Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
Change comment: There is no comment for this version
To version 3.1
edited by Alexander Mott
on 2022/09/22 21:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Discovery
1 +Zūm Autodiscovery
Content
... ... @@ -1,6 +1,6 @@
1 1  (% class="box warningmessage" %)
2 2  (((
3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
4 4  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
5 5  )))
6 6  
... ... @@ -10,92 +10,70 @@
10 10  
11 11  (% class="row" %)
12 12  (((
13 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.
13 +If Zūm Net devices have been configured using Crestron's Zūm App
14 14  
15 -There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
15 += m Wired =
16 16  
17 -= Zūm Wired Discovery =
18 -
19 19  Lorem
20 20  
21 -= Zūm Wireless Discovery =
19 += Zūm Wireless =
22 22  
21 +
22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
23 23  *Disconnect from the gateway before discovery as they cannot support multiple connections*
24 24  *Plug loads do not appear in the UI*
25 25  
26 -== Notes and Limitations ==
26 +== Pre-Requisites: ==
27 27  
28 -* SHOWRUNNER™ version 2.190 or newer required
29 -* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command,
30 -
31 -== Pre-Requisites ==
32 -
33 33  * Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
34 -* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway
35 -* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored.
36 -)))
29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway
30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored.
37 37  
38 38  (% class="box warningmessage" id="HCaution:" %)
39 39  (((
40 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery
41 -
42 -1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
43 -1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.
34 +**Note,** SHOWRUNNER has two different types of Zum Wireless autodiscovery:
35 +1. Claim All RF Gateways - ShowRunner will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own.  DO NOT use this method if there are gateways used by different ShowRunner or other Crestron systems on the same local network.
36 +1. Manual RF Gateway Assignment - ShowRunner can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
44 44  )))
45 45  
46 -(% class="row" %)
47 -(((
48 -== Manual RF Gateway Assignment ==
39 +== Option 1: Claim All Gateways: ==
49 49  
50 -Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
41 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner.
51 51  
52 52  * Connect to the processor's console with Toolbox or your favorite SSH client.
53 -* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
54 -* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
55 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step.
56 -* Type "//sr discover zum false//" and press enter.
57 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
58 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
59 -* Type "//progreset//" and press enter to restart SHOWRUNNER™
60 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
61 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
44 +* Type "//sr discover zum true//" and press enter.
45 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
46 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
47 +* Type "//progreset//" and press enter to restart ShowRunner
48 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
49 +* Once completed ShowRunner is now ready for full Zum control
62 62  
63 -== Claim All RF Gateways ==
51 +== Option 2: Manual RF Gateway Claiming: ==
64 64  
65 -Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™.
53 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems.
66 66  
67 67  * Connect to the processor's console with Toolbox or your favorite SSH client.
68 -* Type "//sr discover zum true//" and press enter.
69 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
70 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process.
71 -* Type "//progreset//" and press enter to restart SHOWRUNNER™
72 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point.
73 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
56 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
57 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
58 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step.
59 +* Type "//sr discover zum false//" and press enter.
60 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
61 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
62 +* Type "//progreset//" and press enter to restart ShowRunner
63 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
64 +* Once completed ShowRunner is now ready for full Zum control
74 74  
75 75  == Examples ==
76 76  
77 -=== Manual Example ===
68 +=== Example for Option 1: ===
78 78  
79 -{{{MC4>sr devmgr ethernet query
80 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
81 -MC4>sr devmgr ethernet show devices
82 -
83 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
84 -| Adapter | Hostname | IP Address | IP-ID | ID |
85 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
86 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 |
87 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
88 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] |
89 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
90 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] |
91 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
92 -
93 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
94 -Claimed ethernet device: CEN-GWEXER-9E6ADA
95 -MC4>Update request from IP-ID-30 in Program 01
96 -MC4>sr discover zum false
97 -Starting Zum Discovery without gateway claiming
98 -MC4>Performing Discovery on 1 Gateways.
70 +{{{MC4>sr discover zum true
71 +Starting Zum Discovery with gateway claiming
72 +MC4>Found 1 Gateways to check.
73 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
74 +Update request from IP-ID-30 in Program 01
75 +Claimed 1 Gateways. Waiting for queries to finish.
76 +Performing Discovery on 1 Gateways.
99 99  Evaluating 3 Devices on Gateway 30
100 100  Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30
101 101  Dev: ZUM-NETBRIDGE addrssing to RF ID: 03
... ... @@ -106,7 +106,6 @@
106 106  Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30
107 107  Dev: ZUM-NETBRIDGE addrssing to RF ID: 05
108 108  Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05
109 -Querying cresnet
110 110  Discovering Zum Loads on 1 Gateways.
111 111  Discovering Zum Loads on 3 Devices.
112 112  NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0
... ... @@ -175,17 +175,31 @@
175 175  New Loads: 6
176 176  Modified Loads: 0
177 177  Removed Loads: 0
178 -Zum Discovery Finished}}}
155 +Zum Discovery Finished
156 +}}}
179 179  
180 -=== Claim All Example ===
158 +=== Example for Option 2: ===
181 181  
182 -{{{MC4>sr discover zum true
183 -Starting Zum Discovery with gateway claiming
184 -MC4>Found 1 Gateways to check.
185 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
186 -Update request from IP-ID-30 in Program 01
187 -Claimed 1 Gateways. Waiting for queries to finish.
188 -Performing Discovery on 1 Gateways.
160 +{{{MC4>sr devmgr ethernet query
161 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
162 +MC4>sr devmgr ethernet show devices
163 +
164 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
165 +| Adapter | Hostname | IP Address | IP-ID | ID |
166 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
167 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 |
168 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
169 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] |
170 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
171 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] |
172 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
173 +
174 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
175 +Claimed ethernet device: CEN-GWEXER-9E6ADA
176 +MC4>Update request from IP-ID-30 in Program 01
177 +MC4>sr discover zum false
178 +Starting Zum Discovery without gateway claiming
179 +MC4>Performing Discovery on 1 Gateways.
189 189  Evaluating 3 Devices on Gateway 30
190 190  Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30
191 191  Dev: ZUM-NETBRIDGE addrssing to RF ID: 03
... ... @@ -196,6 +196,7 @@
196 196  Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30
197 197  Dev: ZUM-NETBRIDGE addrssing to RF ID: 05
198 198  Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05
190 +Querying cresnet
199 199  Discovering Zum Loads on 1 Gateways.
200 200  Discovering Zum Loads on 3 Devices.
201 201  NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0
... ... @@ -265,5 +265,5 @@
265 265  Modified Loads: 0
266 266  Removed Loads: 0
267 267  Zum Discovery Finished
268 -}}}
260 + }}}
269 269  )))