Changes for page Zūm Discovery

Last modified by Austin Weygandt on 2025/05/02 20:21

From version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
Change comment: There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2022/09/22 21:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Discovery
1 +Zūm Autodiscovery
Content
... ... @@ -1,6 +1,6 @@
1 1  (% class="box warningmessage" %)
2 2  (((
3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
4 4  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
5 5  )))
6 6  
... ... @@ -10,69 +10,29 @@
10 10  
11 11  (% class="row" %)
12 12  (((
13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
13 +If Zūm Net devices have been configured using Crestron's Zūm App
14 14  
15 -There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
15 += m Wired =
16 16  
17 -= Zūm Wired Discovery =
17 +Lorem
18 18  
19 -== Notes and Limitations ==
19 += Zūm Wireless =
20 20  
21 -* SHOWRUNNER™ version 3.014 or newer required
22 -* Zūm Wired firmware version 1.02.10 or greater required
23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
24 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
25 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
26 26  
27 -== Steps ==
22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
23 +*Disconnect from the gateway before discovery as they cannot support multiple connections*
24 +*Plug loads do not appear in the UI*
28 28  
29 -1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary
30 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices.
31 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 
32 -1*. Connect to the first ZUMNET-JBOX in Toolbox
33 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
34 -1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
35 -1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
36 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated
37 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX
38 -1*. Repeat the above steps for all ZUMNET-JBOXs
39 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step
40 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App
41 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX
42 -1*. If firmware was out-of-date, then this step should have already been completed
43 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs
44 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
45 -1*. If firmware was out-of-date, then this step should have already been completed
46 -1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
47 -1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
48 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
49 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
50 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices
51 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox
52 -1. Run the command: ##sr discover zumnet true false##
53 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration
54 -1*. One area will be created per ZUMNET-JBOX
55 -1. Run the command: ##sr discover zumnet true true##
56 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices
57 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
58 -1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™
59 -1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
26 +== Pre-Requisites: ==
60 60  
61 -= Zūm Wireless Discovery =
62 -
63 -== Notes and Limitations ==
64 -
65 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
66 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh##
67 -* ZUM-NETBRIDGES must already be acquired to their respective gateway
68 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
69 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
70 -* Plug loads will not appear in the SHOWRUNNER™ UI
28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway
30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored.
71 71  )))
72 72  
73 73  (% class="box warningmessage" id="HCaution:" %)
74 74  (((
75 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
35 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery
76 76  
77 77  1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
78 78  1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.
... ... @@ -80,37 +80,38 @@
80 80  
81 81  (% class="row" %)
82 82  (((
83 -== Manual RF Gateway Assignment Instructions ==
43 +== Option 1: Manual RF Gateway Claiming: ==
84 84  
85 -Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
45 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems.
86 86  
87 87  * Connect to the processor's console with Toolbox or your favorite SSH client.
88 88  * Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
89 89  * Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
90 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.
50 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step.
91 91  * Type "//sr discover zum false//" and press enter.
92 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
93 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
94 -* Type "//progreset//" and press enter to restart SHOWRUNNER™
95 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
96 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
52 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
53 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
54 +* Type "//progreset//" and press enter to restart ShowRunner
55 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
56 +* Once completed ShowRunner is now ready for full Zum control
97 97  
98 -== Claim All RF Gateways Instructions ==
58 +== Option 2: Claim All Gateways: ==
99 99  
100 -Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.
60 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner.
101 101  
102 102  * Connect to the processor's console with Toolbox or your favorite SSH client.
103 103  * Type "//sr discover zum true//" and press enter.
104 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
105 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
106 -* Type "//progreset//" and press enter to restart SHOWRUNNER™
107 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
108 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
64 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
65 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
66 +* Type "//progreset//" and press enter to restart ShowRunner
67 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
68 +* Once completed ShowRunner is now ready for full Zum control
109 109  
110 110  == Examples ==
111 111  
112 -=== Manual Example ===
113 113  
73 +=== Example for Option 1: ===
74 +
114 114  {{{MC4>sr devmgr ethernet query
115 115  Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
116 116  MC4>sr devmgr ethernet show devices
... ... @@ -212,7 +212,7 @@
212 212  Removed Loads: 0
213 213  Zum Discovery Finished}}}
214 214  
215 -=== Claim All Example ===
176 +=== Example for Option 2: ===
216 216  
217 217  {{{MC4>sr discover zum true
218 218  Starting Zum Discovery with gateway claiming