Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
To version 24.2
edited by Craig Lewis
on 2024/05/22 21:45
on 2024/05/22 21:45
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. DeviceAddressing.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. alexander\.mott@chiefintegrations\.com1 +XWiki.craig\.lewis@chiefintegrations\.com - Content
-
... ... @@ -1,6 +1,14 @@ 1 +(% class="box errormessage" %) 2 +((( 3 +**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 + 5 +**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 +ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 +))) 8 + 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a S HOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.WiringGuide.Zūm Wired System Overview.Crestron11 +This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -8,104 +8,111 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -(% class="row" %) 12 -((( 13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 19 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 14 14 15 -There are certain pre-requisites and limitations when building a S HOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.21 +There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 17 = Zūm Wired Discovery = 18 18 19 19 == Notes and Limitations == 20 20 21 -* SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware version 1.02.10 or greater required 27 +(% class="box warningmessage" %) 28 +((( 29 +* ShowRunnerCLC™ version 3.014 or newer required 30 +* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 23 23 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 24 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 25 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 34 +))) 26 26 27 27 == Steps == 28 28 29 -1. [[Install S HOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary38 +1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 30 30 1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 31 31 1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 32 32 1*. Connect to the first ZUMNET-JBOX in Toolbox 33 33 1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 34 -1**. Note: The S HOWRUNNER™ built-in DHCP server is not meant to be used in production35 -1**. If the S HOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses43 +1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 44 +1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 36 36 1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 37 37 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 38 38 1*. Repeat the above steps for all ZUMNET-JBOXs 39 39 1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 40 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 49 +1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 50 +1*. Commission room through the app 51 +1**. configure keypad logic 52 +1**. configure occupancy sensor settings 53 +1**. calibrate photocell(s) 54 +1*. Set hostnames for the ZUMNETs for easy identification when hardware is discovered. 41 41 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 42 42 1*. If firmware was out-of-date, then this step should have already been completed 43 43 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 44 44 1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 45 45 1*. If firmware was out-of-date, then this step should have already been completed 46 -1*. Note: The S HOWRUNNER™ built-in DHCP server is not meant to be used in production47 -1*. If the S HOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses60 +1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 61 +1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 48 48 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 49 49 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 50 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 64 +1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 65 +1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 66 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 51 51 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 52 52 1. Run the command: ##sr discover zumnet true false## 53 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 -1*. One area will be created per ZUMNET-JBOX 69 +1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 55 55 1. Run the command: ##sr discover zumnet true true## 56 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 71 +1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 72 +1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 57 57 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 58 -1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 -1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 74 +1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 60 60 61 61 = Zūm Wireless Discovery = 62 62 63 63 == Notes and Limitations == 64 64 65 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 66 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 80 +(% class="box warningmessage" %) 81 +((( 82 +* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 83 +** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 67 67 * ZUM-NETBRIDGES must already be acquired to their respective gateway 68 -* S HOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices85 +* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 69 69 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 70 -* Plug loads will not appear in the S HOWRUNNER™ UI87 +* Plug loads will not appear in the ShowRunnerCLC™ UI 71 71 ))) 72 72 73 -(% class="box warningmessage" id="HCaution:" %)90 +(% class="box infomessage" id="HCaution:" %) 74 74 ((( 75 -**Note:** S HOWRUNNER™ has two different approaches for Zūm Wireless Discovery92 +**Note:** ShowRunnerCLC™ has two different approaches for Zūm Wireless Discovery 76 76 77 -1. **Manual RF Gateway Assignment** - S HOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.78 -1. **Claim All RF Gateways** - S HOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.94 +1. **Manual RF Gateway Assignment** - ShowRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 95 +1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network. 79 79 ))) 80 80 81 -(% class="row" %) 82 -((( 83 83 == Manual RF Gateway Assignment Instructions == 84 84 85 -Use this method if you have multiple S HOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.100 +Use this method if you have multiple ShowRunnerCLC™ instances on the same network or have gateways used by other Crestron systems. 86 86 87 87 * Connect to the processor's console with Toolbox or your favorite SSH client. 88 -* Type "//sr devmgr ethernet query//"and press enter. This queries the local network for RF Gateways.89 -* Type "//sr devmgr ethernet show devices//"and press enter. This displays all found Crestron ethernet devices.90 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.91 -* Type "//sr discover zum false//"and press enter.103 +* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 104 +* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 105 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step. 106 +* Type ##sr discover zummesh false## and press enter. 92 92 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 93 -* When the discovery is finished type "//sr save//"and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.94 -* Type "//progreset//"and press enter to restart SHOWRUNNER™95 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//"and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.108 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 109 +* Type ##progreset## and press enter to restart ShowRunnerCLC™ 110 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 96 96 * Once completed SHOWRUNNER™ is now ready for full Zūm control 97 97 98 98 == Claim All RF Gateways Instructions == 99 99 100 -Use this method when you have a single S HOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.115 +Use this method when you have a single ShowRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™. 101 101 102 102 * Connect to the processor's console with Toolbox or your favorite SSH client. 103 -* Type "//sr discover zum true//"and press enter.118 +* Type ##sr discover zummesh true## and press enter. 104 104 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 105 -* When the discovery is finished type "//sr save//"and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.106 -* Type "//progreset//"and press enter to restart SHOWRUNNER™107 -* Once S HOWRUNNER™ has finished restarting type"//sr discover zum false//"and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.108 -* Once completed S HOWRUNNER™ is now ready for full Zūm control120 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 121 +* Type ##progreset## and press enter to restart ShowRunnerCLC™ 122 +* Once ShowRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 123 +* Once completed ShowRunnerCLC™ is now ready for full Zūm control 109 109 110 110 == Examples == 111 111 ... ... @@ -128,7 +128,7 @@ 128 128 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 129 129 Claimed ethernet device: CEN-GWEXER-9E6ADA 130 130 MC4>Update request from IP-ID-30 in Program 01 131 -MC4>sr discover zum false 146 +MC4>sr discover zummesh false 132 132 Starting Zum Discovery without gateway claiming 133 133 MC4>Performing Discovery on 1 Gateways. 134 134 Evaluating 3 Devices on Gateway 30 ... ... @@ -161,7 +161,7 @@ 161 161 MC4>progreset 162 162 ... 163 163 CI ShowRunner startup completed successfully in 8072ms 164 -MC4>sr discover zum false 179 +MC4>sr discover zummesh false 165 165 Starting Zum Discovery without gateway claiming 166 166 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 167 167 Performing Discovery on 1 Gateways. ... ... @@ -214,7 +214,7 @@ 214 214 215 215 === Claim All Example === 216 216 217 -{{{MC4>sr discover zum true 232 +{{{MC4>sr discover zummesh true 218 218 Starting Zum Discovery with gateway claiming 219 219 MC4>Found 1 Gateways to check. 220 220 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -250,7 +250,7 @@ 250 250 MC4>progreset 251 251 ... 252 252 CI ShowRunner startup completed successfully in 8072ms 253 -MC4>sr discover zum false 268 +MC4>sr discover zummesh false 254 254 Starting Zum Discovery without gateway claiming 255 255 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 256 256 Performing Discovery on 1 Gateways. ... ... @@ -301,4 +301,3 @@ 301 301 Removed Loads: 0 302 302 Zum Discovery Finished 303 303 }}} 304 -)))