Wiki source code of GLPAC (Cresnet)

Version 11.3 by Craig Lewis on 2022/08/18 16:52

Hide last authors
Craig Lewis 11.2 1 Older systems with GLPACs wired back to the processor via Cresnet can be added by created a program for slot 2.
Craig Lewis 7.1 2
3
Craig Lewis 11.2 4 * Create a SIMPL windows program
5 * Add the GLPAC-DIMFLV8 (Cresnet) to the appropriate Cresnet IDs
6 * Define the Level In and Level Out analog signals on each of the GLPAC Remote Standard Intersystem Communications
Craig Lewis 7.1 7
Craig Lewis 11.2 8 [[image:1660773651340-476.png]]
Craig Lewis 7.1 9
Craig Lewis 11.3 10 * Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID
11 * In Device Settings, set the Default IP Address to 127.0.0.2 (Loop back address)
Craig Lewis 7.1 12
Craig Lewis 11.3 13 [[image:image-20220817145415-2.png]]
14
15 * Copy the GLPACs Level In and Level Out signals and paste them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals
16
Craig Lewis 11.1 17 [[image:1660773665229-324.png]]
Craig Lewis 7.1 18
19
Craig Lewis 11.2 20
Craig Lewis 7.1 21 [[image:image-20220817145415-4.png]]