Changes for page ZUM-HUB4 Processor Setup

Last modified by Alexander Mott on 2026/03/04 22:05

From version 56.1
edited by Alexander Mott
on 2026/03/04 22:05
Change comment: There is no comment for this version
To version 53.1
edited by Alexander Mott
on 2026/03/04 20:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,13 +3,12 @@
3 3  {{/info}}
4 4  
5 5  {{warning}}
6 -ZUM-HUB4 requires **firmware v2.8000.00009 or greater** for third party software to be loaded.
7 -Text console "**##ver##**" command will give the current firmware version.
6 +ZUM-HUB4 requires firmware version **2.8000.00009 or greater** for third party software to be loaded.
7 +Text console "**##ver##**" command gives current firmware version.
8 8  {{/warning}}
9 9  
10 10  {{error}}
11 -Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive.
12 -The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command)
11 +All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. **
13 13  {{/error}}
14 14  
15 15  {{error}}
... ... @@ -17,7 +17,9 @@
17 17  {{/error}}
18 18  
19 19  {{error}}
20 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. **
19 +Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive.
20 +
21 +The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command)
21 21  {{/error}}
22 22  
23 23  {{box cssClass="floatinginfobox" title="**CONTENTS**"}}
... ... @@ -85,9 +85,8 @@
85 85  ***1. Be connected to the Control Subnet port
86 86  ***1*. Control Subnet must be configured correctly (see above)
87 87  ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off##
89 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]]
88 88  
89 -{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HFirmwareUpdate"/}}
90 -
91 91  = Update NVRAM Folder Permissions =
92 92  
93 93  * Ensure that the NVRAM folder permissions are set correctly using a third party SFTP program: