Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -39,7 +39,7 @@ 39 39 ** Disable CWS Anti-CSRF feature (case sensitive): ##cwsanticsrf OFF## 40 40 ** Force waiting to start program: ##startprogafterrouter on## 41 41 ** Processor must be rebooted with "##reboot##" command before these take effect, but you can wait to reboot if there are other settings you must change that also require a reboot 42 -** ShowRunnerCLC™ .puf versions 3.042 and newer automatically run this command when the "Configure ZUM-HUB4" and "Reboot ZUM-HUB4" optionsareselected.42 +** ShowRunnerCLC™ .puf versions 3.042 and newer automatically run this command when the "Configure ZUM-HUB4" option is selected. 43 43 * Determine whether the lighting control hardware will be connected to the ZUM-HUB4's LAN port or the Control Subnet port: 44 44 ** If the system is standalone (not integrated with building LAN), then lighting hardware can be connected to either the LAN port or the Control Subnet port, but it is still recommended to use the Control Subnet for Crestron hardware as the ZUM-HUB4 has a router built-in that will assign IP addresses: 45 45 *** If connecting lighting hardware to the LAN port, then you must configure the LAN as a static IP (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a processor IP address of (% style="color:blue" %)**10.0.0.10**(%%)): ... ... @@ -58,7 +58,7 @@ 58 58 **** Using Text Console commands (example for a **100.64.0.0(% style="color:darkgoldenrod" %)/20(%%)** subnet, with a processor IP address of (% style="color:blue" %)**100.64.0.1**(%%)) 59 59 ***** Set CS IP: ##csrouterprefix **100.64.0.0/20**## 60 60 ***** Reboot the processor: ##reboot## 61 -**** ShowRunnerCLC™ .puf versions 3.042 and newer automatically run this command when the "Configure ZUM-HUB4 Control Subnet" and "Reboot ZUM-HUB4" optionsareselected.61 +**** ShowRunnerCLC™ .puf versions 3.042 and newer automatically run this command when the "Configure ZUM-HUB4 Control Subnet" option is selected. 62 62 ** If the system is intended to connect to the building LAN: 63 63 *** The building LAN must be connected to ZUM-HUB4's LAN port 64 64 *** The ZUM-HUB4's LAN IP settings should be configured per the building requirements