Changes for page ZUM-HUB4 Processor Setup
Last modified by Alexander Mott on 2026/03/04 22:05
From version 50.1
edited by Alexander Mott
on 2025/04/30 15:58
on 2025/04/30 15:58
Change comment:
There is no comment for this version
To version 53.1
edited by Alexander Mott
on 2026/03/04 20:09
on 2026/03/04 20:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,8 +2,13 @@ 2 2 This page is for ZUM-HUB4 deployments. For other processors, see our [[normal processor setup page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome]]. 3 3 {{/info}} 4 4 5 +{{warning}} 6 +ZUM-HUB4 requires firmware version **2.8000.00009 or greater** for third party software to be loaded. 7 +Text console "**##ver##**" command gives current firmware version. 8 +{{/warning}} 9 + 5 5 {{error}} 6 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to factory reset the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 11 +All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 7 7 {{/error}} 8 8 9 9 {{error}} ... ... @@ -11,14 +11,11 @@ 11 11 {{/error}} 12 12 13 13 {{error}} 14 -Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to firmware versions 3.009.0039 or newer require first updating to 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 19 +Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 20 + 21 +The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command) 15 15 {{/error}} 16 16 17 -{{warning}} 18 -ZUM-HUB4 requires firmware version 2.006.0034 or greater for third party software to be loaded. 19 -(Once installed, running the "##ver##" command should report a FW version of 2.8000.00009 or greater.) 20 -{{/warning}} 21 - 22 22 {{box cssClass="floatinginfobox" title="**CONTENTS**"}} 23 23 {{toc/}} 24 24 {{/box}}