Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 4.1
edited by Alexander Mott
on 2022/09/22 21:50
on 2022/09/22 21:50
Change comment:
There is no comment for this version
To version 19.1
edited by Scott Kohlmann
on 2023/04/21 13:58
on 2023/04/21 13:58
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Autodiscovery1 +Zūm Discovery - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. alexander\.mott@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,6 +1,13 @@ 1 +(% class="box errormessage" %) 2 +((( 3 +WARNING: Cresnet Discovery is not currently working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. 4 + 5 +Downgrade ShowRunnerCLC™ to v3.018 in order to auto-discover hardware. ShowRunnerCLC™ can be subsequently upgraded once discovery is complete. 6 +))) 7 + 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -This article is about automatically building a S HOWRUNNER™ configuration using the ZūmAutodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]].10 +This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 4 4 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 5 5 ))) 6 6 ... ... @@ -8,70 +8,111 @@ 8 8 {{toc/}} 9 9 {{/box}} 10 10 11 -(% class="row" %) 12 -((( 13 -If Zūm Net devices have been configured using Crestron's Zūm App 18 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 14 14 15 - =ZūmWired=20 +There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 16 16 17 - Lorem22 += Zūm Wired Discovery = 18 18 19 -= ZūmWireless=24 +== Notes and Limitations == 20 20 26 +(% class="box warningmessage" %) 27 +((( 28 +* ShowRunnerCLC™ version 3.014 or newer required 29 +* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 30 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 31 +* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 32 +* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 33 +))) 21 21 22 -As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 -*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 -*Plug loads do not appear in the UI* 35 +== Steps == 25 25 26 -== Pre-Requisites: == 37 +1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 38 +1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 39 +1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 40 +1*. Connect to the first ZUMNET-JBOX in Toolbox 41 +1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 42 +1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 43 +1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 44 +1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 45 +1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 46 +1*. Repeat the above steps for all ZUMNET-JBOXs 47 +1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 48 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 49 +1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 50 +1*. If firmware was out-of-date, then this step should have already been completed 51 +1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 52 +1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 53 +1*. If firmware was out-of-date, then this step should have already been completed 54 +1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 55 +1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 56 +1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 57 +1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 58 +1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 59 +1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 60 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 61 +1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 62 +1. Run the command: ##sr discover zumnet true false## 63 +1*. This command tells ShowRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 64 +1. Run the command: ##sr discover zumnet true true## 65 +1*. This command tells ShowRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 66 +1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 67 +1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 68 +1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 27 27 28 -* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 -* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 -* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 70 += Zūm Wireless Discovery = 71 + 72 +== Notes and Limitations == 73 + 74 +(% class="box warningmessage" %) 75 +((( 76 +* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 77 +** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 78 +* ZUM-NETBRIDGES must already be acquired to their respective gateway 79 +* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 80 +* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 81 +* Plug loads will not appear in the ShowRunnerCLC™ UI 31 31 ))) 32 32 33 -(% class="box warningmessage" id="HCaution:" %)84 +(% class="box infomessage" id="HCaution:" %) 34 34 ((( 35 -**Note:** S HOWRUNNER™ has two different approaches for Zūm WirelessAutodiscovery86 +**Note:** ShowRunnerCLC™ has two different approaches for Zūm Wireless Discovery 36 36 37 -1. **Manual RF Gateway Assignment** - S HOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.38 -1. **Claim All RF Gateways** - S HOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network.88 +1. **Manual RF Gateway Assignment** - ShowRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 89 +1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network. 39 39 ))) 40 40 41 -(% class="row" %) 42 -((( 43 -== Option 1: Manual RF Gateway Claiming: == 92 +== Manual RF Gateway Assignment Instructions == 44 44 45 -Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 94 +Use this method if you have multiple ShowRunnerCLC™ instances on the same network or have gateways used by other Crestron systems. 46 46 47 47 * Connect to the processor's console with Toolbox or your favorite SSH client. 48 -* Type "//sr devmgr ethernet query//"and press enter. This queries the local network for RF Gateways.49 -* Type "//sr devmgr ethernet show devices//"and press enter. This displays all found Crestron ethernet devices.50 -* For each gateway that you'd like this instance of S howRunnerto use, use the hostname from the table of found ethernet devices."//sr ethernet device claim CEN-GWEXER-9E6ADA//".51 -* Type "//sr discover zum false//"and press enter.52 -* Status messages and the results will be displayed on the console. 53 -* When the discovery is finished type "//sr save//"and press enter to save the updated config.54 -* Type "//progreset//"and press enter to restart ShowRunner55 -* Once S howRunnerhas finished restarting type"//sr discover zum false//"and press enter.um rooms at this point.56 -* Once completed S howRunneris now ready for full Zum control97 +* Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 98 +* Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 99 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step. 100 +* Type ##sr discover zummesh false## and press enter. 101 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 102 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 103 +* Type ##progreset## and press enter to restart ShowRunnerCLC™ 104 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 105 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 57 57 58 -== Option 2:Claim All Gateways:==107 +== Claim All RF Gateways Instructions == 59 59 60 -Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 109 +Use this method when you have a single ShowRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™. 61 61 62 62 * Connect to the processor's console with Toolbox or your favorite SSH client. 63 -* Type "//sr discover zum true//"and press enter.64 -* Status messages and the results will be displayed on the console. 65 -* When the discovery is finished type "//sr save//"and press enter to save the updated config.66 -* Type "//progreset//"and press enter to restart ShowRunner67 -* Once ShowRunner has finished restarting type "//sr discover zum false//"and press enter.um rooms at this point.68 -* Once completed ShowRunner is now ready for full Z um control112 +* Type ##sr discover zummesh true## and press enter. 113 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 114 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 115 +* Type ##progreset## and press enter to restart ShowRunnerCLC™ 116 +* Once ShowRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 117 +* Once completed ShowRunnerCLC™ is now ready for full Zūm control 69 69 70 70 == Examples == 71 71 121 +=== Manual Example === 72 72 73 -=== Example for Option 1: === 74 - 75 75 {{{MC4>sr devmgr ethernet query 76 76 Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 77 77 MC4>sr devmgr ethernet show devices ... ... @@ -89,7 +89,7 @@ 89 89 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 90 90 Claimed ethernet device: CEN-GWEXER-9E6ADA 91 91 MC4>Update request from IP-ID-30 in Program 01 92 -MC4>sr discover zum false 140 +MC4>sr discover zummesh false 93 93 Starting Zum Discovery without gateway claiming 94 94 MC4>Performing Discovery on 1 Gateways. 95 95 Evaluating 3 Devices on Gateway 30 ... ... @@ -122,7 +122,7 @@ 122 122 MC4>progreset 123 123 ... 124 124 CI ShowRunner startup completed successfully in 8072ms 125 -MC4>sr discover zum false 173 +MC4>sr discover zummesh false 126 126 Starting Zum Discovery without gateway claiming 127 127 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 128 128 Performing Discovery on 1 Gateways. ... ... @@ -173,9 +173,9 @@ 173 173 Removed Loads: 0 174 174 Zum Discovery Finished}}} 175 175 176 -=== Example for Option 2:===224 +=== Claim All Example === 177 177 178 -{{{MC4>sr discover zum true 226 +{{{MC4>sr discover zummesh true 179 179 Starting Zum Discovery with gateway claiming 180 180 MC4>Found 1 Gateways to check. 181 181 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -211,7 +211,7 @@ 211 211 MC4>progreset 212 212 ... 213 213 CI ShowRunner startup completed successfully in 8072ms 214 -MC4>sr discover zum false 262 +MC4>sr discover zummesh false 215 215 Starting Zum Discovery without gateway claiming 216 216 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 217 217 Performing Discovery on 1 Gateways. ... ... @@ -262,4 +262,3 @@ 262 262 Removed Loads: 0 263 263 Zum Discovery Finished 264 264 }}} 265 -)))