Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 6.2
edited by Alexander Mott
on 2022/09/22 23:32
Change comment: There is no comment for this version
To version 5.1
edited by Alexander Mott
on 2022/09/22 21:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Discovery
1 +Zūm Autodiscovery
Content
... ... @@ -1,6 +1,6 @@
1 1  (% class="box warningmessage" %)
2 2  (((
3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
4 4  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
5 5  )))
6 6  
... ... @@ -10,39 +10,28 @@
10 10  
11 11  (% class="row" %)
12 12  (((
13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
13 +If Zūm Net devices have been configured using Crestron's Zūm App
14 14  
15 -There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
15 += m Wired =
16 16  
17 -= Zūm Wired Discovery =
17 +Lorem
18 18  
19 -== Notes and Limitations ==
19 += Zūm Wireless =
20 20  
21 -* SHOWRUNNER™ version 3.014 or newer required
22 -* Zūm Wired firmware version 1.02.10 or greater required
23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands
24 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
25 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
21 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
22 +*Disconnect from the gateway before discovery as they cannot support multiple connections*
23 +*Plug loads do not appear in the UI*
26 26  
27 -== Steps ==
25 +== Pre-Requisites: ==
28 28  
29 -1.
30 -
31 -= Zūm Wireless Discovery =
32 -
33 -== Notes and Limitations ==
34 -
35 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
36 -** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh##
37 -* ZUM-NETBRIDGES must already be acquired to their respective gateway
38 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
39 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
40 -* Plug loads will not appear in the SHOWRUNNER™ UI
27 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
28 +* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway
29 +* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored.
41 41  )))
42 42  
43 43  (% class="box warningmessage" id="HCaution:" %)
44 44  (((
45 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
34 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery
46 46  
47 47  1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
48 48  1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.
... ... @@ -50,7 +50,7 @@
50 50  
51 51  (% class="row" %)
52 52  (((
53 -== Manual RF Gateway Assignment Instructions ==
42 +== Manual RF Gateway Claiming ==
54 54  
55 55  Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
56 56  
... ... @@ -65,7 +65,7 @@
65 65  * Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
66 66  * Once completed SHOWRUNNER™ is now ready for full Zūm control
67 67  
68 -== Claim All RF Gateways Instructions ==
57 +== Claim All RF Gateways ==
69 69  
70 70  Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.
71 71  
... ... @@ -79,7 +79,7 @@
79 79  
80 80  == Examples ==
81 81  
82 -=== Manual Example ===
71 +=== Claim Selectively (Manual) Example ===
83 83  
84 84  {{{MC4>sr devmgr ethernet query
85 85  Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess