Changes for page DIN-CENCN-2 Setup
Last modified by Alexander Mott on 2024/02/09 01:01
From version 5.4
edited by Alexander Mott
on 2022/06/17 19:42
on 2022/06/17 19:42
Change comment:
Update document after refactoring.
To version 6.1
edited by Alexander Mott
on 2022/09/16 20:54
on 2022/09/16 20:54
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +1,16 @@ 1 -=== DIN-CENCN-2s in SHOWRUNNER™ === 1 +{{box title="**Contents**"}} 2 +{{toc/}} 3 +{{/box}} 2 2 5 +(% class="row" %) 6 +((( 7 += DIN-CENCN-2s in SHOWRUNNER™ = 8 + 3 3 DIN-CENCN-2s are Cresnet-to-Ethernet bridges which convert data over the Cresnet bus into high-speed Ethernet traffic. This helps avoid issues with bandwidth over the Cresnet bus for jobs which have a large number of Cresnet devices, as well as allowing for additional power supplies to provide power Cresnet devices. 4 4 5 5 For SHOWRUNNER™ installations, the IP address of the DIN-CENCN-2 does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, DIN-CENCN-2s are identified to the processor via their IP-ID. Note that which Cresnet devices are landed at each Net of each DIN-CENCN-2 matters, and if devices are moved between Nets or between DIN-CENCN-2s then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the DIN-CENCN-2 IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Dx##" range. 6 6 7 -= ==IP Configuration ===13 += IP Configuration = 8 8 9 9 Typically, each DIN-CENCN-2 will need to be initially configured via USB, unless their MAC addresses are already known and the lighting network has a DHCP server (either by running DHCP server software on your computer, or if the processor has a control subnet or is running the [[SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]]). 10 10 ... ... @@ -21,7 +21,7 @@ 21 21 ** Reboot the DIN-CENCN-2: ##reboot## 22 22 * Repeat for all DIN-CENCN-2s on the job 23 23 24 -= ==Moving Cresnet Devices ===30 += Moving Cresnet Devices = 25 25 26 26 In SHOWRUNNER™, which Net each Cresnet cable is landed on is important. Each DIN-CENCN-2 is firmware limited to a maximum of 25 Cresnet devices per Net, and which CENCN-2/Net each device is on is tracked in the configuration file. If devices are moved between DIN-CENCN-2s or moved between Nets on the same DIN-CENCN-2, then the configuration file must be updated. Every device in the configuration has a ##"DeviceHostId"## (the host DIN-CENCN-2's IP-ID) and a ##"DeviceHostBranch"## (the Net of the DIN-CENCN-2) associated with it. 27 27