Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
To version 3.1
edited by Alexander Mott
on 2022/09/22 21:47
on 2022/09/22 21:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Content
-
... ... @@ -1,6 +1,6 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -10,127 +10,70 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 -If Zūm Wiredor Wirelessdevices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.13 +If Zūm Net devices have been configured using Crestron's Zūm App 14 14 15 - Thereare certain pre-requisites and limitationswhen building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 16 16 17 - = Zūm Wired Discovery =17 +Lorem 18 18 19 -= =Notesand Limitations ==19 += Zūm Wireless = 20 20 21 -* SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware version 1.02.10 or greater required 23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 26 26 27 -== Steps == 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 28 28 29 -1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 30 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 31 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 32 -1*. Connect to the first ZUMNET-JBOX in Toolbox 33 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 34 -1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 35 -1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 36 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 37 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 38 -1*. Repeat the above steps for all ZUMNET-JBOXs 39 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 40 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 41 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 42 -1*. If firmware was out-of-date, then this step should have already been completed 43 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 44 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 45 -1*. If firmware was out-of-date, then this step should have already been completed 46 -1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 47 -1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 48 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 49 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 50 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 51 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 52 -1. Run the command: ##sr discover zumnet true false## 53 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 -1*. One area will be created per ZUMNET-JBOX 55 -1. Run the command: ##sr discover zumnet true true## 56 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 57 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 58 -1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 -1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 26 +== Pre-Requisites: == 60 60 61 -= Zūm Wireless Discovery = 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 62 62 63 -== Notes and Limitations == 64 - 65 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 66 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 67 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 68 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 69 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 70 -* Plug loads will not appear in the SHOWRUNNER™ UI 71 -))) 72 - 73 73 (% class="box warningmessage" id="HCaution:" %) 74 74 ((( 75 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 76 - 77 -1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 78 -1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 34 +**Note,** SHOWRUNNER has two different types of Zum Wireless autodiscovery: 35 +1. Claim All RF Gateways - ShowRunner will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. DO NOT use this method if there are gateways used by different ShowRunner or other Crestron systems on the same local network. 36 +1. Manual RF Gateway Assignment - ShowRunner can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 79 79 ))) 80 80 81 -(% class="row" %) 82 -((( 83 -== Manual RF Gateway Assignment Instructions == 39 +== Option 1: Claim All Gateways: == 84 84 85 -Use this method ifyou havemultiple SHOWRUNNER™instancesonthesamenetworkorhavegateways usedbyotherCrestronsystems.41 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 86 86 87 87 * Connect to the processor's console with Toolbox or your favorite SSH client. 88 -* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 89 -* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 90 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 91 -* Type "//sr discover zum false//" and press enter. 92 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 93 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 94 -* Type "//progreset//" and press enter to restart SHOWRUNNER™ 95 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 96 -* Once completed SHOWRUNNER™ is now ready for full Zūm control 44 +* Type "//sr discover zum true//" and press enter. 45 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 46 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 47 +* Type "//progreset//" and press enter to restart ShowRunner 48 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 49 +* Once completed ShowRunner is now ready for full Zum control 97 97 98 -== ClaimAllRF GatewaysInstructions==51 +== Option 2: Manual RF Gateway Claiming: == 99 99 100 -Use this method whenyou havea single SHOWRUNNER™instance onalocalnetworkwithallgatewaysbeingusedforSHOWRUNNER™.53 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 101 101 102 102 * Connect to the processor's console with Toolbox or your favorite SSH client. 103 -* Type "//sr discover zum true//" and press enter. 104 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 105 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 106 -* Type "//progreset//" and press enter to restart SHOWRUNNER™ 107 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 108 -* Once completed SHOWRUNNER™ is now ready for full Zūm control 56 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 57 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 58 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 59 +* Type "//sr discover zum false//" and press enter. 60 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 61 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 62 +* Type "//progreset//" and press enter to restart ShowRunner 63 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 64 +* Once completed ShowRunner is now ready for full Zum control 109 109 110 110 == Examples == 111 111 112 -=== ManualExample ===68 +=== Example for Option 1: === 113 113 114 -{{{MC4>sr devmgr ethernet query 115 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 116 -MC4>sr devmgr ethernet show devices 117 - 118 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 119 -| Adapter | Hostname | IP Address | IP-ID | ID | 120 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 121 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 122 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 123 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 124 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 125 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 126 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 127 - 128 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 129 -Claimed ethernet device: CEN-GWEXER-9E6ADA 130 -MC4>Update request from IP-ID-30 in Program 01 131 -MC4>sr discover zum false 132 -Starting Zum Discovery without gateway claiming 133 -MC4>Performing Discovery on 1 Gateways. 70 +{{{MC4>sr discover zum true 71 +Starting Zum Discovery with gateway claiming 72 +MC4>Found 1 Gateways to check. 73 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 74 +Update request from IP-ID-30 in Program 01 75 +Claimed 1 Gateways. Waiting for queries to finish. 76 +Performing Discovery on 1 Gateways. 134 134 Evaluating 3 Devices on Gateway 30 135 135 Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 136 136 Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 ... ... @@ -141,7 +141,6 @@ 141 141 Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 142 142 Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 143 143 Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 144 -Querying cresnet 145 145 Discovering Zum Loads on 1 Gateways. 146 146 Discovering Zum Loads on 3 Devices. 147 147 NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 ... ... @@ -210,17 +210,31 @@ 210 210 New Loads: 6 211 211 Modified Loads: 0 212 212 Removed Loads: 0 213 -Zum Discovery Finished}}} 155 +Zum Discovery Finished 156 +}}} 214 214 215 -=== Claim AllExample ===158 +=== Example for Option 2: === 216 216 217 -{{{MC4>sr discover zum true 218 -Starting Zum Discovery with gateway claiming 219 -MC4>Found 1 Gateways to check. 220 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 221 -Update request from IP-ID-30 in Program 01 222 -Claimed 1 Gateways. Waiting for queries to finish. 223 -Performing Discovery on 1 Gateways. 160 +{{{MC4>sr devmgr ethernet query 161 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 162 +MC4>sr devmgr ethernet show devices 163 + 164 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 165 +| Adapter | Hostname | IP Address | IP-ID | ID | 166 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 167 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 168 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 169 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 170 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 171 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 172 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 173 + 174 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 175 +Claimed ethernet device: CEN-GWEXER-9E6ADA 176 +MC4>Update request from IP-ID-30 in Program 01 177 +MC4>sr discover zum false 178 +Starting Zum Discovery without gateway claiming 179 +MC4>Performing Discovery on 1 Gateways. 224 224 Evaluating 3 Devices on Gateway 30 225 225 Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 226 226 Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 ... ... @@ -231,6 +231,7 @@ 231 231 Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 232 232 Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 233 233 Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 190 +Querying cresnet 234 234 Discovering Zum Loads on 1 Gateways. 235 235 Discovering Zum Loads on 3 Devices. 236 236 NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 ... ... @@ -300,5 +300,5 @@ 300 300 Modified Loads: 0 301 301 Removed Loads: 0 302 302 Zum Discovery Finished 303 -}}} 260 + }}} 304 304 )))