Changes for page ZUM-HUB4 Processor Setup

Last modified by Alexander Mott on 2026/03/04 22:05

From version 50.1
edited by Alexander Mott
on 2025/04/30 15:58
Change comment: There is no comment for this version
To version 52.2
edited by Alexander Mott
on 2026/03/04 20:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,7 @@
3 3  {{/info}}
4 4  
5 5  {{error}}
6 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to factory reset the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. **
6 +All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to [[factory reset>>https://docs.crestron.com/en-us/8559/Content/Topics/Reference/Restore-Factory-Defaults.htm]] the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. **
7 7  {{/error}}
8 8  
9 9  {{error}}
... ... @@ -11,12 +11,14 @@
11 11  {{/error}}
12 12  
13 13  {{error}}
14 -Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to firmware versions 3.009.0039 or newer require first updating to 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive.
14 +Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive.
15 +
16 +The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command)
15 15  {{/error}}
16 16  
17 17  {{warning}}
18 -ZUM-HUB4 requires firmware version 2.006.0034 or greater for third party software to be loaded.
19 -(Once installed, running the "##ver##" command should report a FW version of 2.8000.00009 or greater.)
20 +ZUM-HUB4 requires firmware version **2.8000.00009 or greater** for third party software to be loaded.
21 +(Once installed, running the command should report a FW version of 2.8000.00009 or greater.)
20 20  {{/warning}}
21 21  
22 22  {{box cssClass="floatinginfobox" title="**CONTENTS**"}}