Changes for page ZUM-HUB4 Processor Setup
Last modified by Alexander Mott on 2026/03/04 22:05
From version 54.1
edited by Alexander Mott
on 2026/03/04 20:17
on 2026/03/04 20:17
Change comment:
There is no comment for this version
To version 52.2
edited by Alexander Mott
on 2026/03/04 20:07
on 2026/03/04 20:07
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,15 +2,8 @@ 2 2 This page is for ZUM-HUB4 deployments. For other processors, see our [[normal processor setup page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome]]. 3 3 {{/info}} 4 4 5 -{{warning}} 6 -ZUM-HUB4 requires firmware version **2.8000.00009 or greater** for third party software to be loaded. 7 -Text console "**##ver##**" command gives current firmware version. 8 -{{/warning}} 9 - 10 10 {{error}} 11 -Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 12 - 13 -The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command) 6 +All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 14 14 {{/error}} 15 15 16 16 {{error}} ... ... @@ -18,9 +18,16 @@ 18 18 {{/error}} 19 19 20 20 {{error}} 21 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 14 +Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 15 + 16 +The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command) 22 22 {{/error}} 23 23 19 +{{warning}} 20 +ZUM-HUB4 requires firmware version **2.8000.00009 or greater** for third party software to be loaded. 21 +(Once installed, running the command should report a FW version of 2.8000.00009 or greater.) 22 +{{/warning}} 23 + 24 24 {{box cssClass="floatinginfobox" title="**CONTENTS**"}} 25 25 {{toc/}} 26 26 {{/box}} ... ... @@ -86,9 +86,8 @@ 86 86 ***1. Be connected to the Control Subnet port 87 87 ***1*. Control Subnet must be configured correctly (see above) 88 88 ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off## 89 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 89 89 90 -{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HFirmwareUpdate"/}} 91 - 92 92 = Update NVRAM Folder Permissions = 93 93 94 94 * Ensure that the NVRAM folder permissions are set correctly using a third party SFTP program: