Changes for page Zūm Discovery
Last modified by Austin Weygandt on 2025/05/02 20:21
From version 34.1
edited by Mark Kohlmann
on 2024/10/14 22:00
on 2024/10/14 22:00
Change comment:
There is no comment for this version
To version 13.1
edited by Alexander Mott
on 2022/10/10 23:33
on 2022/10/10 23:33
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Program Configuration.WebHome1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,14 +9,6 @@ 1 -(% class="box errormessage" %) 2 -((( 3 -**IMPORTANT:** When using ShowRunnerCLC™ with a ZUM-HUB4, **do not** discover Zūm Rooms using the Crestron HUB4 Web UI. During discovery, the HUB4 will claim ZUMNET-JBOXs and prevent ShowRunnerCLC™ from auto-discovering or registering the Zūm hardware for itself. 4 - 5 -**WARNING:** Cresnet Discovery is non-functional for ZUMNET-JBOXs with certain versions of Crestron Device Database. 6 -ShowRunnerCLC™ versions v3.019 through v3.041 must be either downgraded to v3.018 or upgraded to v3.042 or newer in order to perform auto-discover functions. 7 -))) 8 - 9 9 (% class="box warningmessage" %) 10 10 ((( 11 -This article is about automatically building a S howRunnerCLC™ configuration using the Zūm Discovery feature of ShowRunnerCLC™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Zūm App Overview.WebHome]].3 +This article is about automatically building a SHOWRUNNER™ configuration using the Zūm Discovery feature of SHOWRUNNER™. For instructions on configuring Zūm Wired rooms using the Crestron Zūm App, see [[this page>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]]. 12 12 For instructions on configuring Zūm Net devices using Crestron Toolbox, see [[this page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]. 13 13 ))) 14 14 ... ... @@ -16,154 +16,105 @@ 16 16 {{toc/}} 17 17 {{/box}} 18 18 19 -If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a S howRunnerCLC™ configuration file using the Zūm Discovery feature that is built into ShowRunnerCLC™.11 +If Zūm Wired or Wireless devices have been configured using Crestron's Zūm App, then it is possible to automatically build a SHOWRUNNER™ configuration file using the Zūm Discovery feature that is built into SHOWRUNNER™. 20 20 21 -There are certain pre-requisites and limitations when building a S howRunnerCLC™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas.13 +There are certain pre-requisites and limitations when building a SHOWRUNNER™ configuration this way, and it may sometimes be necessary make some adjustments to the final configuration, such as changing keypad types and moving loads between areas. 22 22 23 -= Discovery Filter (ShowRunnerCLC™ 3.062 or newer) = 24 - 25 -Discovered ethernet devices may be filtered using either a hostname or IP Address filter. The filter is configured from the command line interface. 26 - 27 -##+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-+ 28 -~| Command | Help | 29 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-| 30 -~| SR discover clear filter | Remove Discovery Filter | 31 -~| SR discover filter | Show Discovery Filter | 32 -~| SR discover filter (X:S) | Set Discovery Filter | 33 -~| - | (X):S:Filter String | 34 -~|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-|## 35 - 36 -=== Hostname Filter === 37 - 38 -The Hostname filter uses a regular expression to filter discovered ZUMNET GATEWAYs or JBOXs. Multiple expressions can be applied by using a comma to separate the expressions. 39 - 40 -Command Syntax: ##"Type='Hostname' Settings='Expr1[,Expr2]'"## 41 - 42 -Examples: 43 - 44 -1. Only include hostnames that start with ZUMNET-06: 45 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-06'" 46 -1. Include hostnames that start with ZUMNET-FL01 or contain FL03: 47 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='Hostname' Settings='^ZUMNET-FL01,FL03'" 48 - 49 -=== IP Address Filter === 50 - 51 -The IP Address filter will restrict discovered ZUMNET GATEWAYs or JBOXs to matching IP Addresses or IP Address ranges. Multiple addresses and ranges can be used. 52 - 53 -Command Syntax: ##"Type='IPAddress' Settings='Address[,AddressStart-AddressEnd]'"## 54 - 55 -Examples: 56 - 57 -1. Only include a device with an address of 192.168.0.10 or 192.168.0.50: 58 