Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
on 2022/09/22 22:11
Change comment:
There is no comment for this version
To version 6.1
edited by Alexander Mott
on 2022/09/22 23:12
on 2022/09/22 23:12
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,34 +10,32 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 14 14 15 15 There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 17 = Zūm Wired Discovery = 18 18 19 - Lorem19 +== Notes and Limitations == 20 20 21 +* SHOWRUNNER™ version 3.014 or newer required 22 +* Zūm Wired firmware version 23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery command 24 + 21 21 = Zūm Wireless Discovery = 22 22 23 -*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 -*Plug loads do not appear in the UI* 25 - 26 26 == Notes and Limitations == 27 27 28 -* SHOWRUNNER™ version 2.190 or newer required 29 -* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command, 30 - 31 -== Pre-Requisites == 32 - 33 -* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 34 -* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway 35 -* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored. 29 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 30 +* ZUM-NETBRIDGES must already be acquired to their respective gateway 31 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 32 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 33 +* Plug loads will not appear in the SHOWRUNNER™ UI 36 36 ))) 37 37 38 38 (% class="box warningmessage" id="HCaution:" %) 39 39 ((( 40 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery38 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 41 41 42 42 1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 43 43 1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.