Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
on 2022/09/22 22:11
Change comment:
There is no comment for this version
To version 2.1
edited by Alexander Mott
on 2022/09/22 21:44
on 2022/09/22 21:44
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Content
-
... ... @@ -1,6 +1,6 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -10,92 +10,69 @@ 10 10 11 11 (% class="row" %) 12 12 ((( 13 -If Zūm Wiredor Wirelessdevices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.13 +If Zūm Net devices have been configured using Crestron's Zūm App 14 14 15 - Thereare certain pre-requisites and limitationswhen building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 16 16 17 -= Zūm Wired Discovery = 18 - 19 19 Lorem 20 20 21 -= Zūm Wireless Discovery=19 += Zūm Wireless = 22 22 21 + 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 23 *Disconnect from the gateway before discovery as they cannot support multiple connections* 24 24 *Plug loads do not appear in the UI* 25 25 26 -== Notesand Limitations ==26 +== **Pre-Requisites:** == 27 27 28 -* SHOWRUNNER™ version 2.190 or newer required 29 -* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command, 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 30 30 31 -== Pre-Requisites==32 +=== **Caution:** === 32 32 33 -* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 34 -* SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway 35 -* NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored. 36 -))) 34 +* ShowRunner has 2 discovery approaches. 35 +** Option 1: Claim All RF Gateways - ShowRunner will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. DO NOT use this method if there are gateways used by different ShowRunner or other Crestron systems on the same local network. 36 +** Option 2: Manual RF Gateway Assignment - ShowRunner can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 37 37 38 -(% class="box warningmessage" id="HCaution:" %) 39 -((( 40 -**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 38 +== Option 1: Claim All Gateways: == 41 41 42 -1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 43 -1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 44 -))) 40 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 45 45 46 -(% class="row" %) 47 -((( 48 -== Manual RF Gateway Assignment == 42 +* Connect to the processor's console with Toolbox or your favorite SSH client. 43 +* Type "//sr discover zum true//" and press enter. 44 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 45 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 46 +* Type "//progreset//" and press enter to restart ShowRunner 47 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 48 +* Once completed ShowRunner is now ready for full Zum control 49 49 50 - Usethis methodifyou have multipleSHOWRUNNER™instances onthesame network or have gatewaysused by otherCrestronsystems.50 +== Option 2: Manual RF Gateway Claiming: == 51 51 52 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 53 + 52 52 * Connect to the processor's console with Toolbox or your favorite SSH client. 53 53 * Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 54 54 * Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 55 -* For each gateway that you'd like this instance of S HOWRUNNER™to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". SHOWRUNNER™will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™,proceed to the next step.57 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 56 56 * Type "//sr discover zum false//" and press enter. 57 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 58 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. HOWRUNNER™must be restarted to complete the acquire process.59 -* Type "//progreset//" and press enter to restart S HOWRUNNER™60 -* Once S HOWRUNNER™has finished restarting type "//sr discover zum false//" and press enter.HOWRUNNER™will be able to acquire the loads attached to the Zūm rooms at this point.61 -* Once completed S HOWRUNNER™is now ready for full Zūm control59 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 60 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 61 +* Type "//progreset//" and press enter to restart ShowRunner 62 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 63 +* Once completed ShowRunner is now ready for full Zum control 62 62 63 -== Claim All RF Gateways == 64 - 65 -Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 66 - 67 -* Connect to the processor's console with Toolbox or your favorite SSH client. 68 -* Type "//sr discover zum true//" and press enter. 69 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 70 -* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 71 -* Type "//progreset//" and press enter to restart SHOWRUNNER™ 72 -* Once SHOWRUNNER™ has finished restarting type "//sr discover zum false//" and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 73 -* Once completed SHOWRUNNER™ is now ready for full Zūm control 74 - 75 75 == Examples == 76 76 77 -=== ManualExample ===67 +=== Example for Option 1: === 78 78 79 -{{{MC4>sr devmgr ethernet query 80 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 81 -MC4>sr devmgr ethernet show devices 82 - 83 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 84 -| Adapter | Hostname | IP Address | IP-ID | ID | 85 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 86 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 87 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 88 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 89 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 90 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 91 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 92 - 93 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 94 -Claimed ethernet device: CEN-GWEXER-9E6ADA 95 -MC4>Update request from IP-ID-30 in Program 01 96 -MC4>sr discover zum false 97 -Starting Zum Discovery without gateway claiming 98 -MC4>Performing Discovery on 1 Gateways. 69 +{{{MC4>sr discover zum true 70 +Starting Zum Discovery with gateway claiming 71 +MC4>Found 1 Gateways to check. 72 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 73 +Update request from IP-ID-30 in Program 01 74 +Claimed 1 Gateways. Waiting for queries to finish. 75 +Performing Discovery on 1 Gateways. 99 99 Evaluating 3 Devices on Gateway 30 100 100 Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 101 101 Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 ... ... @@ -106,7 +106,6 @@ 106 106 Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 107 107 Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 108 108 Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 109 -Querying cresnet 110 110 Discovering Zum Loads on 1 Gateways. 111 111 Discovering Zum Loads on 3 Devices. 112 112 NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 ... ... @@ -175,17 +175,31 @@ 175 175 New Loads: 6 176 176 Modified Loads: 0 177 177 Removed Loads: 0 178 -Zum Discovery Finished}}} 154 +Zum Discovery Finished 155 +}}} 179 179 180 -=== Claim AllExample ===157 +=== Example for Option 2: === 181 181 182 -{{{MC4>sr discover zum true 183 -Starting Zum Discovery with gateway claiming 184 -MC4>Found 1 Gateways to check. 185 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 186 -Update request from IP-ID-30 in Program 01 187 -Claimed 1 Gateways. Waiting for queries to finish. 188 -Performing Discovery on 1 Gateways. 159 +{{{MC4>sr devmgr ethernet query 160 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 161 +MC4>sr devmgr ethernet show devices 162 + 163 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 164 +| Adapter | Hostname | IP Address | IP-ID | ID | 165 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 166 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 | 167 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 168 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] | 169 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 170 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] | 171 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+ 172 + 173 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 174 +Claimed ethernet device: CEN-GWEXER-9E6ADA 175 +MC4>Update request from IP-ID-30 in Program 01 176 +MC4>sr discover zum false 177 +Starting Zum Discovery without gateway claiming 178 +MC4>Performing Discovery on 1 Gateways. 189 189 Evaluating 3 Devices on Gateway 30 190 190 Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30 191 191 Dev: ZUM-NETBRIDGE addrssing to RF ID: 03 ... ... @@ -196,6 +196,7 @@ 196 196 Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30 197 197 Dev: ZUM-NETBRIDGE addrssing to RF ID: 05 198 198 Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05 189 +Querying cresnet 199 199 Discovering Zum Loads on 1 Gateways. 200 200 Discovering Zum Loads on 3 Devices. 201 201 NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0 ... ... @@ -265,5 +265,5 @@ 265 265 Modified Loads: 0 266 266 Removed Loads: 0 267 267 Zum Discovery Finished 268 -}}} 259 + }}} 269 269 )))