... ... @@ -52,10 +52,12 @@
52 52  ***1. Be on the building LAN
53 53  ***1*. The ZUM-HUB4 LAN should be configured with a static IP
54 54  ***1*. Building network must be configured to allow communication between ZUM-HUB4 and all lighting devices
55 -***1. Be connected to the ZUM-HUB4's Control Subnet port, and the Control Subnet must be configured correctly (see above)
55 +***1. Be connected to the Control Subnet port
56 +***1*. Control Subnet must be configured correctly (see above)
57 +***1*. If lighting devices must be able to communicate with the building LAN, run the command: ##isolatenetworks off##
56 56  * Once IP settings are configured, there are additional commands that must be run:
57 57  ** Force waiting to start program: ##startprografterrouter on##
58 -** Disable CWS Anticsrf feature: ##cwsanticsrf off##
60 +** Disable CWS Anticsrf feature (case sensitive): ##cwsanticsrf OFF##
59 59  ** Reboot the processor: ##reboot##
60 60  
61 61  === Crestron License and Program Load ===