Wiki source code of ZUM-HUB4 Processor Setup

Version 34.1 by Alexander Mott on 2023/12/12 00:01

Hide last authors
Alexander Mott 1.2 1 (% class="box errormessage" %)
Alexander Mott 1.1 2 (((
Alexander Mott 1.2 3 This page is for ZUM-HUB4 deployments. For other processors, see our [[normal processor setup page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome]].
Alexander Mott 1.1 4 )))
5
Alexander Mott 33.1 6 (% class="box errormessage" %)
7 (((
8 **IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself.
9 )))
10
Alexander Mott 1.2 11 (% class="box warningmessage" %)
Alexander Mott 1.1 12 (((
Alexander Mott 27.1 13 ZUM-HUB4 requires firmware version 2.006.0034 or greater for third party software to be loaded.
14 (Once installed, running the "##ver##" command should report a FW version of 2.8000.00009 or greater.)
Alexander Mott 1.1 15 )))
16
Alexander Mott 20.1 17 {{box cssClass="floatinginfobox" title="**CONTENTS**"}}
Alexander Mott 12.1 18 {{toc/}}
19 {{/box}}
20
Alexander Mott 1.1 21 **Licensing tutorial:**
22
23 //Note: Please use Chrome or Firefox to download the License from [[https:~~/~~/portal.chiefintegrations.com>>https://portal.chiefintegrations.com]].  Edge and Internet Explorer do not work properly.//
24
25 [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]]
26
Alexander Mott 29.1 27 {{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HErrorBroadcasting"/}}
28
Alexander Mott 12.1 29 = IP Configuration and Console Commands =
Alexander Mott 1.1 30
Alexander Mott 1.2 31 * Connect to the ZUM-HUB4 via USB and create an admin-level CWS user
32 ** Input the desired username and password into the dialog box. Save this login information, as it is not possible to recover if it is lost or forgotten
33 ** In the event that the processor does not allow you to log in with the chosen credentials (i.e. it repeatedly prompts for credentials)
34 *** Attempt to log in with username "crestron" and no password
35 *** Once logged into Text Console, run the following commands, replacing the "username" and "password" with your desired credentials
36 **** ##adduser -N:username -P:password##
37 **** ##addusertogroup -N:username -G:Administrators##
Alexander Mott 32.1 38 * Run commands to enable connecting to the ShowRunnerHUB™ interface and prevent issues with license loading on processor reboot:
39 ** Disable CWS Anti-CSRF feature (case sensitive): ##cwsanticsrf OFF##
40 ** Force waiting to start program: ##startprogafterrouter on##
41 ** Processor must be rebooted with "##reboot##" command before these take effect, but you can wait to reboot if there are other settings you must change that also require a reboot
Alexander Mott 1.2 42 * Determine whether the lighting control hardware will be connected to the ZUM-HUB4's LAN port or the Control Subnet port:
Alexander Mott 31.1 43 ** If the system is standalone (not integrated with building LAN), then lighting hardware can be connected to either the LAN port or the Control Subnet port, but it is still recommended to use the Control Subnet for Crestron hardware as the ZUM-HUB4 has a router built-in that will assign IP addresses:
Alexander Mott 1.2 44 *** If connecting lighting hardware to the LAN port, then you must configure the LAN as a static IP (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a processor IP address of (% style="color:blue" %)**10.0.0.10**(%%)):
45 **** Disable DHCP: ##dhcp 0 off##
46 **** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.10**(%%)##
47 **** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)##
48 **** Set default gateway: ##defr 0 **10.0.0.1**##
49 **** Set hostname: ##host HUB4-CPP##
Alexander Mott 30.1 50 **** Optionally, set secure gateway: ##securegateway default ##
51 ***** Note: this setting enables unsecure connections to the processor from the LAN. This is necessary if ZUMNET-JBOXs or other non-secure Crestron devices (such as 3-Series EISC) will be connected via the LAN port of the processor
Alexander Mott 1.2 52 **** Reboot the processor: ##reboot##
Alexander Mott 31.1 53 *** If connecting lighting hardware to the Control Subnet port, then you may either use the default IP scheme of the processor, or you may optionally configure the Control Subnet. Do not connect an external router to the Control Subnet port, as doing so will cause the internal DHCP server to shut down. If manually configuring the control subnet, we recommend the following IP range as it won't conflict with corporate networks:
Alexander Mott 1.2 54 **** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox:
55 ***** Set routing to "Manual" with the start address and subnet size
Mark Kohlmann 4.1 56 ***** E.g., a setting of "100.64.0.0/20" will have the processor at 10.64.0.1 with an IP mask of 255.255.240.0 and a default gateway and DNS server at 100.64.0.2
