Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
To version 9.1
edited by Alexander Mott
on 2022/10/05 16:17
on 2022/10/05 16:17
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,11 +18,14 @@ 18 18 19 19 == Notes and Limitations == 20 20 21 +(% class="box errormessage" %) 22 +((( 21 21 * SHOWRUNNER™ version 3.014 or newer required 22 22 * Zūm Wired firmware version 1.02.10 or greater required 23 23 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 24 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 25 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 28 +))) 26 26 27 27 == Steps == 28 28 ... ... @@ -61,9 +61,12 @@ 61 61 = Zūm Wireless Discovery = 62 62 63 63 == Notes and Limitations == 67 +))) 64 64 69 +(% class="box errormessage" %) 70 +((( 65 65 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 66 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zum mesh##72 +** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 67 67 * ZUM-NETBRIDGES must already be acquired to their respective gateway 68 68 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 69 69 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -85,14 +85,14 @@ 85 85 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 86 86 87 87 * Connect to the processor's console with Toolbox or your favorite SSH client. 88 -* Type "//sr devmgr ethernet query//"and press enter. This queries the local network for RF Gateways.89 -* Type "//sr devmgr ethernet show devices//"and press enter. This displays all found Crestron ethernet devices.90 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.91 -* Type "//sr discover zum false//"and press enter.94 +* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 95 +* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 96 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 97 +* Type ##sr discover zummesh false## and press enter. 92 92 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 93 -* When the discovery is finished type "//sr save//"and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.94 -* Type "//progreset//"and press enter to restart SHOWRUNNER™95 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//"and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.99 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 100 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 101 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 96 96 * Once completed SHOWRUNNER™ is now ready for full Zūm control 97 97 98 98 == Claim All RF Gateways Instructions == ... ... @@ -100,11 +100,11 @@ 100 100 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 101 101 102 102 * Connect to the processor's console with Toolbox or your favorite SSH client. 103 -* Type "//sr discover zum true//"and press enter.109 +* Type ##sr discover zummesh true## and press enter. 104 104 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 105 -* When the discovery is finished type "//sr save//"and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.106 -* Type "//progreset//"and press enter to restart SHOWRUNNER™107 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//"and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.111 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 112 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 113 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 108 108 * Once completed SHOWRUNNER™ is now ready for full Zūm control 109 109 110 110 == Examples == ... ... @@ -128,7 +128,7 @@ 128 128 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 129 129 Claimed ethernet device: CEN-GWEXER-9E6ADA 130 130 MC4>Update request from IP-ID-30 in Program 01 131 -MC4>sr discover zum false 137 +MC4>sr discover zummesh false 132 132 Starting Zum Discovery without gateway claiming 133 133 MC4>Performing Discovery on 1 Gateways. 134 134 Evaluating 3 Devices on Gateway 30 ... ... @@ -161,7 +161,7 @@ 161 161 MC4>progreset 162 162 ... 163 163 CI ShowRunner startup completed successfully in 8072ms 164 -MC4>sr discover zum false 170 +MC4>sr discover zummesh false 165 165 Starting Zum Discovery without gateway claiming 166 166 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 167 167 Performing Discovery on 1 Gateways. ... ... @@ -214,7 +214,7 @@ 214 214 215 215 === Claim All Example === 216 216 217 -{{{MC4>sr discover zum true 223 +{{{MC4>sr discover zummesh true 218 218 Starting Zum Discovery with gateway claiming 219 219 MC4>Found 1 Gateways to check. 220 220 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -250,7 +250,7 @@ 250 250 MC4>progreset 251 251 ... 252 252 CI ShowRunner startup completed successfully in 8072ms 253 -MC4>sr discover zum false 259 +MC4>sr discover zummesh false 254 254 Starting Zum Discovery without gateway claiming 255 255 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 256 256 Performing Discovery on 1 Gateways.