Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
on 2022/09/22 22:11
Change comment:
There is no comment for this version
To version 7.1
edited by Alexander Mott
on 2022/09/22 23:59
on 2022/09/22 23:59
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,34 +10,68 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 14 14 15 15 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 17 = Zūm Wired Discovery = 18 18 19 - Lorem19 +== Notes and Limitations == 20 20 21 -= Zūm Wireless Discovery = 21 +* SHOWRUNNER™ version 3.014 or newer required 22 +* Zūm Wired firmware version 1.02.10 or greater required 23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 24 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 25 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 22 22 23 -*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 -*Plug loads do not appear in the UI* 27 +== Steps == 25 25 26 -== Notes and Limitations == 29 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 30 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 31 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 32 +1*. Connect to the first ZUMNET-JBOX in Toolbox 33 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 34 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 35 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 36 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 37 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 38 +1*. Repeat the above steps for all ZUMNET-JBOXs 39 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, proceed to the next step 40 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 41 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 42 +1*. If firmware was out-of-date, then this step should have already been completed 43 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 44 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 45 +1*. If firmware was out-of-date, then this step should have already been completed 46 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 47 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 48 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 49 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 50 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 51 +1. Connect to the processor in Toolbox and run the command: ##sr discover zumnet true false## 52 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding areas and loads to the configuration 53 +1*. One area will be created per ZUMNET-JBOX 54 +1. Run the command: ##sr discover zumnet true true## 55 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware on the previously discovered Zūm Net devices 56 +1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 57 +1. Put all ZUMNET-JBOXs into CNET mode in order to allow full control from SHOWRUNNER™ 58 +1*. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 27 27 28 -* SHOWRUNNER™ version 2.190 or newer required 29 -* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command, 60 += Zūm Wireless Discovery = 30 30 31 -== Pre-Requisites ==62 +== Notes and Limitations == 32 32 33 -* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 34 -* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway 35 -* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored. 64 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 65 +** For SHOWRUNNER™ versions 3.014 and newer, replace ##sr discover zum## commands with ##sr discover zummesh## 66 +* ZUM-NETBRIDGES must already be acquired to their respective gateway 67 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 68 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 69 +* Plug loads will not appear in the SHOWRUNNER™ UI 36 36 ))) 37 37 38 38 (% class="box warningmessage" id="HCaution:" %) 39 39 ((( 40 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery74 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 41 41 42 42 1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 43 43 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. ... ... @@ -45,7 +45,7 @@ 45 45 46 46 (% class="row" %) 47 47 ((( 48 -== Manual RF Gateway Assignment == 82 +== Manual RF Gateway Assignment Instructions == 49 49 50 50 Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 51 51 ... ... @@ -60,7 +60,7 @@ 60 60 * Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 61 61 * Once completed SHOWRUNNER™ is now ready for full Zūm control 62 62 63 -== Claim All RF Gateways == 97 +== Claim All RF Gateways Instructions == 64 64 65 65 Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 66 66