Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 38.2
edited by Alexander Mott
on 2025/04/03 16:11
on 2025/04/03 16:11
Change comment:
There is no comment for this version
To version 41.1
edited by Austin Weygandt
on 2025/05/02 20:21
on 2025/05/02 20:21
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.austin\.weygandt@chiefintegrations\.com - Content
-
... ... @@ -140,6 +140,7 @@ 140 140 141 141 (% class="box warningmessage" %) 142 142 ((( 143 +* **Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER** 143 143 * Processor with ShowRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 144 144 ** For ShowRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 145 145 * ZUM-NETBRIDGES must already be acquired to their respective gateway ... ... @@ -146,7 +146,6 @@ 146 146 * ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 147 147 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 148 148 * Plug loads will not appear in the ShowRunnerCLC™ UI 149 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 150 150 ))) 151 151 152 152 (% class="box infomessage" id="HCaution:" %) ... ... @@ -157,6 +157,38 @@ 157 157 1. **Claim All RF Gateways** - ShowRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network. 158 158 ))) 159 159 160 +(% class="box errormessage" id="HCaution:" %) 161 +((( 162 +**Note:** Due to what is believed to be an SSL issue, ShowRunnerCLC™ will sometimes fail to acquire Zūm Wireless gateways with the ##sr discover zummesh true## or ##sr ethernet device claim [Hostname]## commands. 163 + 164 +To work around this issue, Zūm Wireless gateways need to be added to the "IpDevices" section of the SrConfig.json and then have their IP Tables manually updated using the ##addm [IP-ID] [Processor IP]## command. Once this has been done, the ##sr discover zummesh false## commands can be run as normal. 165 + 166 +Below is an example "IpDevices" section of a config with three gateways defined. Serial numbers are optional and can be deleted if not known. **Note:** the "IpId" here is decimal, whereas the actual IP-ID that is assigned from Text Console is in hexadecimal. You will need to convert between the two: e.g. decimal "48" corresponds to hexadecimal "30", decimal "74" would correspond to hexadecimal "4A", etc. 167 + 168 +{{{ "Eiscs": [], 169 + "IpDevices": [ 170 + { 171 + "Model": "CEN-GWEXER", 172 + "Name": "GW-1-1", 173 + "SerialNumber": "2402NEJ03956", 174 + "IpId": 48 175 + }, 176 + { 177 + "Model": "CEN-GWEXER", 178 + "Name": "GW-1-2", 179 + "SerialNumber": "2402NEJ03862", 180 + "IpId": 49 181 + }, 182 + { 183 + "Model": "CEN-GWEXER", 184 + "Name": "GW-2-1", 185 + "SerialNumber": "2402NEJ03887", 186 + "IpId": 50 187 + } 188 + ], 189 + "Keyswitches": [],}}} 190 +))) 191 + 160 160 == Manual RF Gateway Assignment Instructions == 161 161 162 162 Use this method if you have multiple ShowRunnerCLC™ instances on the same network or have gateways used by other Crestron systems.