Changes for page DIN-CENCN-2 Setup
Last modified by Alexander Mott on 2024/02/09 01:01
From version 9.1
edited by Alexander Mott
on 2022/09/17 00:38
on 2022/09/17 00:38
Change comment:
There is no comment for this version
To version 14.1
edited by Alexander Mott
on 2023/07/10 14:54
on 2023/07/10 14:54
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,7 @@ 1 -{{box title="**CONTENTS**"}} 1 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 2 {{toc/}} 3 3 {{/box}} 4 4 5 -(% class="row" %) 6 -((( 7 -= DIN-CENCN-2s in SHOWRUNNER™ = 8 - 9 9 DIN-CENCN-2s are Cresnet-to-Ethernet bridges which convert data over the Cresnet bus into high-speed Ethernet traffic. This helps avoid issues with bandwidth over the Cresnet bus for jobs which have a large number of Cresnet devices, as well as allowing for additional power supplies to provide power Cresnet devices. 10 10 11 11 For SHOWRUNNER™ installations, the IP address of the DIN-CENCN-2 does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, DIN-CENCN-2s are identified to the processor via their IP-ID. Note that which Cresnet devices are landed at each Net of each DIN-CENCN-2 matters, and if devices are moved between Nets or between DIN-CENCN-2s then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the DIN-CENCN-2 IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Dx##" range. ... ... @@ -12,7 +12,7 @@ 12 12 13 13 = IP Configuration = 14 14 15 -Typically, each DIN-CENCN-2 will need to be initially configured via USB, unless their MAC addresses are already known and the lighting network has a DHCP server (either by running DHCP server software on your computer, or if the processor has a control subnet or is running the [[S HOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™UserGuide& Wiki.Troubleshooting.DHCP Server.WebHome]]).11 +Typically, each DIN-CENCN-2 will need to be initially configured via USB, unless their MAC addresses are already known and the lighting network has a DHCP server (either by running DHCP server software on your computer, or if the processor has a control subnet or is running the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]). 16 16 17 17 Whether connected to the DIN-CENCN-2 via USB or Ethernet, the process to configure the static IP addresses is the same: 18 18 ... ... @@ -27,6 +27,14 @@ 27 27 ** Reboot the DIN-CENCN-2: ##reboot## 28 28 * Repeat for all DIN-CENCN-2s on the job 29 29 26 +(% class="wikigeneratedid" %) 27 += Useful Commands = 28 + 29 +Below is a list of useful commands that can be used with DIN-CENCN-2 to help with troubleshooting Cresnet issues. 30 + 31 +* ##ppndiscover## - this command scans each of the DIN-CENCN-2's Nets and prints out a list of connected Cresnet devices identified by their connection ID and their TSID 32 +* ##cnettest## - this command scans each Net and prints a summary of the number of devices on each net as well as any Cresnet issues found (e.g., "Y short to Z" or "Power Fault") 33 + 30 30 = Moving Cresnet Devices = 31 31 32 32 In SHOWRUNNER™, which Net each Cresnet cable is landed on is important. Each DIN-CENCN-2 is firmware limited to a maximum of 25 Cresnet devices per Net, and which CENCN-2/Net each device is on is tracked in the configuration file. If devices are moved between DIN-CENCN-2s or moved between Nets on the same DIN-CENCN-2, then the configuration file must be updated. Every device in the configuration has a ##"DeviceHostId"## (the host DIN-CENCN-2's IP-ID) and a ##"DeviceHostBranch"## (the Net of the DIN-CENCN-2) associated with it. ... ... @@ -37,4 +37,3 @@ 37 37 1. Cresnet IDs must be in the hexadecimal range 03 to 1B 38 38 1. Any children devices (such as NS occ sensors, photocells, GLPPA-KP keypads, etc.) must also be moved. If the parent Cresnet ID is changed then the children IDs must also be updated 39 39 1. If devices are moved from a DIN-CENCN-2 to be landed directly on a processor (or landed on a DIN-HUB on a processor), then the device host ID should be ##null## and the host branch should be ##0## 40 -)))