Changes for page Zūm Discovery
Last modified by Craig Lewis on 2025/09/25 20:36
From version 40.1
edited by Alexander Mott
on 2025/04/03 17:35
on 2025/04/03 17:35
Change comment:
There is no comment for this version
To version 42.1
edited by Alexander Mott
on 2025/08/22 17:15
on 2025/08/22 17:15
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,6 @@ 1 1 (% class="box errormessage" %) 2 2 ((( 3 - ūūūūūū**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself.3 +**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 4 5 5 **WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 6 ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. ... ... @@ -140,6 +140,7 @@ 140 140 141 141 (% class="box warningmessage" %) 142 142 ((( 143 +* **Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER** 143 143 * Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 144 144 ** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 145 145 * ZUM-NETBRIDGES must already be acquired to their respective gateway ... ... @@ -146,7 +146,6 @@ 146 146 * ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 147 147 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 148 148 * Plug loads will not appear in the ShowRunnerCLC™ UI 149 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 150 150 ))) 151 151 152 152 (% class="box infomessage" id="HCaution:" %)