Changes for page ZUM-HUB4 Processor Setup
Last modified by Alexander Mott on 2025/04/30 15:58
From version 28.1
edited by Alexander Mott
on 2023/05/16 14:24
on 2023/05/16 14:24
Change comment:
There is no comment for this version
To version 23.1
edited by Alexander Mott
on 2022/09/19 19:28
on 2022/09/19 19:28
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,8 +5,8 @@ 5 5 6 6 (% class="box warningmessage" %) 7 7 ((( 8 -ZUM-HUB4 requires firmware version 2.00 6.0034or greater for third party software to be loaded.9 -(Once installed, running the "##ver##" command should report a FW version of 2. 8000.00009or greater.)8 +ZUM-HUB4 requires firmware version 2.005.0056 or greater for third party software to be loaded. 9 +(Once installed, running the "##ver##" command should report a FW version of 2.7100.00016 or greater.) 10 10 ))) 11 11 12 12 {{box cssClass="floatinginfobox" title="**CONTENTS**"}} ... ... @@ -13,6 +13,8 @@ 13 13 {{toc/}} 14 14 {{/box}} 15 15 16 +(% class="row" %) 17 +((( 16 16 **Licensing tutorial:** 17 17 18 18 //Note: Please use Chrome or Firefox to download the License from [[https:~~/~~/portal.chiefintegrations.com>>https://portal.chiefintegrations.com]]. Edge and Internet Explorer do not work properly.// ... ... @@ -36,8 +36,8 @@ 36 36 **** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 37 37 **** Set default gateway: ##defr 0 **10.0.0.1**## 38 38 **** Set hostname: ##host HUB4-CPP## 39 -**** If ZUMNET-JBOXs or other non-secure Crestron devices such as 3-Series EISCwill be connected via the LAN port, set secure gateway: ##securegateway default ##40 -***** Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices 41 +**** If ZUMNET-JBOXs will be connected via the LAN port, set secure gateway: ##securegateway default ## 42 +***** (Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices) 41 41 **** Reboot the processor: ##reboot## 42 42 *** If connecting lighting hardware to the Control Subnet port, then you may optionally configure the Control Subnet. If manually configuring the control subnet, we recommend the following IP range as it won't conflict with corporate networks: 43 43 **** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox: ... ... @@ -53,7 +53,7 @@ 53 53 ***1. Be on the building LAN 54 54 ***1*. The ZUM-HUB4 LAN should be configured with a static IP or DHCP reservation 55 55 ***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices 56 -***1*. Run thecommand: ##securegateway default##58 +***1*. This requires: ##securegateway default## 57 57 ***1. Be connected to the Control Subnet port 58 58 ***1*. Control Subnet must be configured correctly (see above) 59 59 ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off## ... ... @@ -82,7 +82,7 @@ 82 82 83 83 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network 84 84 * Connect to the ZUM-HUB4 in Crestron Toolbox 85 -** Run the "##ver##" and verify that the reported firmware is v2. 8000.00009or greater(**NOTE**: older firmware will report the license as "Canvas Control" rather than "ZumHubProgramming" and will not work)87 +** Run the "##ver##" and verify that the reported firmware is v2.7100.00016 or greater 86 86 ** Open the Functions>License Management... window 87 87 *** If "ZumHubProgramming" license is listed with "Expiration: Never", then the license has already been activated and this step is not necessary 88 88 ** Navigate to the Functions>License Management...>Add License tab ... ... @@ -107,3 +107,4 @@ 107 107 108 108 ZUM-HUB4 Currently does NOT support XPANEL: 109 109 The XPanel does not launch from the Showrunner HUB webpage. To access the XPanel, extract the VTZ file from the showrunner™ puf file and launch. Select Options>Host Settings and input the Host IP, IPID, Port 41794, check SSL, and Open. Type in the username and password and wait for the XPanel to connect. 112 +)))