Changes for page DIN-CENCN-2 Setup
Last modified by Alexander Mott on 2024/02/09 01:01
From version 6.1
edited by Alexander Mott
on 2022/09/16 20:54
on 2022/09/16 20:54
Change comment:
There is no comment for this version
To version 18.1
edited by Alexander Mott
on 2024/02/09 01:01
on 2024/02/09 01:01
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,32 +1,50 @@ 1 -{{box title="**C ontents**"}}1 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 2 {{toc/}} 3 3 {{/box}} 4 4 5 -(% class="row" %) 6 -((( 7 -= DIN-CENCN-2s in SHOWRUNNER™ = 5 +DIN-CENCN-2s are Cresnet-to-Ethernet bridges which convert data over the Cresnet bus into high-speed Ethernet traffic. This helps avoid issues with bandwidth over the Cresnet bus for jobs which have a large number of Cresnet devices, as well as allowing for additional power supplies to provide power Cresnet devices. They are analogous to [[CEN-GWEXERs>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.CEN-GWEXER Setup.WebHome]] for Crestron wireless systems. 8 8 9 -DIN-CENCN-2s are Cresnet-to-Ethernet bridges which convert data over the Cresnet bus into high-speed Ethernet traffic. This helps avoid issues with bandwidth over the Cresnet bus for jobs which have a large number of Cresnet devices, as well as allowing for additional power supplies to provide power Cresnet devices. 10 - 11 11 For SHOWRUNNER™ installations, the IP address of the DIN-CENCN-2 does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, DIN-CENCN-2s are identified to the processor via their IP-ID. Note that which Cresnet devices are landed at each Net of each DIN-CENCN-2 matters, and if devices are moved between Nets or between DIN-CENCN-2s then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the DIN-CENCN-2 IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Dx##" range. 12 12 13 13 = IP Configuration = 14 14 15 -Typically, each DIN-CENCN-2 will need to be initially configured via USB ,unless their MAC addresses are already known and the lighting network has a DHCP server(eitherbyrunningDHCP server software on your computer,oriftheprocessorhas a control subnetoris runningHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ UserGuide& Wiki.Troubleshooting.DHCP.WebHome]]).11 +Typically, each DIN-CENCN-2 will need to be initially configured via USB (USB Type B) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>url:https://wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20Setup%20Guide/Troubleshooting%20Guide/Advanced%20Tools/DHCP%20Server/]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. 16 16 17 - Whether connectedto theDIN-CENCN-2via USBor Ethernet, the process to configure the staticIP addresses is the same:13 +== DHCP Configuration == 18 18 15 +If the lighting network has a permanent DHCP server, then DIN-CENCN-2s only require their IP table to be configured, though it is good practice to also record or update their hostname. If the MAC addresses for the DIN-CENCN-2s are not known, then the best way to update their configuration is via USB (USB Type B). If you are able to identify the DIN-CENCN-2s by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected to the DIN-CENCN-2 via USB or Ethernet, the process to configure the IP table and hostname is the same: 16 + 19 19 * Open Text Console in Toolbox and connect to the DIN-CENCN-2 18 +* Run the following commands to configure the DIN-CENCN-2's IP table and hostname (example is for a CENCN-2 IP-ID of (% style="color:olive" %)**D1**(%%), a processor IP address of (% style="color:orange" %)**172.22.0.1**(%%), and a hostname of (% style="color:purple" %)**CENCN-L1**(%%)) 19 +** Update IP table: ##addm (% style="color:olive" %)**D1**(%%) (% style="color:orange" %)**172.22.0.1**(%%)## 20 +** Set hostname: ##host (% style="color:purple" %)**CENCN-L1**(%%)## 21 +** Reboot the DIN-CENCN-2: ##reboot## 22 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 23 +* Repeat for all DIN-CENCN-2s on the job 24 + 25 +== Static Configuration == 26 + 27 +If there is no permanent DHCP server on the lighting network, then DIN-CENCN-2s should be configured with static IP addresses via USB (Type B). If a temporary DHCP server is connected to the lighting network and you are able to identify DIN-CENCN-2s by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected to the DIN-CENCN-2 via USB or Ethernet, the process to configure the static IP addresses is the same: 28 + 29 +* Open Text Console in Toolbox and connect to the DIN-CENCN-2 20 20 * Run the following commands to configure the DIN-CENCN-2's IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a CENCN-2 IP address of (% style="color:blue" %)**10.0.0.12**(%%), a CENCN-2 IP-ID of (% style="color:olive" %)**D1**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:purple" %)**CENCN-L1**(%%)) 21 -** Disable DHCP: ##dhcp off## 22 22 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.12**(%%)## 23 23 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 24 24 ** Set default gateway: ##defr 0 **10.0.0.1**## 34 +** Disable DHCP: ##dhcp off## 25 25 ** Update IP table: ##addm (% style="color:olive" %)**D1**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 26 26 ** Set hostname: ##host (% style="color:purple" %)**CENCN-L1**(%%)## 27 27 ** Reboot the DIN-CENCN-2: ##reboot## 38 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 28 28 * Repeat for all DIN-CENCN-2s on the job 29 29 41 += Useful Commands = 42 + 43 +Below is a list of useful commands that can be used with DIN-CENCN-2 to help with troubleshooting Cresnet issues. 44 + 45 +* ##ppndiscover## - this command scans each of the DIN-CENCN-2's Nets and prints out a list of connected Cresnet devices identified by their connection ID and their TSID 46 +* ##cnettest## - this command scans each Net and prints a summary of the number of devices on each net as well as any Cresnet issues found (e.g., "Y short to Z" or "Power Fault") 47 + 30 30 = Moving Cresnet Devices = 31 31 32 32 In SHOWRUNNER™, which Net each Cresnet cable is landed on is important. Each DIN-CENCN-2 is firmware limited to a maximum of 25 Cresnet devices per Net, and which CENCN-2/Net each device is on is tracked in the configuration file. If devices are moved between DIN-CENCN-2s or moved between Nets on the same DIN-CENCN-2, then the configuration file must be updated. Every device in the configuration has a ##"DeviceHostId"## (the host DIN-CENCN-2's IP-ID) and a ##"DeviceHostBranch"## (the Net of the DIN-CENCN-2) associated with it.