Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
To version 11.1
edited by Alexander Mott
on 2022/10/05 16:19
on 2022/10/05 16:19
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,8 +8,6 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -(% class="row" %) 12 -((( 13 13 If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 14 14 15 15 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. ... ... @@ -18,22 +18,57 @@ 18 18 19 19 == Notes and Limitations == 20 20 19 +(% class="box errormessage" %) 20 +((( 21 21 * SHOWRUNNER™ version 3.014 or newer required 22 22 * Zūm Wired firmware version 1.02.10 or greater required 23 23 * Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 24 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 25 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 26 +))) 26 26 27 27 == Steps == 28 28 29 -1. 30 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 31 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 32 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 33 +1*. Connect to the first ZUMNET-JBOX in Toolbox 34 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 35 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 36 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 37 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 38 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 39 +1*. Repeat the above steps for all ZUMNET-JBOXs 40 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 41 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 42 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 43 +1*. If firmware was out-of-date, then this step should have already been completed 44 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 45 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 46 +1*. If firmware was out-of-date, then this step should have already been completed 47 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 48 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 49 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 50 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 51 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 52 +1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 53 +1. Run the command: ##sr discover zumnet true false## 54 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 55 +1*. One area will be created per ZUMNET-JBOX 56 +1. Run the command: ##sr discover zumnet true true## 57 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 58 +1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 59 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 60 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 30 30 31 31 = Zūm Wireless Discovery = 32 32 33 33 == Notes and Limitations == 34 34 66 +(% class="box errormessage" %) 67 +((( 35 35 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 36 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zum mesh##69 +** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 37 37 * ZUM-NETBRIDGES must already be acquired to their respective gateway 38 38 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 39 39 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -48,21 +48,19 @@ 48 48 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 49 49 ))) 50 50 51 -(% class="row" %) 52 -((( 53 53 == Manual RF Gateway Assignment Instructions == 54 54 55 55 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 56 56 57 57 * Connect to the processor's console with Toolbox or your favorite SSH client. 58 -* Type "//sr devmgr ethernet query//"and press enter. This queries the local network for RF Gateways.59 -* Type "//sr devmgr ethernet show devices//"and press enter. This displays all found Crestron ethernet devices.60 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.61 -* Type "//sr discover zum false//"and press enter.89 +* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 90 +* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 91 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 92 +* Type ##sr discover zummesh false## and press enter. 62 62 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 63 -* When the discovery is finished type "//sr save//"and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.64 -* Type "//progreset//"and press enter to restart SHOWRUNNER™65 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//"and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.94 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 95 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 96 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 66 66 * Once completed SHOWRUNNER™ is now ready for full Zūm control 67 67 68 68 == Claim All RF Gateways Instructions == ... ... @@ -70,11 +70,11 @@ 70 70 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 71 71 72 72 * Connect to the processor's console with Toolbox or your favorite SSH client. 73 -* Type "//sr discover zum true//"and press enter.104 +* Type ##sr discover zummesh true## and press enter. 74 74 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 75 -* When the discovery is finished type "//sr save//"and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.76 -* Type "//progreset//"and press enter to restart SHOWRUNNER™77 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//"and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.106 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 107 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 108 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 78 78 * Once completed SHOWRUNNER™ is now ready for full Zūm control 79 79 80 80 == Examples == ... ... @@ -98,7 +98,7 @@ 98 98 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 99 99 Claimed ethernet device: CEN-GWEXER-9E6ADA 100 100 MC4>Update request from IP-ID-30 in Program 01 101 -MC4>sr discover zum false 132 +MC4>sr discover zummesh false 102 102 Starting Zum Discovery without gateway claiming 103 103 MC4>Performing Discovery on 1 Gateways. 104 104 Evaluating 3 Devices on Gateway 30 ... ... @@ -131,7 +131,7 @@ 131 131 MC4>progreset 132 132 ... 133 133 CI ShowRunner startup completed successfully in 8072ms 134 -MC4>sr discover zum false 165 +MC4>sr discover zummesh false 135 135 Starting Zum Discovery without gateway claiming 136 136 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 137 137 Performing Discovery on 1 Gateways. ... ... @@ -184,7 +184,7 @@ 184 184 185 185 === Claim All Example === 186 186 187 -{{{MC4>sr discover zum true 218 +{{{MC4>sr discover zummesh true 188 188 Starting Zum Discovery with gateway claiming 189 189 MC4>Found 1 Gateways to check. 190 190 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -220,7 +220,7 @@ 220 220 MC4>progreset 221 221 ... 222 222 CI ShowRunner startup completed successfully in 8072ms 223 -MC4>sr discover zum false 254 +MC4>sr discover zummesh false 224 224 Starting Zum Discovery without gateway claiming 225 225 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 226 226 Performing Discovery on 1 Gateways. ... ... @@ -271,4 +271,3 @@ 271 271 Removed Loads: 0 272 272 Zum Discovery Finished 273 273 }}} 274 -)))