Changes for page ZUM-HUB4 Processor Setup
Last modified by Craig Lewis on 2025/03/13 15:50
From version 3.1
edited by Alexander Mott
on 2022/06/30 17:04
on 2022/06/30 17:04
Change comment:
There is no comment for this version
To version 4.1
edited by Mark Kohlmann
on 2022/06/30 17:13
on 2022/06/30 17:13
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -32,14 +32,14 @@ 32 32 **** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 33 33 **** Set default gateway: ##defr 0 **10.0.0.1**## 34 34 **** Set hostname: ##host HUB4-CPP## 35 -**** Set secure gateway: ##securegateway default##35 +**** If ZUMNET-JBOXs will be connected via the LAN port set secure gateway: ##securegateway default ##(Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices) 36 36 **** Reboot the processor: ##reboot## 37 -*** If connecting lighting hardware to the Control Subnet port, then you m ustconfigure the Control Subnet:37 +*** If connecting lighting hardware to the Control Subnet port, then you may configure the Control Subnet. This is a recommended range as it won't conflict with corporate networks: 38 38 **** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox: 39 39 ***** Set routing to "Manual" with the start address and subnet size 40 -***** E.g., a setting of "10 .0.0.0/24" will have the processor at 10.0.0.1 with an IP mask of 255.255.255.0 and a default gateway and DNS server at 10.0.0.241 -**** Using Text Console commands (example for a **10 .0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a processor IP address of (% style="color:blue" %)**10.0.0.1**(%%))42 -***** Set CS IP: ##csrouterprefix **10 .0.0.0/24**##40 +***** E.g., a setting of "100.64.0.0/20" will have the processor at 10.64.0.1 with an IP mask of 255.255.240.0 and a default gateway and DNS server at 100.64.0.2 41 +**** Using Text Console commands (example for a **100.64.0.0(% style="color:darkgoldenrod" %)/20(%%)** subnet, with a processor IP address of (% style="color:blue" %)**100.64.0.1**(%%)) 42 +***** Set CS IP: ##csrouterprefix **100.64.0.0/20**## 43 43 ***** Reboot the processor: ##reboot## 44 44 ** If the system is intended to connect to the building LAN: 45 45 *** The building LAN must be connected to ZUM-HUB4's LAN port ... ... @@ -46,8 +46,9 @@ 46 46 *** The ZUM-HUB4's LAN IP settings should be configured per the building requirements 47 47 *** Any connected lighting hardware must either: 48 48 ***1. Be on the building LAN 49 -***1*. The ZUM-HUB4 LAN should be configured with a static IP 50 -***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices 49 +***1*. The ZUM-HUB4 LAN should be configured with a static IP or DHCP reservation 50 +***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices 51 +***1*. This requires: ##securegateway default## 51 51 ***1. Be connected to the Control Subnet port 52 52 ***1*. Control Subnet must be configured correctly (see above) 53 53 ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off##