Changes for page DIN-CENCN-2 Setup

Last modified by Alexander Mott on 2024/02/09 01:01

From version 14.1
edited by Alexander Mott
on 2023/07/10 14:54
Change comment: There is no comment for this version
To version 13.1
edited by Alexander Mott
on 2023/05/16 18:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -23,14 +23,6 @@
23 23  ** Reboot the DIN-CENCN-2: ##reboot##
24 24  * Repeat for all DIN-CENCN-2s on the job
25 25  
26 -(% class="wikigeneratedid" %)
27 -= Useful Commands =
28 -
29 -Below is a list of useful commands that can be used with DIN-CENCN-2 to help with troubleshooting Cresnet issues.
30 -
31 -* ##ppndiscover## - this command scans each of the DIN-CENCN-2's Nets and prints out a list of connected Cresnet devices identified by their connection ID and their TSID
32 -* ##cnettest## - this command scans each Net and prints a summary of the number of devices on each net as well as any Cresnet issues found (e.g., "Y short to Z" or "Power Fault")
33 -
34 34  = Moving Cresnet Devices =
35 35  
36 36  In SHOWRUNNER™, which Net each Cresnet cable is landed on is important. Each DIN-CENCN-2 is firmware limited to a maximum of 25 Cresnet devices per Net, and which CENCN-2/Net each device is on is tracked in the configuration file. If devices are moved between DIN-CENCN-2s or moved between Nets on the same DIN-CENCN-2, then the configuration file must be updated. Every device in the configuration has a ##"DeviceHostId"## (the host DIN-CENCN-2's IP-ID) and a ##"DeviceHostBranch"## (the Net of the DIN-CENCN-2) associated with it.