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.10,192.168.0.50'" 59 -1. Include addresses between 192.168.0.11 and 192.168.0.50 and 192.168.0.200 and 192.168.0.240: 60 -(% style="font-family:Menlo,Monaco,Consolas,Courier New,monospace; white-space:pre" %)sr discover filter "Type='IPAddress' Settings='192.168.0.11-192.168.0.50,192.168.0.200-192.168.0.240'" 61 - 62 62 = Zūm Wired Discovery = 63 63 64 64 == Notes and Limitations == 65 65 66 -(% class="box warningmessage" %)19 +(% class="box errormessage" %) 67 67 ((( 68 -* S howRunnerCLC™ version 3.014 or newer required21 +* SHOWRUNNER™ version 3.014 or newer required 69 69 * Zūm Wired firmware .puf version 1.02.10 or greater required (ZUMNET-JBOX installed minimum version 1.001.00081) 70 -* Disconnect from any ZUMNET devices you may be connected to in Toolbox and confirm all hardware (NETs and LINKs) are onlineprior to running the discovery commands23 +* Disconnect from any ZUMNET devices you may be connected to in Toolbox prior to running the discovery commands 71 71 * Cresnet devices landed on Zūm Link will not be discovered (Crestron bug expected to be corrected in a future firmware release) 72 -* ZUMLINK-IOs will not be discovered (Expected to be discoverable in future ShowRunnerCLC™ release) 73 -* ZUMLINK-KPs will not be discovered on older versions of ShowRunnerCLC™ (v3.058 or newer will discover keypads and set as remote type) 74 74 * One area will be created per ZUMNET-JBOX; if there are more areas than ZUMNET-JBOXs, additional areas must be created manually 75 75 ))) 76 76 77 77 == Steps == 78 78 79 -1. [[Install S howRunner™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary30 +1. [[Install SHOWRUNNER™>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome]] on the processor and configure the processor as necessary 80 80 1*. Note that while Zūm Wired discovery will build a configuration, if a configuration file was provided then it should still be loaded as it may contain location data or non-Zūm devices. 81 81 1. If the ZUMNET-JBOX firmware is too out-of-date to connect using the Crestron Zūm App, then there are some additional steps required: 82 82 1*. Connect to the first ZUMNET-JBOX in Toolbox 83 83 1*. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 84 -1**. Note: The S howRunnerCLC™ built-in DHCP server is not meant to be used in production85 -1**. If the S howRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses35 +1**. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 36 +1**. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 86 86 1*. Set unique Connection IDs for each device hosted on the ZUMNET-JBOX so that their firmware can be updated 87 87 1*. Load the Zūm Wired firmware to the ZUMNET-JBOX 88 88 1*. Repeat the above steps for all ZUMNET-JBOXs 89 89 1*. Once all the ZUMNET-JBOXs have pushed the new firmware to their hosted devices, disconnect from them in Toolbox and proceed to the next step 90 -1. Connect to each ZUMNET-JBOX in the Crestron Zūm App 91 -1*. Commission room through the app 92 -1**. configure keypad logic 93 -1**. configure occupancy sensor settings 94 -1**. calibrate photocell(s) 95 -1*. Set hostnames for the ZUMNETs. 96 -1**. Zūm discovery will bring in hostnames. 41 +1. Connect to first ZUMNET-JBOX in the Crestron Zūm App 97 97 1. Unique Connection IDs should be automatically assigned to any Zūm Link and Cresnet devices on the ZUMNET-JBOX 98 98 1*. If firmware was out-of-date, then this step should have already been completed 99 99 1*. If unique CIDs are not automatically assigned, connect to the JBOX in Toolbox and give the devices unique CIDs 100 100 1. Configure a static IP address for the ZUMNET-JBOX if there is no DHCP server on the network 101 101 1*. If firmware was out-of-date, then this step should have already been completed 102 -1*. Note: The S howRunnerCLC™ built-in DHCP server is not meant to be used in production103 -1*. If the S howRunnerCLC™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses47 +1*. Note: The SHOWRUNNER™ built-in DHCP server is not meant to be used in production 48 +1*. If the SHOWRUNNER™ built-in DHCP server was used to assign IP addresses to devices, it is still necessary to give those devices static IP addresses 104 