Changes for page ZUM-HUB4 Processor Setup
Last modified by Alexander Mott on 2025/06/23 20:03
From version 50.1
edited by Alexander Mott
on 2025/04/30 15:58
on 2025/04/30 15:58
Change comment:
There is no comment for this version
To version 51.1
edited by Alexander Mott
on 2025/06/23 20:03
on 2025/06/23 20:03
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,7 +11,9 @@ 11 11 {{/error}} 12 12 13 13 {{error}} 14 -Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to firmware versions 3.009.0039 or newer require first updating to 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 14 +Per Crestron's ZUM-HUB4 firmware v3.009.0039 release notes, updating to PUF versions 3.009.0039 or newer require first updating to PUF version 3.008.054. Failure to do so will result in longer ##progreset## times (up to 10 minutes) as well as other potential issues such as keypads becoming unresponsive. 15 + 16 +The PUF firmware version is can be viewed using the ##**ver -all**## command (PUF firmware version is different than the version displayed with just the ##**ver**## command) 15 15 {{/error}} 16 16 17 17 {{warning}}