Changes for page Zūm Discovery

Last modified by Craig Lewis on 2025/09/25 20:36

From version 43.1
edited by Craig Lewis
on 2025/09/25 20:36
Change comment: There is no comment for this version
To version 2.1
edited by Alexander Mott
on 2022/09/22 21:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Discovery
1 +Zūm Autodiscovery
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.WebHome
1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.craig\.lewis@chiefintegrations\.com
1 +XWiki.alexander\.mott@chiefintegrations\.com
Content
... ... @@ -1,14 +9,6 @@
1 -(% class="box errormessage" %)
2 -(((
3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself.
4 -
5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database.
6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions.
7 -)))
8 -
9 9  (% class="box warningmessage" %)
10 10  (((
11 -This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].
3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].
12 12  For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]].
13 13  )))
14 14  
... ... @@ -16,232 +16,71 @@
16 16  {{toc/}}
17 17  {{/box}}
18 18  
19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™.
20 -
21 -There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.
22 -
23 -= Discovery Filter (ShowRunnerCLC™ 3.062 or newer) =
24 -
25 -Discovered ethernet devices may be filtered using either a hostname or IP Address filter.  The filter is configured from the command line interface.
26 -
27 -##+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+
28 -~| Command | Help |
29 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|
30 -~| SR discover clear filter | Remove Discovery Filter |
31 -~| SR discover filter | Show Discovery Filter |
32 -~| SR discover filter (X:S) | Set Discovery Filter |
33 -~| - | (X):S:Filter String |
34 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|##
35 -
36 -=== Hostname Filter ===
37 -
38 -The Hostname filter uses a regular expression to filter discovered ZUMNET GATEWAYs or JBOXs.  Multiple expressions can be applied by using a comma to separate the expressions.
39 -
40 -Command Syntax: ##"Type='Hostname' Settings='Expr1[,Expr2]'"##
41 -
42 -Examples:
43 -
44 -1. Only include hostnames that start with ZUMNET-06:
45 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-06'"
46 -1. Include hostnames that start with ZUMNET-FL01 or contain FL03:
47 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-FL01,FL03'"
48 -
49 -=== IP Address Filter ===
50 -
51 -The IP Address filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP Addresses or IP Address ranges.  Multiple addresses and ranges can be used.
52 -
53 -Command Syntax: ##"Type='IPAddress' Settings='Address[,AddressStart-AddressEnd]'"##
54 -
55 -Examples:
56 -
57 -1. Only include a device with an address of 192.168.0.10 or 192.168.0.50:
58 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.10,192.168.0.50'"
59 -1. Include addresses between 192.168.0.11 and 192.168.0.50 and 192.168.0.200 and 192.168.0.240:
60 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.11-192.168.0.50,192.168.0.200-192.168.0.240'"
61 -
62 -=== IP-ID Filter (Added in SR v3.067) ===
63 -
64 -The IP-ID filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP-IDs or IP-ID ranges.  Multiple IDs and ranges can be used.
65 -
66 -Command Syntax: ##"Type='IPID' Settings='IPID[,IPIDStart-IPIDEnd]'"##
67 -
68 -Examples:
69 -
70 -1. Only include a device with an IP-ID of 10 or 5A:
71 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPID' Settings='10,5A'"
72 -1. Include addresses between 11 and 4F and A0 and BF:
73 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPID' Settings='11-4F,A0-BF'"
74 -
75 -= Zūm Wired Discovery =
76 -
77 -== Notes and Limitations ==
78 -
79 -(% class="box warningmessage" %)
11 +(% class="row" %)
80 80  (((
81 -* ShowRunnerCLC™ version 3.014 or newer required
82 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081)
83 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are online prior to running the discovery commands
84 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release)
85 -* ZUMLINK-IOs will not be discovered (Expected to be discoverable in future ShowRunnerCLC™ release)
86 -* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer will discover keypads and set as remote type)
87 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually
88 -* ZUMNET-JBOX-DALI will be created with only 1 broadcast load index 17. If ZUMNET is being setup as a LEGACY controller, the config will need to be updated to reflect the model as ZUMNET-JBOX-DALI-LEGACY.
89 -)))
13 +If Zūm Net devices have been configured using Crestron's Zūm App
90 90  
91 -== Steps ==
15 += Zūm Wired =
92 92  
93 -1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary
94 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices.