104 1. Optionally, manually configure the ZUMNET-JBOX IP table to point at the processor if you want to keep track of which ZUMNET-JBOX is at each IP-ID 105 105 1*. If you do not manually configure the IP table, then SHOWRUNNER™ will automatically configure the IP-ID for each ZUMNET-JBOX during discovery 106 106 1. Set the ZUMNET-JBOX into either Zūm ("App") mode or CNET mode as required for the program 107 -1*. Full control from S howRunnerCLC™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between ShowRunnerCLC™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode108 -1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by S howRunnerCLC™ have static IP addresses and unique CIDs for any hosted devices52 +1*. Full control from SHOWRUNNER™ is only possible if all ZUMNET-JBOXs are in CNET mode. Odd behavior may result from conflicts between SHOWRUNNER™ and internal logic if the ZUMNET-JBOXs are not put into CNET mode 53 +1. Repeat from step 3 until all ZUMNET-JBOXs that are to be controlled by SHOWRUNNER™ have static IP addresses and unique CIDs for any hosted devices 109 109 1. Disconnect from any ZUMNET-JBOXs and then connect to the processor in Toolbox 110 110 1. Run the command: ##sr discover zumnet true false## 111 -1*. This command tells S howRunnerCLC™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration56 +1*. This command tells SHOWRUNNER™ to discover all ZUMMNET-JBOXs on the network, configure their IP tables, and then add corresponding IP Devices to the configuration 112 112 1. Run the command: ##sr discover zumnet true true## 113 -1*. This command tells S howRunnerCLC™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration58 +1*. This command tells SHOWRUNNER™ to discover all Zūm Link hardware (including the internal ZUMNET-JBOX load controller) on the previously discovered Zūm Net devices and then add corresponding areas, loads, sensors, etc. to the configuration 114 114 1**. One area will be created per ZUMNET-JBOX, and all hardware attached to that ZUMNET-JBOX will be assigned to that area 115 115 1*. This command **does not** bring in Cresnet devices: those must be added to the configuration manually until this issue is fixed in the Zūm Wired firmware 116 -1. If all steps have been performed successfully, then you should be able to use the ##sr show area##, ##sr show load##, ##sr show keypad##, and ##sr show occ## commands to see that the ZUMNET and ZUMLINK hardware has been discovered correctly. 117 117 118 118 = Zūm Wireless Discovery = 119 119 120 120 == Notes and Limitations == 121 121 122 -(% class="box warningmessage" %)66 +(% class="box errormessage" %) 123 123 ((( 124 -* Processor with S howRunnerCLC™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired125 -** For S howRunnerCLC™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##**68 +* Processor with SHOWRUNNER™ version 2.190 or newer must be running on the same network as the gateway(s) to be acquired 69 +** For SHOWRUNNER™ versions prior to 3.014 and newer, replace **##sr discover zummesh##** commands with **##sr discover zum##** 126 126 * ZUM-NETBRIDGES must already be acquired to their respective gateway 127 -* S howRunnerCLC™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices71 +* SHOWRUNNER™ will automatically address any ZUM-NETBRIDGES that do not need have addresses assigned, but will still honor any already addressed devices 128 128 * Disconnect from any RF gateways you may be connected to in Toolbox prior to running the discovery command 129 -* Plug loads will not appear in the ShowRunnerCLC™ UI 130 -* Newer GWEXER firmware enables SSL by default. Follow the instructions at [[SSL User Configuration>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.SSL User Configuration.WebHome]] and manually add the IP Table entries on the GWEXER 73 +* Plug loads will not appear in the SHOWRUNNER™ UI 131 131 ))) 132 132 133 -(% class="box in fomessage" id="HCaution:" %)76 +(% class="box warningmessage" id="HCaution:" %) 134 134 ((( 135 -**Note:** S howRunnerCLC™ has two different approaches for Zūm Wireless Discovery78 +**Note:** SHOWRUNNER™ has two different approaches for Zūm Wireless Discovery 136 136 137 -1. **Manual RF Gateway Assignment** - S howRunnerCLC™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network.138 -1. **Claim All RF Gateways** - S howRunnerCLC™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different ShowRunnerCLC™ or other Crestron systems on the same local network.80 +1. **Manual RF Gateway Assignment** - SHOWRUNNER™ can be told which gateways it should scan. Use this approach if you have gateways that are used by multiple systems on the same local network. 