Changes for page ZUM-HUB4 Processor Setup
Last modified by Craig Lewis on 2025/03/13 15:50
From version 18.1
edited by Alexander Mott
on 2022/09/17 00:25
on 2022/09/17 00:25
Change comment:
There is no comment for this version
To version 29.1
edited by Alexander Mott
on 2023/05/19 17:22
on 2023/05/19 17:22
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,11 +5,11 @@ 5 5 6 6 (% class="box warningmessage" %) 7 7 ((( 8 -ZUM-HUB4 requires firmware version 2.00 5.0056or greater for third party software to be loaded.9 -(Once installed, running the "##ver##" command should report a FW version of 2. 7100.00016or greater.)8 +ZUM-HUB4 requires firmware version 2.006.0034 or greater for third party software to be loaded. 9 +(Once installed, running the "##ver##" command should report a FW version of 2.8000.00009 or greater.) 10 10 ))) 11 11 12 -{{box title="**CONTENTS**"}} 12 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 13 13 {{toc/}} 14 14 {{/box}} 15 15 ... ... @@ -19,6 +19,8 @@ 19 19 20 20 [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]] 21 21 22 +{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HErrorBroadcasting"/}} 23 + 22 22 = IP Configuration and Console Commands = 23 23 24 24 * Connect to the ZUM-HUB4 via USB and create an admin-level CWS user ... ... @@ -36,8 +36,8 @@ 36 36 **** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 37 37 **** Set default gateway: ##defr 0 **10.0.0.1**## 38 38 **** Set hostname: ##host HUB4-CPP## 39 -**** If ZUMNET-JBOXs will be connected via the LAN port, set secure gateway: ##securegateway default ## 40 -***** (Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices)41 +**** If ZUMNET-JBOXs or other non-secure Crestron devices such as 3-Series EISC will be connected via the LAN port, set secure gateway: ##securegateway default ## 42 +***** Note: this setting defines whether or not a secure connection is required on the LAN side of the control processor for Crestron devices 41 41 **** Reboot the processor: ##reboot## 42 42 *** If connecting lighting hardware to the Control Subnet port, then you may optionally configure the Control Subnet. If manually configuring the control subnet, we recommend the following IP range as it won't conflict with corporate networks: 43 43 **** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox: ... ... @@ -53,7 +53,7 @@ 53 53 ***1. Be on the building LAN 54 54 ***1*. The ZUM-HUB4 LAN should be configured with a static IP or DHCP reservation 55 55 ***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices 56 -***1*. Thisrequires: ##securegateway default##58 +***1*. Run the command: ##securegateway default## 57 57 ***1. Be connected to the Control Subnet port 58 58 ***1*. Control Subnet must be configured correctly (see above) 59 59 ***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off## ... ... @@ -70,20 +70,22 @@ 70 70 *** Locate the "nvram" folder 71 71 *** Right click the folder and select "Change File Attributes" 72 72 *** Change "Numeric Value" to 777 73 -*** Disconnect from the processor 75 +*** Disconnect from the processor in FileZilla 74 74 ** WinSCP instructions: 75 75 *** Connect to the processor at port 22 76 76 *** Locate the "nvram" folder 77 77 *** Right click the folder and select "Properties" 78 78 *** Change "Octal Value" to 2777 79 -*** Disconnect from the processor 81 +*** Disconnect from the processor WinSCP 80 80 81 81 = Crestron License Generation = 82 82 83 83 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network 84 84 * Connect to the ZUM-HUB4 in Crestron Toolbox 85 -** Run the "##ver##" and verify that the reported firmware is v2.7100.00016 or greater 86 -** Navigate to Functions>License Management...>Add License 87 +** Run the "##ver##" and verify that the reported firmware is v2.8000.00009 or greater (**NOTE**: older firmware will report the license as "Canvas Control" rather than "ZumHubProgramming" and will not work) 88 +** Open the Functions>License Management... window 89 +*** If "ZumHubProgramming" license is listed with "Expiration: Never", then the license has already been activated and this step is not necessary 90 +** Navigate to the Functions>License Management...>Add License tab 87 87 ** Open [[Crestron's SW-HUB4-PROG licensing form>>https://app.smartsheet.com/b/form/e06b27d442ba4e668e31ffdf5f6e6322]] in a web browser and generate the license key 88 88 *** The Customer Number and PO# must be provided by the Crestron Agent for the job 89 89 *** The Hostname and System Key can be viewed in Toolbox by navigating to Functions>License Management...>Add License ... ... @@ -91,18 +91,12 @@ 91 91 ** Click the "Apply" button 92 92 * Continue [[SHOWRUNNER™ deployment>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] as normal 93 93 94 -= Program =98 +{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HProgramLoad"/}} 95 95 96 -{{display excludeFirstHeading=" true" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HProgramLoad"/}}100 +{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HLicenseandConfigurationDeployment"/}} 97 97 98 - = LicenseandConfigurationDeployment =102 +{{display excludeFirstHeading="false" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HSetSystemTime"/}} 99 99 100 -{{display excludeFirstHeading="true" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HLicenseandConfigurationDeployment"/}} 101 - 102 -= Set System Time = 103 - 104 -{{display excludeFirstHeading="true" reference="SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome" section="HSetSystemTime"/}} 105 - 106 106 = Accessing the showrunnerHUB™ Web UI = 107 107 108 108 Due to Crestron's Zūm Program running in parallel with the SHOWRUNNER™ program, navigating to the processor's IP address in a web browser will no longer redirect you to the showrunnerHUB™ UI.