Changes for page DIN-CENCN-2 Setup
Last modified by Alexander Mott on 2024/02/09 01:01
From version 8.1
edited by Alexander Mott
on 2022/09/17 00:25
on 2022/09/17 00:25
Change comment:
There is no comment for this version
To version 13.1
edited by Alexander Mott
on 2023/05/16 18:08
on 2023/05/16 18:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,7 @@ 1 -{{box title="**CONTENTS**"}} 1 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 2 {{toc/}} 3 3 {{/box}} 4 4 5 -= DIN-CENCN-2s in SHOWRUNNER™ = 6 - 7 7 DIN-CENCN-2s are Cresnet-to-Ethernet bridges which convert data over the Cresnet bus into high-speed Ethernet traffic. This helps avoid issues with bandwidth over the Cresnet bus for jobs which have a large number of Cresnet devices, as well as allowing for additional power supplies to provide power Cresnet devices. 8 8 9 9 For SHOWRUNNER™ installations, the IP address of the DIN-CENCN-2 does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, DIN-CENCN-2s are identified to the processor via their IP-ID. Note that which Cresnet devices are landed at each Net of each DIN-CENCN-2 matters, and if devices are moved between Nets or between DIN-CENCN-2s then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the DIN-CENCN-2 IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Dx##" range. ... ... @@ -10,7 +10,7 @@ 10 10 11 11 = IP Configuration = 12 12 13 -Typically, each DIN-CENCN-2 will need to be initially configured via USB, unless their MAC addresses are already known and the lighting network has a DHCP server (either by running DHCP server software on your computer, or if the processor has a control subnet or is running the [[S HOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™UserGuide& Wiki.Troubleshooting.DHCP Server.WebHome]]).11 +Typically, each DIN-CENCN-2 will need to be initially configured via USB, unless their MAC addresses are already known and the lighting network has a DHCP server (either by running DHCP server software on your computer, or if the processor has a control subnet or is running the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]). 14 14 15 15 Whether connected to the DIN-CENCN-2 via USB or Ethernet, the process to configure the static IP addresses is the same: 16 16