Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 6.1
edited by Alexander Mott
on 2022/09/22 23:12
on 2022/09/22 23:12
Change comment:
There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2022/09/22 21:50
on 2022/09/22 21:50
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Content
-
... ... @@ -1,6 +1,6 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -10,32 +10,29 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 -If Zūm Wiredor Wirelessdevices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.13 +If Zūm Net devices have been configured using Crestron's Zūm App 14 14 15 - Thereare certain pre-requisites and limitationswhen building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 16 16 17 - = Zūm Wired Discovery =17 +Lorem 18 18 19 -= =Notesand Limitations ==19 += Zūm Wireless = 20 20 21 -* SHOWRUNNER™ version 3.014 or newer required 22 -* Zūm Wired firmware version 23 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery command 24 24 25 -= Zūm Wireless Discovery = 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 26 26 27 -== Notesand Limitations ==26 +== Pre-Requisites: == 28 28 29 -* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 30 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 31 -* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 32 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 33 -* Plug loads will not appear in the SHOWRUNNER™ UI 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 34 34 ))) 35 35 36 36 (% class="box warningmessage" id="HCaution:" %) 37 37 ((( 38 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery35 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 39 39 40 40 1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 41 41 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. ... ... @@ -43,37 +43,38 @@ 43 43 44 44 (% class="row" %) 45 45 ((( 46 -== Manual RF Gateway Assignment==43 +== Option 1: Manual RF Gateway Claiming: == 47 47 48 -Use this method if you have multiple S HOWRUNNER™instances on the same network or have gateways used by other Crestron systems.45 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 49 49 50 50 * Connect to the processor's console with Toolbox or your favorite SSH client. 51 51 * Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 52 52 * Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 53 -* For each gateway that you'd like this instance of S HOWRUNNER™to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™,proceed to the next step.50 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 54 54 * Type "//sr discover zum false//" and press enter. 55 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 56 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. HOWRUNNER™must be restarted to complete the acquire process.57 -* Type "//progreset//" and press enter to restart S HOWRUNNER™58 -* Once S HOWRUNNER™has finished restarting type "//sr discover zum false//" and press enter.HOWRUNNER™will be able to acquire the loads attached to the Zūm rooms at this point.59 -* Once completed S HOWRUNNER™is now ready for full Zūm control52 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 53 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 54 +* Type "//progreset//" and press enter to restart ShowRunner 55 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 56 +* Once completed ShowRunner is now ready for full Zum control 60 60 61 -== Claim All RFGateways ==58 +== Option 2: Claim All Gateways: == 62 62 63 -Use this method when you have a single S HOWRUNNER™instance on a local network with all gateways being used for SHOWRUNNER™.60 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 64 64 65 65 * Connect to the processor's console with Toolbox or your favorite SSH client. 66 66 * Type "//sr discover zum true//" and press enter. 67 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 68 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, HOWRUNNER™must be restarted to complete the acquire process.69 -* Type "//progreset//" and press enter to restart S HOWRUNNER™70 -* Once S HOWRUNNER™has finished restarting type "//sr discover zum false//" and press enter.HOWRUNNER™will be able to acquire the loads attached to the Zūm rooms at this point.71 -* Once completed S HOWRUNNER™is now ready for full Zūm control64 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 65 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 66 +* Type "//progreset//" and press enter to restart ShowRunner 67 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 68 +* Once completed ShowRunner is now ready for full Zum control 72 72 73 73 == Examples == 74 74 75 -=== Manual Example === 76 76 73 +=== Example for Option 1: === 74 + 77 77 {{{MC4>sr devmgr ethernet query 78 78 Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 79 79 MC4>sr devmgr ethernet show devices ... ... @@ -175,7 +175,7 @@ 175 175 Removed Loads: 0 176 176 Zum Discovery Finished}}} 177 177 178 -=== Claim AllExample ===176 +=== Example for Option 2: === 179 179 180 180 {{{MC4>sr discover zum true 181 181 Starting Zum Discovery with gateway claiming