95 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 
96 -1*. Connect to the first ZUMNET-JBOX in Toolbox
97 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
98 -1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production
99 -1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
100 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated
101 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX
102 -1*. Repeat the above steps for all ZUMNET-JBOXs
103 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step
104 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App
105 -1*. Commission room through the app
106 -1**. configure keypad logic
107 -1**. configure occupancy sensor settings
108 -1**. calibrate photocell(s)
109 -1*. Set hostnames for the ZUMNETs.
110 -1**. Zūm discovery will bring in hostnames.
111 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX
112 -1*. If firmware was out-of-date, then this step should have already been completed
113 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs
114 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 
115 -1*. If firmware was out-of-date, then this step should have already been completed
116 -1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production
117 -1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses
118 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID
119 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery
120 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program
121 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode
122 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices
123 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox
124 -1. If trying to Auto Discover on a job with multiple processors or you are returning to a job where new ZUMNET-JBOXs have been added and you only wish to Auto Discover those new devices, ShowRunnerCLC™ 3.062 and newer allow [[filtering based on hostname or IP address>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome||anchor="HDiscoveryFilter28ShowRunnerCLC21223.062ornewer29"]] in order to limit the devices that are brought into the ShowRunnerCLC™ configuration
125 -1. Run the command: ##sr discover zumnet true true## to add ZUMNET-JBOXs, connected ZUMLINK devices, and some Cresnet devices (such as Cameo keypads) to the configuration. (Note
126 -1*. This command will update the ShowRunnerCLC™ configuration with: 
127 -1**. One area per claimed ZUMNET-JBOX based on the Room Name set in the app
128 -1**. One ZUMNET-BRIDGE load controller per claimed ZUMNET-JBOX to allow the Zūm Room to communicate its current status (scene, occupancy, etc.) to ShowRunnerCLC™
129 -1**. One entry for each ZUMLINK-KP, ZUMLINK-JBOX, and ZUMLINK occupancy sensor connected to each ZUMNET-JBOX
130 -1***. All devices and loads will be auto-labeled based on their connection information, //not// the names they are given in the Zūm App
131 -1***. Keypads will be brought in as "Remote" type and only follow the logic as defined in the Zūm App, allowing for scheduled enabling/disabling of keypads without adding any additional button functions from ShowRunnerCLC™
132 -1***. Occupancy sensors will be brought in with "Use Hardware Logic" and only follow the logic as defined in the Zūm App
133 -1*. Optionally, run ##sr discover zumnet false true## to only add new ZUMLINK devices to the configuration. **Note that previously added ZUMLINK devices will be added again if their CID has been changed**
134 -1*. Run ##sr discover zumnet true false## to add ZUMNET-JBOXs without bringing in any devices. **Note that if a ZUMNET-JBOX already has an entry in its IP Table, ShowRunnerCLC™ will not claim it.** The ZUMNET-JBOX's IP Table must be cleared in order for it to be claimed by the ShowRunnerCLC™ program
135 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly.
136 -1. If new Zūm Link hardware has been added, it is not necessary to do a full Auto Discovery to bring the new devices into ShowRunnerCLC™; instead you can just run ##sr discover zumnet false true## to bring in the new Zūm Link devices without claiming any new Zūm Net devices
17 +Lorem
137 137  
138 -= Zūm Wireless Discovery =
19 += Zūm Wireless =
139 139  
140 -== Notes and Limitations ==
141 141  
142 -(% class="box warningmessage" %)
143 -(((
144 -* **Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER**
145 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired
146 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##**
147 -* ZUM-NETBRIDGES must already be acquired to their respective gateway
148 -* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices
149 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command
150 -* Plug loads will not appear in the ShowRunnerCLC™ UI
151 -)))
22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads.
23 +*Disconnect from the gateway before discovery as they cannot support multiple connections*
24 +*Plug loads do not appear in the UI*
152 152  
153 -(% class="box infomessage" id="HCaution:" %)
154 -(((
155 -**Note:** ShowRunnerCLC™ has two different approaches for Zūm Wireless Discovery
26 +== **Pre-Requisites:** ==
156 156  
157 -1. **Manual RF Gateway Assignment** - ShowRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
158 -1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.
159 -)))
28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY)
29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway
30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored.
160 160  
161 -(% class="box errormessage" id="HCaution:" %)
162 -(((
163 -**Note:** Due to what is believed to be an SSL issue, ShowRunnerCLC™ will sometimes fail to acquire Zūm Wireless gateways with the ##sr discover zummesh true## or ##sr ethernet device claim [Hostname]## commands.
