Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 6.1
edited by Alexander Mott
on 2022/09/22 23:12
on 2022/09/22 23:12
Change comment:
There is no comment for this version
To version 6.2
edited by Alexander Mott
on 2022/09/22 23:32
on 2022/09/22 23:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,14 +19,21 @@ 19 19 == Notes and Limitations == 20 20 21 21 * SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware version 23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery command 22 +* Zūm Wired firmware version 1.02.10 or greater required 23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 24 24 27 +== Steps == 28 + 29 +1. 30 + 25 25 = Zūm Wireless Discovery = 26 26 27 27 == Notes and Limitations == 28 28 29 29 * Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 36 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 30 30 * ZUM-NETBRIDGES must already be acquired to their respective gateway 31 31 * SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 32 32 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command ... ... @@ -43,7 +43,7 @@ 43 43 44 44 (% class="row" %) 45 45 ((( 46 -== Manual RF Gateway Assignment == 53 +== Manual RF Gateway Assignment Instructions == 47 47 48 48 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 49 49 ... ... @@ -58,7 +58,7 @@ 58 58 * Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 59 59 * Once completed SHOWRUNNER™ is now ready for full Zūm control 60 60 61 -== Claim All RF Gateways == 68 +== Claim All RF Gateways Instructions == 62 62 63 63 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 64 64