Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 6.1
edited by Alexander Mott
on 2022/09/22 23:12
on 2022/09/22 23:12
Change comment:
There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/09/23 00:00
on 2022/09/23 00:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,14 +19,51 @@ 19 19 == Notes and Limitations == 20 20 21 21 * SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware version 23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery command 22 +* Zūm Wired firmware version 1.02.10 or greater required 23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 24 24 27 +== Steps == 28 + 29 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 30 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 31 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 32 +1*. Connect to the first ZUMNET-JBOX in Toolbox 33 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 34 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 35 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 36 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 37 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 38 +1*. Repeat the above steps for all ZUMNET-JBOXs 39 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 40 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 41 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 42 +1*. If firmware was out-of-date, then this step should have already been completed 43 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 44 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 45 +1*. If firmware was out-of-date, then this step should have already been completed 46 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 47 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 48 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 49 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 50 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 51 +1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 52 +1. Run the command: ##sr discover zumnet true false## 53 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 54 +1*. One area will be created per ZUMNET-JBOX 55 +1. Run the command: ##sr discover zumnet true true## 56 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 57 +1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 58 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 59 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 60 + 25 25 = Zūm Wireless Discovery = 26 26 27 27 == Notes and Limitations == 28 28 29 29 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 66 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 30 30 * ZUM-NETBRIDGES must already be acquired to their respective gateway 31 31 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 32 32 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -43,7 +43,7 @@ 43 43 44 44 (% class="row" %) 45 45 ((( 46 -== Manual RF Gateway Assignment == 83 +== Manual RF Gateway Assignment Instructions == 47 47 48 48 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 49 49 ... ... @@ -58,7 +58,7 @@ 58 58 * Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 59 59 * Once completed SHOWRUNNER™ is now ready for full Zūm control 60 60 61 -== Claim All RF Gateways == 98 +== Claim All RF Gateways Instructions == 62 62 63 63 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 64 64