32 +=== **Caution:** ===
164 164  
165 -To work around this issue, Zūm Wireless gateways need to be added to the "IpDevices" section of the SrConfig.json and then have their IP Tables manually updated using the ##addm [IP-ID] [Processor IP]## command. Once this has been done, the ##sr discover zummesh false## commands can be run as normal.
34 +* ShowRunner has 2 discovery approaches.
35 +** Option 1: Claim All RF Gateways - ShowRunner will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. DO NOT use this method if there are gateways used by different ShowRunner or other Crestron systems on the same local network.
36 +** Option 2: Manual RF Gateway Assignment - ShowRunner can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.
166 166  
167 -Below is an example "IpDevices" section of a config with three gateways defined. Serial numbers are optional and can be deleted if not known. **Note:**  the "IpId" here is decimal, whereas the actual IP-ID that is assigned from Text Console is in hexadecimal. You will need to convert between the two: e.g. decimal "48" corresponds to hexadecimal "30", decimal "74" would correspond to hexadecimal "4A", etc.
38 +== Option 1: Claim All Gateways: ==
168 168  
169 -{{{ "Eiscs": [],
170 - "IpDevices": [
171 - {
172 - "Model": "CEN-GWEXER",
173 - "Name": "GW-1-1",
174 - "SerialNumber": "2402NEJ03956",
175 - "IpId": 48
176 - },
177 - {
178 - "Model": "CEN-GWEXER",
179 - "Name": "GW-1-2",
180 - "SerialNumber": "2402NEJ03862",
181 - "IpId": 49
182 - },
183 - {
184 - "Model": "CEN-GWEXER",
185 - "Name": "GW-2-1",
186 - "SerialNumber": "2402NEJ03887",
187 - "IpId": 50
188 - }
189 - ],
190 - "Keyswitches": [],}}}
191 -)))
40 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner.
192 192  
193 -== Manual RF Gateway Assignment Instructions ==
194 -
195 -Use this method if you have multiple ShowRunnerCLC™ instances on the same network or have gateways used by other Crestron systems.
196 -
197 197  * Connect to the processor's console with Toolbox or your favorite SSH client.
198 -* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways.
199 -* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices.
200 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step.
201 -* Type ##sr discover zummesh false## and press enter.
202 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
203 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.
204 -* Type ##progreset## and press enter to restart ShowRunnerCLC™
205 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.
206 -* Once completed SHOWRUNNER™ is now ready for full Zūm control
43 +* Type "//sr discover zum true//" and press enter.
44 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
45 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
46 +* Type "//progreset//" and press enter to restart ShowRunner
47 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
48 +* Once completed ShowRunner is now ready for full Zum control
207 207  
208 -== Claim All RF Gateways Instructions ==
50 +== Option 2: Manual RF Gateway Claiming: ==
209 209  
210 -Use this method when you have a single ShowRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™.
52 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems.
211 211  
212 212  * Connect to the processor's console with Toolbox or your favorite SSH client.
213 -* Type ##sr discover zummesh true## and press enter. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step.
214 -* Type ##sr discover zummesh false## and press enter.
215 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
216 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process.
217 -* Type ##progreset## and press enter to restart ShowRunnerCLC™
218 -* Once ShowRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.
219 -* Once completed ShowRunnerCLC™ is now ready for full Zūm control
55 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways.
56 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices.
57 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step.
58 +* Type "//sr discover zum false//" and press enter.
59 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes.
60 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process.
61 +* Type "//progreset//" and press enter to restart ShowRunner
62 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point.
63 +* Once completed ShowRunner is now ready for full Zum control
220 220  
221 221  == Examples ==
222 222  
223 -=== Manual Example ===
67 +=== Example for Option 1: ===
224 224  
225 -{{{MC4>sr devmgr ethernet query
226 -Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
227 -MC4>sr devmgr ethernet show devices
228 -
229 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
230 -| Adapter | Hostname | IP Address | IP-ID | ID |
231 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
232 -| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 |
233 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
234 -| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] |
235 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
236 -| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] |
237 -+--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
238 -
239 -MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
240 -Claimed ethernet device: CEN-GWEXER-9E6ADA
241 -MC4>Update request from IP-ID-30 in Program 01
242 -MC4>sr discover zummesh false
243 -Starting Zum Discovery without gateway claiming
244 -MC4>Performing Discovery on 1 Gateways.
69 +{{{MC4>sr discover zum true
70 +Starting Zum Discovery with gateway claiming
71 +MC4>Found 1 Gateways to check.
72 +Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
73 +Update request from IP-ID-30 in Program 01
74 +Claimed 1 Gateways. Waiting for queries to finish.
