Changes for page Zum Wired
Last modified by Craig Lewis on 2024/07/15 20:18
From version 16.1
edited by Craig Lewis
on 2024/05/22 16:47
on 2024/05/22 16:47
Change comment:
There is no comment for this version
To version 7.1
edited by Craig Lewis
on 2024/05/22 14:41
on 2024/05/22 14:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,21 +4,16 @@ 4 4 5 5 |(% style="width:350px" %)**Command**|(% style="width:1139px" %)**Description** 6 6 |(% style="width:350px" %)##autodiscovery query##|(% style="width:1139px" %)Will generate a list of all network devices (Must be connected to one of your processors) 7 -|(% style="width:350px" %) ##who##|(% style="width:1139px" %)Willgeneratea listf all onlinenetwork devices(Mustbeconnectedtooneof yourprocessors)8 -|(% style="width:350px" %) **ZUMNET-JBOX**|(% style="width:1139px" %)9 -|(% style="width:350px" %) ##zwmode##|(% style="width:1139px" %)WilltellifyourZUMNET-JBOX is setupfor Zum or Cresnet (Newer firmware will also displaymodeand autoswitch enable/disable)10 -|(% style="width:350px" %) ##zwmodezum##(or##cnet##)|(% style="width:1139px" %)(((11 -Will set yourZumOp modeforyourZUMNET-JBOX12 -))) 7 +|(% style="width:350px" %)rcon 1.[//CID//] detlev [0-15]|(% style="width:1139px" %)Will set Detection Level 0-15 (Sensitivity in the App) 8 +|(% style="width:350px" %)rcon 1.[//CID//] detrang [0-255]|(% style="width:1139px" %)Will set Detection Range 0-255 9 +|(% style="width:350px" %)rcon 1.[//CID//] setir disable (or enable)|(% style="width:1139px" %)Will disable/enable IR on ZUMLINK-Occupancy Sensor with IR technology 10 +|(% style="width:350px" %)rcon 1.[//CID//] setus disable (or enable)|(% style="width:1139px" %)Will disable/enable US on ZUMLINK-Occupancy Sensor with US technology 11 +|(% style="width:350px" %)rcon 1.[//CID//] setto [timeout]|(% style="width:1139px" %)Will set timeout in seconds for the ZUMLINK-Occupancy Sensor 12 +|(% style="width:350px" %)who|(% style="width:1139px" %)Will generate a list of all online network devices (Must be connected to one of your processors) 13 13 |(% style="width:350px" %)##zwms##|(% style="width:1139px" %)Tell which mode the ZUMNET-JBOX is in 14 14 |(% style="width:350px" %)##zwms master## (or ##slave##)|(% style="width:1139px" %)Will set mode for ZUMNET-JBOX (old firmware) 15 15 |(% style="width:350px" %)##zwps primary## (or ##secondary##)|(% style="width:1139px" %)Will set mode for ZUMNET-JBOX (newer firmware) 16 -|(% style="width:350px" %)##autoswitch on## (or off)|(% style="width:1139px" %)Will enable/disable Autoswitch mode for ZUMNET-JBOX 17 -|(% style="width:350px" %)**ZUMLINK-OCC-VAC-SENSORS**|(% style="width:1139px" %) 18 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##detlev## [0-15]|(% style="width:1139px" %)Will set Detection Level 0-15 (Sensitivity in the App) 19 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##detrang## [0-255]|(% style="width:1139px" %)Will set Detection Range 0-255 20 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##setir off## (or on)|(% style="width:1139px" %)Will disable/enable IR on ZUMLINK-Occupancy Sensor with IR technology 21 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##setus off## (or on)|(% style="width:1139px" %)Will disable/enable US on ZUMLINK-Occupancy Sensor with US technology 22 -|(% style="width:350px" %)##rcon 1.##[//CID//] ##setto ##[5-1800]|(% style="width:1139px" %)Will set timeout in seconds for the ZUMLINK-Occupancy Sensor 16 +|(% style="width:350px" %)##zwmode##|(% style="width:1139px" %)Will tell if your ZUMNET-JBOX is setup for Zum or Cresnet 17 +|(% style="width:350px" %)##zwmode zum## (or ##cnet##)|(% style="width:1139px" %)Will set your Zum Op mode for your ZUMNET-JBOX 23 23 24 24