Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 7.1
edited by Alexander Mott
on 2022/09/22 23:59
Change comment: There is no comment for this version
To version 6.7
edited by Alexander Mott
on 2022/09/22 23:57
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -26,36 +26,7 @@
26 26  
27 27  == Steps ==
28 28  
29 -1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary
30 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices.
31 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 
32 -1*. Connect to the first ZUMNET-JBOX in Toolbox
33 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
34 -1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
35 -1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
36 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated
37 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX
38 -1*. Repeat the above steps for all ZUMNET-JBOXs
39 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, proceed to the next step
40 -1. Connect to first ZUMNET-JBOX in the Crestron Zūm App
41 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX
42 -1*. If firmware was out-of-date, then this step should have already been completed
43 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs
44 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
45 -1*. If firmware was out-of-date, then this step should have already been completed
46 -1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production
47 -1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
48 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
49 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
50 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices
51 -1. Connect to the processor in Toolbox and run the command: ##sr discover zumnet true false##
52 -1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration
53 -1*. One area will be created per ZUMNET-JBOX
54 -1. Run the command: ##sr discover zumnet true true##
55 -1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices
56 -1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware
57 -1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™
58 -1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
29 +1.
59 59  
60 60  = Zūm Wireless Discovery =
61 61