75 +Performing Discovery on 1 Gateways.
245 245  Evaluating 3 Devices on Gateway 30
246 246  Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30
247 247  Dev: ZUM-NETBRIDGE addrssing to RF ID: 03
... ... @@ -252,7 +252,6 @@
252 252  Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30
253 253  Dev: ZUM-NETBRIDGE addrssing to RF ID: 05
254 254  Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05
255 -Querying cresnet
256 256  Discovering Zum Loads on 1 Gateways.
257 257  Discovering Zum Loads on 3 Devices.
258 258  NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0
... ... @@ -272,7 +272,7 @@
272 272  MC4>progreset
273 273  ...
274 274  CI ShowRunner startup completed successfully in 8072ms
275 -MC4>sr discover zummesh false
105 +MC4>sr discover zum false
276 276  Starting Zum Discovery without gateway claiming
277 277  MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable)
278 278  Performing Discovery on 1 Gateways.
... ... @@ -321,17 +321,31 @@
321 321  New Loads: 6
322 322  Modified Loads: 0
323 323  Removed Loads: 0
324 -Zum Discovery Finished}}}
154 +Zum Discovery Finished
155 +}}}
325 325  
326 -=== Claim All Example ===
157 +=== Example for Option 2: ===
327 327  
328 -{{{MC4>sr discover zummesh true
329 -Starting Zum Discovery with gateway claiming
330 -MC4>Found 1 Gateways to check.
331 -Claimed Gateway SN: 1720JBH04269 at IP-ID: 30
332 -Update request from IP-ID-30 in Program 01
333 -Claimed 1 Gateways. Waiting for queries to finish.
334 -Performing Discovery on 1 Gateways.
159 +{{{MC4>sr devmgr ethernet query
160 +Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess
161 +MC4>sr devmgr ethernet show devices
162 +
163 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
164 +| Adapter | Hostname | IP Address | IP-ID | ID |
165 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
166 +| EthernetLANAdapter | CI-SJC-CEN-CI3-1-COM3 | 10.44.5.20 | 00 | CEN-CI3-1-C3COM-3 [v1.1620.00000, #008436E2] type:1 |
167 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
168 +| EthernetLANAdapter | SB-DIN-CENCN-2 | 10.44.5.81 | 00 | DIN-CENCN-2-POE [v1.3544.00006, #8AB25AA3] |
169 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
170 +| EthernetLANAdapter | CEN-GWEXER-9E6ADA | 10.44.5.120 | 00 | CEN-GWEXER [v1.4230.00015, #848210AD] |
171 ++--------------------+-------------------------------+-------------+-------+----------------------------------------------------------------------------------+
172 +
173 +MC4>sr ethernet device claim CEN-GWEXER-9E6ADA
174 +Claimed ethernet device: CEN-GWEXER-9E6ADA
175 +MC4>Update request from IP-ID-30 in Program 01
176 +MC4>sr discover zum false
177 +Starting Zum Discovery without gateway claiming
178 +MC4>Performing Discovery on 1 Gateways.
335 335  Evaluating 3 Devices on Gateway 30
336 336  Claiming ZUM-NETBRIDGE SN: 1726NEJ01096 from IP-ID: 30
337 337  Dev: ZUM-NETBRIDGE addrssing to RF ID: 03
... ... @@ -342,6 +342,7 @@
342 342  Claiming ZUM-NETBRIDGE SN: 1914NEJ03098 from IP-ID: 30
343 343  Dev: ZUM-NETBRIDGE addrssing to RF ID: 05
344 344  Setting up RF Device 'ZUM-NETBRIDGE' on Gateway 30 at RF-ID 05
189 +Querying cresnet
345 345  Discovering Zum Loads on 1 Gateways.
346 346  Discovering Zum Loads on 3 Devices.
347 347  NETBIRDGE: NewLoads: 0 ModifiedLoads: 0 RemovedLoads: 0
... ... @@ -361,7 +361,7 @@
361 361  MC4>progreset
362 362  ...
363 363  CI ShowRunner startup completed successfully in 8072ms
364 -MC4>sr discover zummesh false
209 +MC4>sr discover zum false
365 365  Starting Zum Discovery without gateway claiming
366 366  MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable)
367 367  Performing Discovery on 1 Gateways.
... ... @@ -411,4 +411,5 @@
411 411  Modified Loads: 0
412 412  Removed Loads: 0
413 413  Zum Discovery Finished
414 -}}}
259 + }}}
260 +)))