Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
Change comment: There is no comment for this version
To version 6.1
edited by Alexander Mott
on 2022/09/22 23:12
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,34 +10,32 @@
10 10  
11 11  (% class="row" %)
12 12  (((
13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.
13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™.
14 14  
15 15  There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
16 16  
17 17  = Zūm Wired Discovery =
18 18  
19 -Lorem
19 +== Notes and Limitations ==
20 20  
21 +* SHOWRUNNER™ version 3.014 or newer required
22 +* Zūm Wired firmware version
23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery command
24 +
21 21  = Zūm Wireless Discovery =
22 22  
23 -*Disconnect from the gateway before discovery as they cannot support multiple connections*
24 -*Plug loads do not appear in the UI*
25 -
26 26  == Notes and Limitations ==
27 27  
28 -* SHOWRUNNER™ version 2.190 or newer required
29 -* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command,
30 -
31 -== Pre-Requisites ==
32 -
33 -* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
34 -* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway
35 -* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored.
29 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
30 +* ZUM-NETBRIDGES must already be acquired to their respective gateway
31 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
32 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
33 +* Plug loads will not appear in the SHOWRUNNER™ UI
36 36  )))
37 37  
38 38  (% class="box warningmessage" id="HCaution:" %)
39 39  (((
40 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery
38 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery
41 41  
42 42  1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
43 43  1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.