13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.
14 14  
15 15  There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
16 16  
17 17  = Zūm Wired Discovery =
18 18  
19 -== Notes and Limitations ==
19 +Lorem
20 20  
21 -* SHOWRUNNER™ version 3.014 or newer required
22 -* Zūm Wired firmware version
23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery command
24 -
25 25  = Zūm Wireless Discovery =
26 26  
23 +*Disconnect from the gateway before discovery as they cannot support multiple connections*
24 +*Plug loads do not appear in the UI*
25 +
27 27  == Notes and Limitations ==
28 28  
29 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
30 -* ZUM-NETBRIDGES must already be acquired to their respective gateway
31 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
32 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
33 -* Plug loads will not appear in the SHOWRUNNER™ UI
28 +* SHOWRUNNER™ version 2.190 or newer required
29 +* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command,
30 +
31 +== Pre-Requisites ==
32 +
33 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
34 +* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway
35 +* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored.
34 34  )))
35 35  
36 36  (% class="box warningmessage" id="HCaution:" %)
37 37  (((
38 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
40 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery
39 39  
40 40  1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
41 41  1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.