81 +1. **Claim All RF Gateways** - SHOWRUNNER™ will find all CEN-GWEXERs [ZUMNET-GATEWAY] on the network and will claim them as its own. **DO NOT** use this method if there are gateways used by different SHOWRUNNER™ or other Crestron systems on the same local network. 139 139 ))) 140 140 141 141 == Manual RF Gateway Assignment Instructions == 142 142 143 -Use this method if you have multiple S howRunnerCLC™ instances on the same network or have gateways used by other Crestron systems.86 +Use this method if you have multiple SHOWRUNNER™ instances on the same network or have gateways used by other Crestron systems. 144 144 145 145 * Connect to the processor's console with Toolbox or your favorite SSH client. 146 146 * Type ##sr devmgr ethernet query## and press enter. This queries the local network for RF Gateways. 147 147 * Type ##sr devmgr ethernet show devices## and press enter. This displays all found Crestron ethernet devices. 148 -* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. S howRunnerCLC™ will auto-assign an IP-ID. After all gateways have been claimed by ShowRunnerCLC™, proceed to the next step.91 +* For each gateway that you'd like this instance of SHOWRUNNER™ to use, use the hostname from the table of found ethernet devices. For example if the gateway Hostname is CEN-GWEXER-9E6ADA type ##sr ethernet device claim CEN-GWEXER-9E6ADA##. SHOWRUNNER™ will auto-assign an IP-ID. After all gateways have been claimed by SHOWRUNNER™, proceed to the next step. 149 149 * Type ##sr discover zummesh false## and press enter. 150 150 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 151 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, S howRunnerCLC™ must be restarted to complete the acquire process.152 -* Type ##progreset## and press enter to restart S howRunnerCLC™153 -* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. S howRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.94 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 95 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 96 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 154 154 * Once completed SHOWRUNNER™ is now ready for full Zūm control 155 155 156 156 == Claim All RF Gateways Instructions == 157 157 158 -Use this method when you have a single S howRunnerCLC™ instance on a local network with all gateways being used for ShowRunnerCLC™.101 +Use this method when you have a single SHOWRUNNER™ instance on a local network with all gateways being used for SHOWRUNNER™. 159 159 160 160 * Connect to the processor's console with Toolbox or your favorite SSH client. 161 161 * Type ##sr discover zummesh true## and press enter. 162 162 * Status messages and the results will be displayed on the console. The process should take about 3 minutes. 163 -* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, S howRunnerCLC™ must be restarted to complete the acquire process.164 -* Type ##progreset## and press enter to restart S howRunnerCLC™165 -* Once S howRunnerCLC™ has finished restarting type ##sr discover zummesh false## and press enter. ShowRunnerCLC™ will be able to acquire the loads attached to the Zūm rooms at this point.166 -* Once completed S howRunnerCLC™ is now ready for full Zūm control106 +* When the discovery is finished type ##sr save## and press enter to save the updated config. Due to an unknown quirk that we are looking into, SHOWRUNNER™ must be restarted to complete the acquire process. 107 +* Type ##progreset## and press enter to restart SHOWRUNNER™ 108 +* Once SHOWRUNNER™ has finished restarting type ##sr discover zummesh false## and press enter. SHOWRUNNER™ will be able to acquire the loads attached to the Zūm rooms at this point. 109 +* Once completed SHOWRUNNER™ is now ready for full Zūm control 167 167 168 168 == Examples == 169 169