author | version | line-number | content |
---|---|---|---|
![]() |
11.2 | 1 | Older systems with GLPACs wired back to the processor via Cresnet can be added by created a program for slot 2. |
![]() |
7.1 | 2 | |
3 | |||
![]() |
11.2 | 4 | * Create a SIMPL windows program |
5 | * Add the GLPAC-DIMFLV8 (Cresnet) to the appropriate Cresnet IDs | ||
6 | * Define the Level In and Level Out analog signals on each of the GLPAC Remote Standard Intersystem Communications | ||
![]() |
7.1 | 7 | |
![]() |
11.2 | 8 | [[image:1660773651340-476.png]] |
![]() |
7.1 | 9 | |
![]() |
11.3 | 10 | * Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID |
11 | * In Device Settings, set the Default IP Address to 127.0.0.2 (Loop back address) | ||
![]() |
7.1 | 12 | |
![]() |
11.3 | 13 | [[image:image-20220817145415-2.png]] |
14 | |||
15 | * Copy the GLPACs Level In and Level Out signals and paste them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals | ||
16 | |||
![]() |
11.1 | 17 | [[image:1660773665229-324.png]] |
![]() |
7.1 | 18 | |
19 | |||
![]() |
11.2 | 20 | |
![]() |
7.1 | 21 | [[image:image-20220817145415-4.png]] |