Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 6.2
edited by Alexander Mott
on 2022/09/22 23:32
on 2022/09/22 23:32
Change comment:
There is no comment for this version
To version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
on 2022/09/22 22:11
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,39 +10,34 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™. 14 14 15 15 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 17 = Zūm Wired Discovery = 18 18 19 - == Notes and Limitations ==19 +Lorem 20 20 21 -* SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware version 1.02.10 or greater required 23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 21 += Zūm Wireless Discovery = 26 26 27 -== Steps == 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 28 28 29 - 1.26 +== Notes and Limitations == 30 30 31 -= Zūm Wireless Discovery = 28 +* SHOWRUNNER™ version 2.190 or newer required 29 +* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command, 32 32 33 -== Notesand Limitations ==31 +== Pre-Requisites == 34 34 35 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 36 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 37 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 38 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 39 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 40 -* Plug loads will not appear in the SHOWRUNNER™ UI 33 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 34 +* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway 35 +* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored. 41 41 ))) 42 42 43 43 (% class="box warningmessage" id="HCaution:" %) 44 44 ((( 45 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery40 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 46 46 47 47 1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 48 48 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. ... ... @@ -50,7 +50,7 @@ 50 50 51 51 (% class="row" %) 52 52 ((( 53 -== Manual RF Gateway Assignment Instructions==48 +== Manual RF Gateway Assignment == 54 54 55 55 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 56 56 ... ... @@ -65,7 +65,7 @@ 65 65 * Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 66 66 * Once completed SHOWRUNNER™ is now ready for full Zūm control 67 67 68 -== Claim All RF Gateways Instructions==63 +== Claim All RF Gateways == 69 69 70 70 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 71 71