Changes for page Zūm Discovery
Last modified by Alexander Mott on 2025/04/03 17:35
From version 34.1
edited by Mark Kohlmann
on 2024/10/14 22:00
on 2024/10/14 22:00
Change comment:
There is no comment for this version
To version 22.1
edited by Alexander Mott
on 2023/12/08 18:34
on 2023/12/08 18:34
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,14 +1,17 @@ 1 1 (% class="box errormessage" %) 2 2 ((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 5 **WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 6 ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 7 ))) 8 8 7 +(% class="box errormessage" %) 8 +((( 9 +**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 10 +))) 11 + 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide. SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].14 +This article is about automatically building a ShowRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -20,45 +20,6 @@ 20 20 21 21 There are certain pre-requisites and limitations when building a ShowRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 22 22 23 -= Discovery Filter (ShowRunnerCLC™ 3.062 or newer) = 24 - 25 -Discovered ethernet devices may be filtered using either a hostname or IP Address filter. The filter is configured from the command line interface. 26 - 27 -##+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 28 -~| Command | Help | 29 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-| 30 -~| SR discover clear filter | Remove Discovery Filter | 31 -~| SR discover filter | Show Discovery Filter | 32 -~| SR discover filter (X:S) | Set Discovery Filter | 33 -~| - | (X):S:Filter String | 34 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|## 35 - 36 -=== Hostname Filter === 37 - 38 -The Hostname filter uses a regular expression to filter discovered ZUMNET GATEWAYs or JBOXs. Multiple expressions can be applied by using a comma to separate the expressions. 39 - 40 -Command Syntax: ##"Type='Hostname' Settings='Expr1[,Expr2]'"## 41 - 42 -Examples: 43 - 44 -1. Only include hostnames that start with ZUMNET-06: 45 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-06'" 46 -1. Include hostnames that start with ZUMNET-FL01 or contain FL03: 47 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-FL01,FL03'" 48 - 49 -=== IP Address Filter === 50 - 51 -The IP Address filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP Addresses or IP Address ranges. Multiple addresses and ranges can be used. 52 - 53 -Command Syntax: ##"Type='IPAddress' Settings='Address[,AddressStart-AddressEnd]'"## 54 - 55 -Examples: 56 - 57 -1. Only include a device with an address of 192.168.0.10 or 192.168.0.50: 58 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.10,192.168.0.50'" 59 -1. Include addresses between 192.168.0.11 and 192.168.0.50 and 192.168.0.200 and 192.168.0.240: 60 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.11-192.168.0.50,192.168.0.200-192.168.0.240'" 61 - 62 62 = Zūm Wired Discovery = 63 63 64 64 == Notes and Limitations == ... ... @@ -67,10 +67,8 @@ 67 67 ((( 68 68 * ShowRunnerCLC™ version 3.014 or newer required 69 69 * Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 70 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are onlineprior to running the discovery commands34 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 71 71 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 72 -* ZUMLINK-IOs will not be discovered (Expected to be discoverable in future ShowRunnerCLC™ release) 73 -* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer will discover keypads and set as remote type) 74 74 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 75 75 ))) 76 76 ... ... @@ -87,13 +87,7 @@ 87 87 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 88 88 1*. Repeat the above steps for all ZUMNET-JBOXs 89 89 1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 90 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 91 -1*. Commission room through the app 92 -1**. configure keypad logic 93 -1**. configure occupancy sensor settings 94 -1**. calibrate photocell(s) 95 -1*. Set hostnames for the ZUMNETs. 96 -1**. Zūm discovery will bring in hostnames. 52 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 97 97 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 98 98 1*. If firmware was out-of-date, then this step should have already been completed 99 99 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs ... ... @@ -127,7 +127,6 @@ 127 127 * ShowRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 128 128 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 129 129 * Plug loads will not appear in the ShowRunnerCLC™ UI 130 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 131 131 ))) 132 132 133 133 (% class="box infomessage" id="HCaution:" %)