57 **** Using Text Console commands (example for a **100.64.0.0(% style="color:darkgoldenrod" %)/20(%%)** subnet, with a processor IP address of (% style="color:blue" %)**100.64.0.1**(%%))
58 ***** Set CS IP: ##csrouterprefix **100.64.0.0/20**##
Alexander Mott 1.2 59 ***** Reboot the processor: ##reboot##
60 ** If the system is intended to connect to the building LAN:
61 *** The building LAN must be connected to ZUM-HUB4's LAN port
62 *** The ZUM-HUB4's LAN IP settings should be configured per the building requirements
63 *** Any connected lighting hardware must either:
64 ***1. Be on the building LAN
Mark Kohlmann 4.1 65 ***1*. The ZUM-HUB4 LAN should be configured with a static IP or DHCP reservation
66 ***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices
Alexander Mott 24.1 67 ***1*. Run the command: ##securegateway default##
Alexander Mott 1.3 68 ***1. Be connected to the Control Subnet port
69 ***1*. Control Subnet must be configured correctly (see above)
70 ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off##
Alexander Mott 34.1 71 * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]]
Alexander Mott 1.1 72
Alexander Mott 12.1 73 = Update NVRAM Folder Permissions =
Alexander Mott 1.1 74
Alexander Mott 2.1 75 * Ensure that the NVRAM folder permissions are set correctly using a third party SFTP program:
Alexander Mott 7.1 76 ** FileZilla instructions ([[video example>>attach:FileZilla HUB4 NVRAM Permissions Change.mp4]]):
Alexander Mott 2.1 77 *** Connect to the processor at port 22
78 *** Locate the "nvram" folder
79 *** Right click the folder and select "Change File Attributes"
80 *** Change "Numeric Value" to 777
Alexander Mott 23.1 81 *** Disconnect from the processor in FileZilla
Alexander Mott 2.1 82 ** WinSCP instructions:
83 *** Connect to the processor at port 22
84 *** Locate the "nvram" folder
85 *** Right click the folder and select "Properties"
86 *** Change "Octal Value" to 2777
Alexander Mott 23.1 87 *** Disconnect from the processor WinSCP
Alexander Mott 2.1 88
Alexander Mott 12.1 89 = Crestron License Generation =
Alexander Mott 2.1 90
Alexander Mott 1.1 91 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network
Alexander Mott 2.1 92 * Connect to the ZUM-HUB4 in Crestron Toolbox
Austin Weygandt 26.1 93 ** Run the "##ver##" and verify that the reported firmware is v2.8000.00009 or greater (**NOTE**: older firmware will report the license as "Canvas Control" rather than "ZumHubProgramming" and will not work)
Alexander Mott 23.1 94 ** Open the Functions>License Management... window
95 *** If "ZumHubProgramming" license is listed with "Expiration: Never", then the license has already been activated and this step is not necessary
96 ** Navigate to the Functions>License Management...>Add License tab
Alexander Mott 2.1 97 ** Open [[Crestron's SW-HUB4-PROG licensing form>>https://app.smartsheet.com/b/form/e06b27d442ba4e668e31ffdf5f6e6322]] in a web browser and generate the license key
98 *** The Customer Number and PO# must be provided by the Crestron Agent for the job
99 *** The Hostname and System Key can be viewed in Toolbox by navigating to Functions>License Management...>Add License
100 ** In Toolbox, paste the generated license key into the "License Key:" field of the Add License menu
101 ** Click the "Apply" button
Alexander Mott 5.1 102 * Continue [[SHOWRUNNER™ deployment>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] as normal
Alexander Mott 1.1 103
Alexander Mott 22.1 104 {{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HProgramLoad"/}}
Alexander Mott 14.1 105
Alexander Mott 22.1 106 {{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HLicenseandConfigurationDeployment"/}}
Alexander Mott 16.1 107
Alexander Mott 22.1 108 {{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HSetSystemTime"/}}
Alexander Mott 16.1 109
Alexander Mott 12.1 110 = Accessing the showrunnerHUB™ Web UI =
Alexander Mott 1.1 111
Alexander Mott 5.1 112 Due to Crestron's Zūm Program running in parallel with the SHOWRUNNER™ program, navigating to the processor's IP address in a web browser will no longer redirect you to the showrunnerHUB™ UI.
113
Austin Weygandt 11.1 114 Instead, you must add "/cws/showrunner/app/" after the IP address in order to access the Web UI (e.g. [[https:~~/~~/100.64.0.1/cws/showrunner/app/>>https://100.64.0.1/cws/showrunner/app]]) **DO NOT OMIT THE LAST "/"**
Craig Lewis 8.1 115
116 ZUM-HUB4 Currently does NOT support XPANEL:
117 The XPanel does not launch from the Showrunner HUB webpage. To access the XPanel, extract the VTZ file from the showrunner™ puf file and launch. Select Options>Host Settings and input the Host IP, IPID, Port 41794, check SSL, and Open. Type in the username and password and wait for the XPanel to connect.