" %)##rcon 1.##[//CID//] ##setto ##[5-1800]|(% style="width:1139px" %)Will set timeout in seconds for the ZUMLINK-Occupancy Sensor
18 18  