Changes for page ZUM-HUB4 Processor Setup

Last modified by Craig Lewis on 2025/03/13 15:50

From version 23.1
edited by Alexander Mott
on 2022/09/19 19:28
Change comment: There is no comment for this version
To version 25.1
edited by Alexander Mott
on 2023/05/11 15:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -38,8 +38,8 @@
38 38  **** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)##
39 39  **** Set default gateway: ##defr 0 **10.0.0.1**##
40 40  **** Set hostname: ##host HUB4-CPP##
41 -**** If ZUMNET-JBOXs will be connected via the LAN port, set secure gateway: ##securegateway default ##
42 -***** (Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices)
41 +**** If ZUMNET-JBOXs or other non-secure Crestron devices such as 3-Series EISC will be connected via the LAN port, set secure gateway: ##securegateway default ##
42 +***** Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices
43 43  **** Reboot the processor: ##reboot##
44 44  *** If connecting lighting hardware to the Control Subnet port, then you may optionally configure the Control Subnet. If manually configuring the control subnet, we recommend the following IP range as it won't conflict with corporate networks:
45 45  **** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox:
... ... @@ -55,7 +55,7 @@
55 55  ***1. Be on the building LAN
56 56  ***1*. The ZUM-HUB4 LAN should be configured with a static IP or DHCP reservation
57 57  ***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices
58 -***1*. This requires: ##securegateway default##
58 +***1*. Run the command: ##securegateway default##
59 59  ***1. Be connected to the Control Subnet port
60 60  ***1*. Control Subnet must be configured correctly (see above)
61 61  ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off##