Changes for page ZUM-HUB4 Processor Setup
Last modified by Alexander Mott on 2026/03/04 22:05
From version 53.1
edited by Alexander Mott
on 2026/03/04 20:09
on 2026/03/04 20:09
Change comment:
There is no comment for this version
To version 54.1
edited by Alexander Mott
on 2026/03/04 20:17
on 2026/03/04 20:17
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,9 @@ 8 8 {{/warning}} 9 9 10 10 {{error}} 11 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 11 +Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 12 + 13 +The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command) 12 12 {{/error}} 13 13 14 14 {{error}} ... ... @@ -16,9 +16,7 @@ 16 16 {{/error}} 17 17 18 18 {{error}} 19 -Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 20 - 21 -The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command) 21 +All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 22 22 {{/error}} 23 23 24 24 {{box cssClass="floatinginfobox" title="**CONTENTS**"}} ... ... @@ -86,8 +86,9 @@ 86 86 ***1. Be connected to the Control Subnet port 87 87 ***1*. Control Subnet must be configured correctly (see above) 88 88 ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off## 89 -* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 90 90 90 +{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HFirmwareUpdate"/}} 91 + 91 91 = Update NVRAM Folder Permissions = 92 92 93 93 * Ensure that the NVRAM folder permissions are set correctly using a third party SFTP program: