Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 39.1
edited by Alexander Mott
on 2025/04/03 16:11
on 2025/04/03 16:11
Change comment:
There is no comment for this version
To version 4.1
edited by Alexander Mott
on 2022/09/22 21:50
on 2022/09/22 21:50
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Discovery1 +Zūm Autodiscovery - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -ūūūūūū**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the ZūmDiscovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Autodiscovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,179 +16,70 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a ShowRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™. 11 +(% class="row" %) 12 +((( 13 +If Zūm Net devices have been configured using Crestron's Zūm App 20 20 21 - Thereare certain pre-requisites and limitationswhen building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustmentsto the final configuration, such as changing keypad types and moving loads between areas.15 += Zūm Wired = 22 22 23 - = Discovery Filter (ShowRunnerCLC™ 3.062ornewer) =17 +Lorem 24 24 25 - Discoveredethernet devicesmaybe filtered usingeither a hostname or IP Addressfilter. The filter is configured from the command line interface.19 += Zūm Wireless = 26 26 27 -##+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 28 -~| Command | Help | 29 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-| 30 -~| SR discover clear filter | Remove Discovery Filter | 31 -~| SR discover filter | Show Discovery Filter | 32 -~| SR discover filter (X:S) | Set Discovery Filter | 33 -~| - | (X):S:Filter String | 34 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|## 35 35 36 -=== Hostname Filter === 22 +As of version 2.190 ShowRunner can discover RF Gateways and attached Zum NETBRIDGES. ShowRunner will find all devices, set them up, create areas and loads. 23 +*Disconnect from the gateway before discovery as they cannot support multiple connections* 24 +*Plug loads do not appear in the UI* 37 37 38 - TheHostname filteruses a regular expression to filter discovered ZUMNET GATEWAYs or JBOXs. Multiple expressions can be applied by using a commato separate the expressions.26 +== Pre-Requisites: == 39 39 40 -Command Syntax: ##"Type='Hostname' Settings='Expr1[,Expr2]'"## 41 - 42 -Examples: 43 - 44 -1. Only include hostnames that start with ZUMNET-06: 45 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-06'" 46 -1. Include hostnames that start with ZUMNET-FL01 or contain FL03: 47 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-FL01,FL03'" 48 - 49 -=== IP Address Filter === 50 - 51 -The IP Address filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP Addresses or IP Address ranges. Multiple addresses and ranges can be used. 52 - 53 -Command Syntax: ##"Type='IPAddress' Settings='Address[,AddressStart-AddressEnd]'"## 54 - 55 -Examples: 56 - 57 -1. Only include a device with an address of 192.168.0.10 or 192.168.0.50: 58 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.10,192.168.0.50'" 59 -1. Include addresses between 192.168.0.11 and 192.168.0.50 and 192.168.0.200 and 192.168.0.240: 60 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.11-192.168.0.50,192.168.0.200-192.168.0.240'" 61 - 62 -=== IP-ID Filter (Added in SR v3.067) === 63 - 64 -The IP-ID filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP-IDs or IP-ID ranges. Multiple IDs and ranges can be used. 65 - 66 -Command Syntax: ##"Type='IPID' Settings='IPID[,IPIDStart-IPIDEnd]'"## 67 - 68 -Examples: 69 - 70 -1. Only include a device with an IP-ID of 10 or 5A: 71 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPID' Settings='10,5A'" 72 -1. Include addresses between 11 and 4F and A0 and BF: 73 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPID' Settings='11-4F,A0-BF'" 74 - 75 -= Zūm Wired Discovery = 76 - 77 -== Notes and Limitations == 78 - 79 -(% class="box warningmessage" %) 80 -((( 81 -* ShowRunnerCLC™ version 3.014 or newer required 82 -* Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 83 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are online prior to running the discovery commands 84 -* Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 85 -* ZUMLINK-IOs will not be discovered (Expected to be discoverable in future ShowRunnerCLC™ release) 86 -* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer will discover keypads and set as remote type) 87 -* One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 28 +* Zum NETBRIDGES acquired to their respective gateway (CEN-GWEXER/ZUMNET-GATEWAY) 29 +* ShowRunner installed and running on a 3-series processor on the same network as the gateway 30 +* NETBRIDGES do not need to have addresses assigned. ShowRunner will automatically address them. If devices all already addressed then their addresses will be honored. 88 88 ))) 89 89 90 -== Steps == 91 - 92 -1. [[Install ShowRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 93 -1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 94 -1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 95 -1*. Connect to the first ZUMNET-JBOX in Toolbox 96 -1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 97 -1**. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 98 -1**. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 99 -1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 100 -1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 101 -1*. Repeat the above steps for all ZUMNET-JBOXs 102 -1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 103 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 104 -1*. Commission room through the app 105 -1**. configure keypad logic 106 -1**. configure occupancy sensor settings 107 -1**. calibrate photocell(s) 108 -1*. Set hostnames for the ZUMNETs. 109 -1**. Zūm discovery will bring in hostnames. 110 -1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 111 -1*. If firmware was out-of-date, then this step should have already been completed 112 -1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 113 -1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 114 -1*. If firmware was out-of-date, then this step should have already been completed 115 -1*. Note: The ShowRunnerCLC™ built-in DHCP server is not meant to be used in production 116 -1*. If the ShowRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 117 -1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 118 -1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 119 -1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 120 -1*. Full control from ShowRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 121 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by ShowRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices 122 -1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 123 -1. If trying to Auto Discover on a job with multiple processors or you are returning to a job where new ZUMNET-JBOXs have been added and you only wish to Auto Discover those new devices, ShowRunnerCLC™ 3.062 and newer allow [[filtering based on hostname or IP address>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome||anchor="HDiscoveryFilter28ShowRunnerCLC21223.062ornewer29"]] in order to limit the devices that are brought into the ShowRunnerCLC™ configuration 124 -1. Run the command: ##sr discover zumnet true true## to add ZUMNET-JBOXs, connected ZUMLINK devices, and some Cresnet devices (such as Cameo keypads) to the configuration. (Note 125 -1*. This command will update the ShowRunnerCLC™ configuration with: 126 -1**. One area per claimed ZUMNET-JBOX based on the Room Name set in the app 127 -1**. One ZUMNET-BRIDGE load controller per claimed ZUMNET-JBOX to allow the Zūm Room to communicate its current status (scene, occupancy, etc.) to ShowRunnerCLC™ 128 -1**. One entry for each ZUMLINK-KP, ZUMLINK-JBOX, and ZUMLINK occupancy sensor connected to each ZUMNET-JBOX 129 -1***. All devices and loads will be auto-labeled based on their connection information, //not// the names they are given in the Zūm App 130 -1***. Keypads will be brought in as "Remote" type and only follow the logic as defined in the Zūm App, allowing for scheduled enabling/disabling of keypads without adding any additional button functions from ShowRunnerCLC™ 131 -1***. Occupancy sensors will be brought in with "Use Hardware Logic" and only follow the logic as defined in the Zūm App 132 -1*. Optionally, run ##sr discover zumnet false true## to only add new ZUMLINK devices to the configuration. **Note that previously added ZUMLINK devices will be added again if their CID has been changed** 133 -1*. Run ##sr discover zumnet true false## to add ZUMNET-JBOXs without bringing in any devices. **Note that if a ZUMNET-JBOX already has an entry in its IP Table, ShowRunnerCLC™ will not claim it.** The ZUMNET-JBOX's IP Table must be cleared in order for it to be claimed by the ShowRunnerCLC™ program 134 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 135 -1. If new Zūm Link hardware has been added, it is not necessary to do a full Auto Discovery to bring the new devices into ShowRunnerCLC™; instead you can just run ##sr discover zumnet false true## to bring in the new Zūm Link devices without claiming any new Zūm Net devices 136 - 137 -= Zūm Wireless Discovery = 138 - 139 -== Notes and Limitations == 140 - 141 -(% class="box warningmessage" %) 33 +(% class="box warningmessage" id="HCaution:" %) 142 142 ((( 143 -* Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 144 -** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 145 -* ZUM-NETBRIDGES must already be acquired to their respective gateway 146 -* ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 147 -* Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 148 -* Plug loads will not appear in the ShowRunnerCLC™ UI 149 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 35 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Autodiscovery 36 + 37 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 38 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 150 150 ))) 151 151 152 -(% class=" box infomessage"id="HCaution:"%)41 +(% class="row" %) 153 153 ((( 154 - **Note:** ShowRunnerCLC™ hastwodifferentapproachesfor ZūmWirelessDiscovery43 +== Option 1: Manual RF Gateway Claiming: == 155 155 156 -1. **Manual RF Gateway Assignment** - ShowRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 157 -1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network. 158 -))) 45 +Use this method if you have multiple ShowRunner instances on the same network or have gateways used by other Crestron systems. 159 159 160 -== Manual RF Gateway Assignment Instructions == 161 - 162 -Use this method if you have multiple ShowRunnerCLC™ instances on the same network or have gateways used by other Crestron systems. 163 - 164 164 * Connect to the processor's console with Toolbox or your favorite SSH client. 165 -* Type ##sr devmgr ethernet query##and press enter. This queries the local network for RF Gateways.166 -* Type ##sr devmgr ethernet show devices##and press enter. This displays all found Crestron ethernet devices.167 -* For each gateway that you'd like this instance of S HOWRUNNER™to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type##sr ethernet device claim CEN-GWEXER-9E6ADA##. ShowRunnerCLC™will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™,proceed to the next step.168 -* Type ##sr discover zummeshfalse##and press enter.169 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 170 -* When the discovery is finished type ##sr save##and press enter to save the updated config.CLC™must be restarted to complete the acquire process.171 -* Type ##progreset##and press enter to restart ShowRunnerCLC™172 -* Once S HOWRUNNER™has finished restarting type##sr discover zummeshfalse##and press enter.CLC™will be able to acquire the loads attached to the Zūm rooms at this point.173 -* Once completed S HOWRUNNER™is now ready for full Zūm control48 +* Type "//sr devmgr ethernet query//" and press enter. This queries the local network for RF Gateways. 49 +* Type "//sr devmgr ethernet show devices//" and press enter. This displays all found Crestron ethernet devices. 50 +* For each gateway that you'd like this instance of ShowRunner to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type "//sr ethernet device claim CEN-GWEXER-9E6ADA//". ShowRunner will auto-assign an IP-ID. After all gateways have been claimed by ShowRunner proceed to the next step. 51 +* Type "//sr discover zum false//" and press enter. 52 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 53 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 54 +* Type "//progreset//" and press enter to restart ShowRunner 55 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 56 +* Once completed ShowRunner is now ready for full Zum control 174 174 175 -== Claim All RFGatewaysInstructions==58 +== Option 2: Claim All Gateways: == 176 176 177 -Use this method when you have a single ShowRunner CLC™instance on a local network with all gateways being used for ShowRunnerCLC™.60 +Use this method when you have a single ShowRunner instance on a local network with all gateways being used for ShowRunner. 178 178 179 179 * Connect to the processor's console with Toolbox or your favorite SSH client. 180 -* Type ##sr discover zummesh true## and press enter. ShowRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step. 181 -* Type ##sr discover zummesh false## and press enter. 182 -* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 183 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunnerCLC™ must be restarted to complete the acquire process. 184 -* Type ##progreset## and press enter to restart ShowRunnerCLC™ 185 -* Once ShowRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point. 186 -* Once completed ShowRunnerCLC™ is now ready for full Zūm control 63 +* Type "//sr discover zum true//" and press enter. 64 +* Status messages and the results will be displayed on the console. The process should take about 3 minutes. 65 +* When the discovery is finished type "//sr save//" and press enter to save the updated config. Due to an unknown quirk that we are looking into, ShowRunner must be restarted to complete the acquire process. 66 +* Type "//progreset//" and press enter to restart ShowRunner 67 +* Once ShowRunner has finished restarting type "//sr discover zum false//" and press enter. ShowRunner will be able to acquire the loads attached to the Zum rooms at this point. 68 +* Once completed ShowRunner is now ready for full Zum control 187 187 188 188 == Examples == 189 189 190 -=== Manual Example === 191 191 73 +=== Example for Option 1: === 74 + 192 192 {{{MC4>sr devmgr ethernet query 193 193 Ethrenet AutoDiscovery Result: AutoDiscoveryOperationSuccess 194 194 MC4>sr devmgr ethernet show devices ... ... @@ -206,7 +206,7 @@ 206 206 MC4>sr ethernet device claim CEN-GWEXER-9E6ADA 207 207 Claimed ethernet device: CEN-GWEXER-9E6ADA 208 208 MC4>Update request from IP-ID-30 in Program 01 209 -MC4>sr discover zum meshfalse92 +MC4>sr discover zum false 210 210 Starting Zum Discovery without gateway claiming 211 211 MC4>Performing Discovery on 1 Gateways. 212 212 Evaluating 3 Devices on Gateway 30 ... ... @@ -239,7 +239,7 @@ 239 239 MC4>progreset 240 240 ... 241 241 CI ShowRunner startup completed successfully in 8072ms 242 -MC4>sr discover zum meshfalse125 +MC4>sr discover zum false 243 243 Starting Zum Discovery without gateway claiming 244 244 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 245 245 Performing Discovery on 1 Gateways. ... ... @@ -290,9 +290,9 @@ 290 290 Removed Loads: 0 291 291 Zum Discovery Finished}}} 292 292 293 -=== Claim AllExample ===176 +=== Example for Option 2: === 294 294 295 -{{{MC4>sr discover zum meshtrue178 +{{{MC4>sr discover zum true 296 296 Starting Zum Discovery with gateway claiming 297 297 MC4>Found 1 Gateways to check. 298 298 Claimed Gateway SN: 1720JBH04269 at IP-ID: 30 ... ... @@ -328,7 +328,7 @@ 328 328 MC4>progreset 329 329 ... 330 330 CI ShowRunner startup completed successfully in 8072ms 331 -MC4>sr discover zum meshfalse214 +MC4>sr discover zum false 332 332 Starting Zum Discovery without gateway claiming 333 333 MC4>Notice: SimplSharpPro[App01] # 2020-07-21 22:19:46 # Recalling startup scenes (if applicable) 334 334 Performing Discovery on 1 Gateways. ... ... @@ -379,3 +379,4 @@ 379 379 Removed Loads: 0 380 380 Zum Discovery Finished 381 381 }}} 265 +)))