Changes for page Zūm Discovery

Last modified by Alexander Mott on 2025/04/03 17:35

From version 5.1
edited by Alexander Mott
on 2022/09/22 21:55
Change comment: There is no comment for this version
To version 5.2
edited by Alexander Mott
on 2022/09/22 22:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Autodiscovery
1 +Zūm Discovery
Content
... ... @@ -1,6 +1,6 @@
1 1  (% class="box warningmessage" %)
2 2  (((
3 -This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
4 4  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
5 5  )))
6 6  
... ... @@ -10,20 +10,26 @@
10 10  
11 11  (% class="row" %)
12 12  (((
13 -If Zūm Net devices have been configured using Crestron's Zūm App
13 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Autodiscovery feature that is built into SHOWRUNNER™.
14 14  
15 -= m Wired =
15 +There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
16 16  
17 += Zūm Wired Discovery =
18 +
17 17  Lorem
18 18  
19 -= Zūm Wireless =
21 += Zūm Wireless Discovery =
20 20  
21 -As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
22 22  *Disconnect from the gateway before discovery as they cannot support multiple connections*
23 23  *Plug loads do not appear in the UI*
24 24  
25 -== Pre-Requisites: ==
26 +== Notes and Limitations ==
26 26  
28 +* SHOWRUNNER™ version 2.190 or newer required
29 +* Disconnect from any RF gateways you are connected to prior to running the autodiscovery command,
30 +
31 +== Pre-Requisites ==
32 +
27 27  * Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
28 28  * SHOWRUNNER™ installed and running on a 3-series processor on the same network as the gateway
29 29  * NETBRIDGES do not need to have addresses assigned. SHOWRUNNER™ will automatically address them. If devices all already addressed then their addresses will be honored.
... ... @@ -39,7 +39,7 @@
39 39  
40 40  (% class="row" %)
41 41  (((
42 -== Manual RF Gateway Claiming ==
48 +== Manual RF Gateway Assignment ==
43 43  
44 44  Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems.
45 45  
... ... @@ -68,7 +68,7 @@
68 68  
69 69  == Examples ==
70 70  
71 -=== Claim Selectively (Manual) Example ===
77 +=== Manual Example ===
72 72  
73 73  {{{MC4>sr devmgr ethernet query
74 74  Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess