Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 9.1
edited by Alexander Mott
on 2022/10/05 16:17
Change comment: There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -18,14 +18,11 @@
18 18  
19 19  == Notes and Limitations ==
20 20  
21 -(% class="box errormessage" %)
22 -(((
23 23  * SHOWRUNNER™ version 3.014 or newer required
24 24  * Zūm Wired firmware version 1.02.10 or greater required
25 25  * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
26 26  * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
27 27  * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
28 -)))
29 29  
30 30  == Steps ==
31 31  
... ... @@ -64,12 +64,9 @@
64 64  = Zūm Wireless Discovery =
65 65  
66 66  == Notes and Limitations ==
67 -)))
68 68  
69 -(% class="box errormessage" %)
70 -(((
71 71  * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
72 -** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##**
66 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh##
73 73  * ZUM-NETBRIDGES must already be acquired to their respective gateway
74 74  * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
75 75  * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
... ... @@ -91,14 +91,14 @@
91 91  Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
92 92  
93 93  * Connect to the processor's console with Toolbox or your favorite SSH client.
94 -* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways.
95 -* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices.
96 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.
97 -* Type ##sr discover zummesh false## and press enter.
88 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
89 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
90 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.
91 +* Type "//sr discover zum false//" and press enter.
98 98  * Status messages and the results will be displayed on the console. The process should take about 3 minutes.
99 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
100 -* Type ##progreset## and press enter to restart SHOWRUNNER™
101 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
93 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
94 +* Type "//progreset//" and press enter to restart SHOWRUNNER™
95 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
102 102  * Once completed SHOWRUNNER™ is now ready for full Zūm control
103 103  
104 104  == Claim All RF Gateways Instructions ==
... ... @@ -106,11 +106,11 @@
106 106  Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.
107 107  
108 108  * Connect to the processor's console with Toolbox or your favorite SSH client.
109 -* Type ##sr discover zummesh true## and press enter.
103 +* Type "//sr discover zum true//" and press enter.
110 110  * Status messages and the results will be displayed on the console. The process should take about 3 minutes.
111 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
112 -* Type ##progreset## and press enter to restart SHOWRUNNER™
113 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
105 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
106 +* Type "//progreset//" and press enter to restart SHOWRUNNER™
107 +* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
114 114  * Once completed SHOWRUNNER™ is now ready for full Zūm control
115 115  
116 116  == Examples ==
... ... @@ -134,7 +134,7 @@
134 134  MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
135 135  Claimed ethernet device: CEN-GWEXER-9E6ADA
136 136  MC4>Update request from IP-ID-30 in Program 01
137 -MC4>sr discover zummesh false
131 +MC4>sr discover zum false
138 138  Starting Zum Discovery without gateway claiming
139 139  MC4>Performing Discovery on 1 Gateways.
140 140  Evaluating 3 Devices on Gateway 30
... ... @@ -167,7 +167,7 @@
167 167  MC4>progreset
168 168  ...
169 169  CI ShowRunner startup completed successfully in 8072ms
170 -MC4>sr discover zummesh false
164 +MC4>sr discover zum false
171 171  Starting Zum Discovery without gateway claiming
172 172  MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable)
173 173  Performing Discovery on 1 Gateways.
... ... @@ -220,7 +220,7 @@
220 220  
221 221  === Claim All Example ===
222 222  
223 -{{{MC4>sr discover zummesh true
217 +{{{MC4>sr discover zum true
224 224  Starting Zum Discovery with gateway claiming
225 225  MC4>Found 1 Gateways to check.
226 226  Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
... ... @@ -256,7 +256,7 @@
256 256  MC4>progreset
257 257  ...
258 258  CI ShowRunner startup completed successfully in 8072ms
259 -MC4>sr discover zummesh false
253 +MC4>sr discover zum false
260 260  Starting Zum Discovery without gateway claiming
261 261  MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable)
262 262  Performing Discovery on 1 Gateways.